(10360.14072017.115000022) PRIMARY SCHOOL CAVRIGLIA CAPITAL (Q4934367)

From EU Knowledge Graph
Jump to navigation Jump to search
Project Q4934367 in Italy
Language Label Description Also known as
English
(10360.14072017.115000022) PRIMARY SCHOOL CAVRIGLIA CAPITAL
Project Q4934367 in Italy

    Statements

    0 references
    146,529.69 Euro
    0 references
    675,045.31 Euro
    0 references
    21.71 percent
    0 references
    16 November 2018
    0 references
    16 November 2020
    0 references
    COMUNE DI CAVRIGLIA
    0 references
    0 references
    0 references

    43°31'18.73"N, 11°29'20.29"E
    0 references
    TRASFORMAZIONE DELL?EDIFICIO ESISTENTE IN EDIFICIO AD ENERGIA QUASI ZERO (NZEB) COS? COME PREVISTO ALL?ALLEGATO 1 DEL D.M. 26 GIUGNO 2015 ?REQUISITI MINIMI?. NEL DETTAGLIO SI ANDR? AD ESEGUIRE:- COIBENTAZIONE DELLE PARETI PERIMETRALI ATTRAVERSO L?INSTALLAZIONE DI UN CAPPOTTO ESTERNO IN EPS (?=0,034 W/MK, ?=40 KG/M3), DALLO SPESSORE DI 16 CM;- COIBENTAZIONE DELLA COPERTURE DEGLI EDIFICI MEDIANTE USO DI MATERIALI ISOLANTI TALI DA GARANTIRE TRASMITTANZE TERMICHE PARI O INFERIORI A 0,20 W/MQK.- INSTALLAZIONE DI UN SISTEMA DI BUILDING AUTOMATION CON CRONOTERMOSTATO E VALVOLE TERMOSTATICHE WIRELESS SU OGNI CORPO SCALDANTE CON POSSIBILIT? DI TELEGESTIONE DEGLI IMPIANTI DA REMOTO CONFORMEMENTE A QUANTO PREVISTO AL PAR. 5.7.2 DELLE REGOLE APPLICATIVE DEL CONTO TERMICO 2.0;- SOSTITUZIONE DELLE ATTUALI SUPERFICI VETRATE CON SERRAMENTI AVENTI TELAIO IN PVC A 5 CAMERE CAVE E DOPPIA VETROCAMERA 4+4/15/3/15/3+3 CON DOPPIO TRATTAMENTO BASSO EMISSIVO RIEMPITA IN GAS ARGON;- SOSTITUZIONE DEGLI ATTUALI G (Italian)
    0 references
    ПРЕОБРАЗУВАНЕТО НА СЪЩЕСТВУВАЩАТА СГРАДА В СГРАДА С БЛИЗКО ДО НУЛЕВО ПОТРЕБЛЕНИЕ НА ЕНЕРГИЯ (СБННПЕ)? СЪГЛАСНО ПРЕДВИДЕНОТО В ПРИЛОЖЕНИЕ 1 КЪМ МИНИСТЕРСКИЯ УКАЗ ОТ 26 ЮНИ 2015 Г. — МИНИМАЛНИ ИЗИСКВАНИЯ? ПО-ПОДРОБНО, ЩЕ ОТИДЕМ ЛИ? ЗА ИЗВЪРШВАНЕ НА:- ИЗОЛАЦИЯ НА ПЕРИМЕТЪРНИТЕ СТЕНИ ЧРЕЗ МОНТАЖ НА ВЪНШНО EPS ПОКРИТИЕ (?=0.034 W/MK,?=40 KG/M3), С ДЕБЕЛИНА 16 CM;- ИЗОЛАЦИЯ НА ПОКРИВИТЕ НА СГРАДИТЕ ЧРЕЗ ИЗПОЛЗВАНЕ НА ИЗОЛАЦИОННИ МАТЕРИАЛИ, КОИТО ДА ГАРАНТИРАТ ТОПЛОПРОПУСКЛИВОСТ, РАВНА ИЛИ ПО-МАЛКА ОТ 0,20 W/MQK.- МОНТАЖ НА СИСТЕМА ЗА СГРАДНА АВТОМАТИЗАЦИЯ С ХРОНОТЕРМОСТАТНИ И БЕЗЖИЧНИ ТЕРМОСТАТИЧНИ КЛАПАНИ НА ВСЯКО ОТОПЛИТЕЛНО ТЯЛО С ВЪЗМОЖНОСТ? ДИСТАНЦИОННО УПРАВЛЕНИЕ НА СИСТЕМИ В СЪОТВЕТСТВИЕ С ТОЧКА 5.7.2 ОТ ПРАВИЛАТА ЗА ПРИЛАГАНЕ НА ТОПЛИННИЯ ОТЧЕТ 2.0;- ПОДМЯНА НА ТЕКУЩИТЕ ОСТЪКЛЕНИ ПОВЪРХНОСТИ С PVC РАМКИ С 5 КУХИ КАМЕРИ И ДВОЙНО ОСТЪКЛЯВАНЕ 4+ 4/15/3/15/3/3+ 3 С ДВОЙНА ЕМИСИОННА ОБРАБОТКА, ЗАПЪЛНЕНА С АРГОНОВ ГАЗ;- ПОДМЯНА НА ТОКА G (Bulgarian)
    0 references
    PŘEMĚNA STÁVAJÍCÍ BUDOVY NA TÉMĚŘ NULOVOU ENERGETICKOU BUDOVU (NZEB), TAKŽE? JAK JE STANOVENO V PŘÍLOZE 1 MINISTERSKÉ VYHLÁŠKY ZE DNE 26. ČERVNA 2015?MINIMÁLNÍ POŽADAVKY? V DETAILU, POJEDEME? CHCETE-LI PROVÉST:- IZOLACE OBVODOVÝCH STĚN INSTALACÍ VNĚJŠÍHO EPS NÁTĚRU (?=0.034 W/MK,?=40 KG/M3), S TLOUŠŤKOU 16 CM;- IZOLACE STŘECH BUDOV POMOCÍ IZOLAČNÍCH MATERIÁLŮ, KTERÉ ZARUČUJÍ TEPELNÉ PROPUSTNOSTI ROVNAJÍCÍ SE NEBO MENŠÍ NEŽ 0,20 W/MQK.- INSTALACE AUTOMATIZAČNÍHO SYSTÉMU BUDOVY S CHRONOTHERMOSTATEM A BEZDRÁTOVÝMI TERMOSTATICKÝMI VENTILY NA KAŽDÉM TOPNÉM TĚLE S MOŽNOSTÍ? VZDÁLENÁ SPRÁVA SYSTÉMŮ V SOULADU S BODEM 5.7.2 PROVÁDĚCÍCH PRAVIDEL TEPELNÉHO ÚČTU 2.0;- VÝMĚNA STÁVAJÍCÍCH PROSKLENÝCH PLOCH PVC RÁMY 5 DUTÝMI KOMORAMI A DVOJITÝM ZASKLENÍM 4 + 4/15/3/3/3/3 + 3 S DVOJITÝM EMISNÍM ZPRACOVÁNÍM NAPLNĚNÝM ARGONOVÝM PLYNEM;- VÝMĚNA PROUDU G (Czech)
    0 references
    OMDANNELSE AF DEN EKSISTERENDE BYGNING TIL EN NÆSTEN ENERGINEUTRAL BYGNING (NZEB) SÅ? SOM FASTSAT I BILAG 1 TIL MINISTERIELT DEKRET AF 26. JUNI 2015?MINIMUMSKRAV? I DETALJER, VIL VI GÅ? AT UDFØRE:- ISOLERING AF PERIMETERVÆGGE GENNEM INSTALLATION AF EN EKSTERN EPS FRAKKE (? = 0,034 W/MK,? = 40 KG/M3), MED EN TYKKELSE PÅ 16 CM;- ISOLERING AF TAGENE I BYGNINGERNE VED HJÆLP AF ISOLERENDE MATERIALER, SÅSOM AT GARANTERE TERMISKE TRANSMISSIONER LIG MED ELLER MINDRE END 0,20 W/MQK.- INSTALLATION AF ET BYGNINGSAUTOMATISERINGSSYSTEM MED KRONTERMOSTAT OG TRÅDLØSE TERMOSTATVENTILER PÅ HVERT VARMELEGEME MED MULIGHED? FJERNSTYRING AF SYSTEMER I OVERENSSTEMMELSE MED PUNKT 5.7.2 I GENNEMFØRELSESBESTEMMELSERNE FOR TERMISK KONTO 2.0- UDSKIFTNING AF DE NUVÆRENDE RUDER MED PVC-RAMMER MED 5 HULE KAMRE OG DOBBELTRUDER 4+ 4/15/3/15/3+ 3 MED DOBBELT EMISSIV BEHANDLING FYLDT MED ARGONGAS;- UDSKIFTNING AF DEN NUVÆRENDE G (Danish)
    0 references
    UMWANDLUNG DES BESTEHENDEN GEBÄUDES IN EIN NAHEZU NULL-ENERGIEGEBÄUDE (NZEB)? WIE IN ANHANG 1 DES MINISTERIALDEKRETS VOM 26. JUNI 2015 VORGESEHEN?MINDESTANFORDERUNGEN? IM DETAIL, WERDEN WIR GEHEN? DURCHFÜHRUNG:- ISOLIERUNG DER PERIMETERWÄNDE DURCH DEN EINBAU EINER EXTERNEN EPS-BESCHICHTUNG (?=0,034 W/MK,?=40 KG/M3), MIT EINER DICKE VON 16 CM;- ISOLIERUNG DER GEBÄUDEDÄCHER DURCH VERWENDUNG VON ISOLIERMATERIALIEN, UM THERMISCHE DURCHLÄSSIGKEITEN VON 0,20 W/MQK ZU GEWÄHRLEISTEN.- EINBAU EINES GEBÄUDEAUTOMATIONSSYSTEMS MIT CHRONOTHERMOSTAT UND DRAHTLOSEN THERMOSTATISCHEN VENTILEN AN JEDEM HEIZKÖRPER MIT MÖGLICHKEIT? FERNVERWALTUNG VON SYSTEMEN GEMÄSS ABSATZ 5.7.2 DER DURCHFÜHRUNGSBESTIMMUNGEN ZUR WÄRMEBILANZ 2.0;- ERSATZ DER AKTUELLEN VERGLASTEN FLÄCHEN DURCH PVC-RAHMEN DURCH 5 HOHLKAMMERN UND DOPPELVERGLASUNG 4+ 4/15/3/15/3+ 3 DURCH DOPPELT EMISSIVE BEHANDLUNG MIT ARGONGAS GEFÜLLT;- ERSATZ DES STROMS G (German)
    0 references
    ΜΕΤΑΤΡΟΠΉ ΤΟΥ ΥΠΆΡΧΟΝΤΟΣ ΚΤΙΡΊΟΥ ΣΕ ΚΤΊΡΙΟ ΣΧΕΔΌΝ ΜΗΔΕΝΙΚΉΣ ΚΑΤΑΝΆΛΩΣΗΣ ΕΝΈΡΓΕΙΑΣ (NZEB); ΌΠΩΣ ΠΡΟΒΛΈΠΕΤΑΙ ΣΤΟ ΠΑΡΆΡΤΗΜΑ 1 ΤΗΣ ΥΠΟΥΡΓΙΚΉΣ ΑΠΌΦΑΣΗΣ ΤΗΣ 26ΗΣ ΙΟΥΝΊΟΥ 2015 «ΕΛΆΧΙΣΤΕΣ ΑΠΑΙΤΉΣΕΙΣ;» ΑΝΑΛΥΤΙΚΆ, ΘΑ ΠΆΜΕ; ΓΙΑ ΤΗΝ ΕΚΤΈΛΕΣΗ:- ΜΌΝΩΣΗ ΤΩΝ ΠΕΡΙΜΕΤΡΙΚΏΝ ΤΟΙΧΩΜΆΤΩΝ ΜΈΣΩ ΤΗΣ ΕΓΚΑΤΆΣΤΑΣΗΣ ΜΙΑΣ ΕΞΩΤΕΡΙΚΉΣ ΣΤΡΏΣΗΣ EPS (?=0.034 W/MK,?=40 KG/M3), ΜΕ ΠΆΧΟΣ 16 CM;- ΜΌΝΩΣΗ ΤΩΝ ΣΤΕΓΏΝ ΤΩΝ ΚΤΙΡΊΩΝ ΜΕ ΤΗ ΧΡΉΣΗ ΜΟΝΩΤΙΚΏΝ ΥΛΙΚΏΝ, ΈΤΣΙ ΏΣΤΕ ΝΑ ΕΞΑΣΦΑΛΊΖΟΝΤΑΙ ΘΕΡΜΙΚΈΣ ΔΙΑΠΕΡΑΤΌΤΗΤΕΣ ΊΣΕΣ Ή ΜΙΚΡΌΤΕΡΕΣ ΑΠΌ 0,20 W/MQK.- ΕΓΚΑΤΆΣΤΑΣΗ ΣΥΣΤΉΜΑΤΟΣ ΑΥΤΟΜΑΤΙΣΜΟΎ ΚΤΙΡΊΩΝ ΜΕ ΧΡΟΝΟΘΕΡΜΟΣΤΆΤΗ ΚΑΙ ΑΣΎΡΜΑΤΕΣ ΘΕΡΜΟΣΤΑΤΙΚΈΣ ΒΑΛΒΊΔΕΣ ΣΕ ΚΆΘΕ ΘΕΡΜΑΝΤΙΚΌ ΣΏΜΑ ΜΕ ΔΥΝΑΤΌΤΗΤΑ; ΕΞ ΑΠΟΣΤΆΣΕΩΣ ΔΙΑΧΕΊΡΙΣΗ ΣΥΣΤΗΜΆΤΩΝ ΣΎΜΦΩΝΑ ΜΕ ΤΗΝ ΠΑΡΆΓΡΑΦΟ 5.7.2 ΤΩΝ ΚΑΝΌΝΩΝ ΕΦΑΡΜΟΓΉΣ ΤΟΥ ΘΕΡΜΙΚΟΎ ΛΟΓΑΡΙΑΣΜΟΎ 2.0·- ΑΝΤΙΚΑΤΆΣΤΑΣΗ ΤΩΝ ΥΦΙΣΤΑΜΈΝΩΝ ΥΑΛΟΠΙΝΆΚΩΝ ΜΕ ΚΟΥΦΏΜΑΤΑ PVC ΜΕ 5 ΚΟΊΛΟΥΣ ΘΑΛΆΜΟΥΣ ΚΑΙ ΔΙΠΛΟΎΣ ΥΑΛΟΠΊΝΑΚΕΣ 4+ 4/15/3/15/3+ 3 ΜΕ ΔΙΠΛΉ ΕΚΠΕΜΠΌΜΕΝΗ ΕΠΕΞΕΡΓΑΣΊΑ ΓΕΜΙΣΜΈΝΗ ΜΕ ΑΈΡΙΟ ΑΡΓΟΎ·- ΑΝΤΙΚΑΤΆΣΤΑΣΗ ΤΟΥ ΡΕΎΜΑΤΟΣ G (Greek)
    0 references
    TRANSFORMATION OF THE EXISTING BUILDING INTO A NEAR-ZERO ENERGY BUILDING (NZEB) SO? AS PROVIDED FOR IN ANNEX 1 OF THE MINISTERIAL DECREE OF 26 JUNE 2015?MINIMUM REQUIREMENTS? IN DETAIL, WILL WE GO? TO PERFORM:- INSULATION OF THE PERIMETER WALLS THROUGH THE INSTALLATION OF AN EXTERNAL EPS COAT (?=0.034 W/MK,?=40 KG/M3), WITH A THICKNESS OF 16 CM;- INSULATION OF THE ROOFS OF THE BUILDINGS THROUGH THE USE OF INSULATING MATERIALS SUCH AS TO GUARANTEE THERMAL TRANSMITTANCES EQUAL TO OR LESS THAN 0.20 W/MQK.- INSTALLATION OF A BUILDING AUTOMATION SYSTEM WITH CHRONOTHERMOSTAT AND WIRELESS THERMOSTATIC VALVES ON EACH HEATING BODY WITH POSSIBILITY? REMOTE MANAGEMENT OF SYSTEMS IN ACCORDANCE WITH PARAGRAPH 5.7.2 OF THE IMPLEMENTING RULES OF THE THERMAL ACCOUNT 2.0;- REPLACEMENT OF THE CURRENT GLAZED SURFACES WITH PVC FRAMES WITH 5 HOLLOW CHAMBERS AND DOUBLE GLAZING 4+ 4/15/3/15/3+ 3 WITH DOUBLE EMISSIVE TREATMENT FILLED WITH ARGON GAS;- REPLACEMENT OF THE CURRENT G (English)
    0.0686085543481521
    0 references
    ¿TRANSFORMACIÓN DEL EDIFICIO EXISTENTE EN UN EDIFICIO DE ENERGÍA CASI CERO (NZEB) ASÍ? SEGÚN LO DISPUESTO EN EL ANEXO 1 DEL DECRETO MINISTERIAL DE 26 DE JUNIO DE 2015, ¿REQUISITOS MÍNIMOS? EN DETALLE, ¿VAMOS A IR? REALIZAR:- AISLAMIENTO DE LAS PAREDES PERIMETRALES MEDIANTE LA INSTALACIÓN DE UNA CUBIERTA EXTERNA DE EPS (?=0,034 W/MK,?=40 KG/M3), CON UN ESPESOR DE 16 CM;- AISLAMIENTO DE LOS TECHOS DE LOS EDIFICIOS MEDIANTE EL USO DE MATERIALES AISLANTES TALES COMO GARANTIZAR TRANSMITANCIAS TÉRMICAS IGUALES O INFERIORES A 0,20 W/MQK.- INSTALACIÓN DE UN SISTEMA DE AUTOMATIZACIÓN DE EDIFICIOS CON CRONOTERMOSTATO Y VÁLVULAS TERMOSTÁTICAS INALÁMBRICAS EN CADA CUERPO DE CALEFACCIÓN CON POSIBILIDAD? GESTIÓN REMOTA DE SISTEMAS DE CONFORMIDAD CON EL PUNTO 5.7.2 DE LAS NORMAS DE APLICACIÓN DE LA CUENTA TÉRMICA 2.0;- SUSTITUCIÓN DE LAS SUPERFICIES ACRISTALADAS ACTUALES POR MARCOS DE PVC POR 5 CÁMARAS HUECAS Y DOBLE ACRISTALAMIENTO 4+ 4/15/3/15/3+ 3 CON TRATAMIENTO DOBLE EMISIVO LLENO DE GAS ARGÓN;- SUSTITUCIÓN DE LA CORRIENTE G (Spanish)
    0 references
    OLEMASOLEVA HOONE ÜMBEREHITAMINE NULLILÄHEDASEKS HOONEKS (NZEB) NII? NAGU ON ETTE NÄHTUD MINISTRI 26. JUUNI 2015. AASTA DEKREEDI LISAS 1?MIINIMUMNÕUDED? TÄPSEMALT, KAS ME LÄHEME? TÄITA:- ISOLATSIOON PERIMEETRI SEINAD LÄBI PAIGALDAMISE VÄLISE EPS KIHT (?=0,034 W/MK,?=40 KG/M3) PAKSUSEGA 16 CM;- ISOLATSIOON HOONETE KATUSED KASUTADES ISOLEERMATERJALE, ET TAGADA SOOJUSLÄBILASKVUS ON VÕRDNE VÕI VÄIKSEM KUI 0,20 W/MQK.- PAIGALDAMINE HOONE AUTOMAATIKASÜSTEEMI CHRONOTHERMOSTAT JA TRAADITA TERMOSTAATILISED VENTIILID IGAL KÜTTEKEHAL VÕIMALUSEGA? SÜSTEEMIDE KAUGJUHTIMINE VASTAVALT SOOJUSKONTO 2.0 RAKENDUSEESKIRJADE PUNKTILE 5.7.2;- PRAEGUSTE KLAASPINDADE ASENDAMINE PVC-RAAMIDEGA VIIE ÕÕNESKAMBRIGA JA TOPELTKLAASIGA 4+ 4/15/3/15/3+ 3 ARGOONGAASIGA TÄIDETUD KAHEKORDSE EMISSIIVSE TÖÖTLUSEGA;- PRAEGUSE G ASENDAMINE (Estonian)
    0 references
    OLEMASSA OLEVAN RAKENNUKSEN MUUTTAMINEN LÄHES NOLLAENERGIARAKENNUKSEKSI (NZEB)? KUTEN 2015 ANNETUN MINISTERIÖN ASETUKSEN LIITTEESSÄ 1 SÄÄDETÄÄN?VÄHIMMÄISVAATIMUKSET? YKSITYISKOHTAISESTI, LÄHDEMMEKÖ? SUORITTAA:- KEHÄSEINIEN ERISTÄMINEN ASENTAMALLA ULKOINEN EPS-KERROS (?=0,034 W/MK,?=40 KG/M3), JONKA PAKSUUS ON 16 CM;- RAKENNUSTEN KATTOJEN ERISTÄMINEN KÄYTTÄMÄLLÄ ERISTYSMATERIAALEJA, JOTKA TAKAAVAT LÄMMÖNLÄPÄISEVYYDEN 0,20 W/MQK.- RAKENNUKSEN AUTOMAATIOJÄRJESTELMÄN ASENNUS KRONOTHERMOSTATILLA JA LANGATTOMILLA TERMOSTAATTIVENTTIILEILLÄ JOKAISEEN LÄMMITYSRUNKOON MAHDOLLISUUDELLA? JÄRJESTELMIEN ETÄHALLINTA LÄMPÖTILIN 2.0 TÄYTÄNTÖÖNPANOSÄÄNTÖJEN 5.7.2 KOHDAN MUKAISESTI- NYKYISTEN LASIPINTOJEN KORVAAMINEN PVC-KEHYKSILLÄ VIIDELLÄ ONTOLLA KAMMIOLLA JA KAKSOISLASILLA 4+ 4/15/3/15/3/3+ 3 KAKSINKERTAISELLA EMISSIIVE-KÄSITTELYLLÄ, JOKA ON TÄYTETTY ARGONKAASULLA;- NYKYISEN G:N KORVAAMINEN (Finnish)
    0 references
    TRANSFORMATION DU BÂTIMENT EXISTANT EN UN BÂTIMENT ÉNERGÉTIQUE PROCHE DE ZÉRO (NZEB) DONC? COMME PRÉVU À L’ANNEXE 1 DE L’ARRÊTÉ MINISTÉRIEL DU 26 JUIN 2015?EXIGENCES MINIMALES? EN DÉTAIL, ALLONS-NOUS Y ALLER? POUR EFFECTUER:- ISOLATION DES PAROIS PÉRIMÉTRIQUES PAR L’INSTALLATION D’UNE COUCHE EPS EXTERNE (?=0,034 W/MK,?= 40 KG/M3), D’UNE ÉPAISSEUR DE 16 CM;- ISOLATION DES TOITS DES BÂTIMENTS PAR L’UTILISATION DE MATÉRIAUX ISOLANTS DE NATURE À GARANTIR DES TRANSMISSIONS THERMIQUES ÉGALES OU INFÉRIEURES À 0,20 W/MQK.- INSTALLATION D’UN SYSTÈME D’AUTOMATISATION DU BÂTIMENT AVEC CHRONOTHERMOSTAT ET VANNES THERMOSTATIQUES SANS FIL SUR CHAQUE CORPS CHAUFFANT AVEC POSSIBILITÉ? GESTION À DISTANCE DES SYSTÈMES CONFORMÉMENT AU PARAGRAPHE 5.7.2 DES MODALITÉS D’APPLICATION DU COMPTE THERMIQUE 2.0;- REMPLACEMENT DES SURFACES VITRÉES ACTUELLES PAR DES CADRES EN PVC AVEC 5 CHAMBRES CREUSES ET DOUBLE VITRAGE 4+ 4/15/3/15/3+ 3 PAR DOUBLE TRAITEMENT ÉMISSIF REMPLI DE GAZ D’ARGON;- REMPLACEMENT DU COURANT G (French)
    0 references
    AN FOIRGNEAMH ATÁ ANN CHEANA A CHLAOCHLÚ INA FHOIRGNEAMH NACH MÓR NEODRACH Ó THAOBH FUINNIMH DE (NZEB) MAR SIN? MAR A FHORÁILTEAR IN IARSCRÍBHINN 1 A GHABHANN LE FORAITHNE AIREACHTA AN 26 MEITHEAMH 2015?NA HÍOSCHEANGLAIS? GO MION, AN RACHAIDH MUID? A DHÉANAMH: — INSLIÚ AR NA BALLAÍ IMLÍNE TRÍ SHUITEÁIL CÓTA EPS SEACHTRACH (?=0.034 W/MK,? = 40 KG/M3), LE TIÚS DE 16 CM;- INSLIÚ AR DHÍONTA NA BHFOIRGNEAMH TRÍ ÚSÁID A BHAINT AS ÁBHAIR INSLITHE AR NÓS A RÁTHÚ TRANSMITTANCES TEIRMEACH COTHROM LE NÓ NÍOS LÚ NÁ 0.20 W/MQK.- SUITEÁIL CÓRAS UATHOIBRITHE FOIRGNEAMH LE COMHLAÍ CHRONOTHERMOSTAT AGUS GAN SREANG TEIRMEASTATACH AR GACH COMHLACHT TEASA LE FÉIDEARTHACHT? CIANBHAINISTIÚ CÓRAS I GCOMHRÉIR LE MÍR 5.7.2 DE RIALACHA CUR CHUN FEIDHME AN CHUNTAIS THEIRMIGH 2.0;- FRÁMAÍ PVC A CHUR IN IONAD NA NDROMCHLAÍ REATHA GLOINITHE LE 5 CHUASÁN TOLLA AGUS GLOINIÚ DÚBAILTE 4+ 4/15/3/15/3/3+ 3 LE CÓIREÁIL DÍLSITHEACH DHÚBAILTE LÍONTA LE GÁS ARGÓIN;- AN G REATHA A ATHSHOLÁTHAR (Irish)
    0 references
    TRANSFORMACIJA POSTOJEĆE ZGRADE U GOTOVO NULTU ENERGETSKU ZGRADU (NZEB) TAKO? KAKO JE PREDVIĐENO U PRILOGU 1. MINISTARSKOJ UREDBI OD 26. LIPNJA 2015., MINIMALNI ZAHTJEVI? U DETALJE, HOĆEMO LI IĆI? ZA IZVOĐENJE:- IZOLACIJA PERIMETRA ZIDOVA KROZ UGRADNJU VANJSKOG EPS KAPUTA (?=0,034 W/MK,?=40 KG/M3), DEBLJINE 16 CM;- IZOLACIJA KROVOVA ZGRADA KORIŠTENJEM IZOLACIJSKIH MATERIJALA KOJI JAMČE TOPLINSKU PROPUSNOST JEDNAKA ILI MANJA OD 0,20 W/MQK.- INSTALACIJA SUSTAVA AUTOMATIZACIJE ZGRADE S KRONOTERMOSTATSKIM I BEŽIČNIM TERMOSTATSKIM VENTILIMA NA SVAKOM GRIJAĆEM TIJELU S MOGUĆNOŠĆU? DALJINSKO UPRAVLJANJE SUSTAVIMA U SKLADU SA STAVKOM 5.7.2. PROVEDBENIH PRAVILA TOPLINSKOG RAČUNA 2.0;- ZAMJENA TRENUTNIH OSTAKLJENIH POVRŠINA PVC OKVIRIMA S 5 ŠUPLJIH KOMORA I DVOSTRUKIM OSTAKLJENJEM 4+ 4/15/3/15/3+ 3 DVOSTRUKOM EMISIVNOM OBRADOM ISPUNJENOM ARGONSKIM PLINOM;- ZAMJENA STRUJE G (Croatian)
    0 references
    A MEGLÉVŐ ÉPÜLET ÁTALAKÍTÁSA KÖZEL NULLA ENERGIAIGÉNYŰ ÉPÜLETTÉ (NZEB) TEHÁT? A 2015. JÚNIUS 26-I MINISZTERI RENDELET 1. MELLÉKLETÉBEN ELŐÍRTAK SZERINT?MINIMÁLIS KÖVETELMÉNYEK? RÉSZLETESEN, MEGYÜNK? A PEREMFALAK SZIGETELÉSE KÜLSŐ EPS RÉTEG BEÉPÍTÉSÉVEL (?=0,034 W/MK,?=40 KG/M3), 16 CM VASTAGSÁGÚ;- AZ ÉPÜLETEK TETŐINEK SZIGETELÉSE OLYAN SZIGETELŐANYAGOKKAL, AMELYEK BIZTOSÍTJÁK A 0,20 W/MQK-NAK MEGFELELŐ VAGY ANNÁL KISEBB HŐÁTERESZTÉST- ÉPÜLETAUTOMATIZÁLÁSI RENDSZER BEÉPÍTÉSE KRONOTHERMOSTÁTTAL ÉS VEZETÉK NÉLKÜLI TERMOSZTATIKUS SZELEPEKKEL MINDEN EGYES FŰTŐTESTRE LEHETSÉGES? RENDSZEREK TÁVIRÁNYÍTÁSA A 2.0 TERMIKUS SZÁMLA VÉGREHAJTÁSI SZABÁLYAINAK 5.7.2. SZAKASZA SZERINT;- AZ AKTUÁLIS ÜVEGEZETT FELÜLETEK CSERÉJE PVC KERETEKKEL 5 ÜREGES KAMRÁVAL ÉS KETTŐS ÜVEGEZÉS 4+ 4/15/3/15/3+ 3 KETTŐS ÜVEGEZÉSSEL ARGONGÁZZAL TÖLTÖTT KETTŐS KIBOCSÁTÁSÚ KEZELÉSSEL;- AZ ÁRAMERŐSSÉG CSERÉJE (Hungarian)
    0 references
    ESAMO PASTATO TRANSFORMAVIMAS Į BEVEIK NULINĖS ENERGIJOS PASTATĄ (NZEB) TAIP? KAIP NUMATYTA 2015 M. BIRŽELIO 26 D. MINISTRO DEKRETO 1 PRIEDE? IŠSAMIAU, AR EISIME? ATLIKTI:- PERIMETRO SIENŲ IZOLIACIJĄ PER IŠORINIO EPS SLUOKSNIO ĮRENGIMĄ (?=0,034 W/MK,=40 KG/M3), KURIO STORIS 16 CM;- PASTATŲ STOGŲ IZOLIACIJA NAUDOJANT IZOLIACINES MEDŽIAGAS, UŽTIKRINANČIAS NE DIDESNĮ KAIP 0,20 W/MQK ŠILUMINĮ PRALAIDUMĄ – PASTATO AUTOMATIKOS SISTEMOS SU CHRONOTERMOSTATU IR BELAIDŽIAIS TERMOSTATINIAIS VOŽTUVAIS ĮRENGIMAS ANT KIEKVIENO ŠILDYMO KORPUSO SU GALIMYBE? NUOTOLINIS SISTEMŲ VALDYMAS PAGAL ŠILUMINĖS SĄSKAITOS 2.0 ĮGYVENDINIMO TAISYKLIŲ 5.7.2 PUNKTĄ;- DABARTINIŲ ĮSTIKLINTŲ PAVIRŠIŲ PAKEITIMAS PVC RĖMAIS SU 5 TUŠČIAVIDURĖMIS KAMEROMIS IR DVIGUBAS STIKLINIMAS 4+ 4/15/3/15/3+ 3 SU DVIGUBU EMISINIU APDOROJIMU, PRIPILDYTU ARGONO DUJŲ;- SROVĖS G PAKEITIMAS (Lithuanian)
    0 references
    ESOŠĀS ĒKAS PĀRVEIDOŠANA PAR GANDRĪZ NULLES ENERĢIJAS ĒKU (NZEB) TĀ? KĀ PAREDZĒTS MINISTRIJAS 2015. GADA 26. JŪNIJA DEKRĒTA 1. PIELIKUMĀ? SĪKĀK, VAI MĒS EJAM? VEIKT:- PERIMETRA SIENU IZOLĀCIJU, UZSTĀDOT ĀRĒJO EPS PĀRKLĀJUMU (?=0,034 W/MK,?=40 KG/M3), AR BIEZUMU 16 CM;- ĒKU JUMTU IZOLĀCIJA, IZMANTOJOT IZOLĀCIJAS MATERIĀLUS, KAS GARANTĒ SILTUMA CAURLAIDĪBU, KAS VIENĀDA AR VAI MAZĀKA PAR 0,20 W/MQK.- ĒKAS AUTOMATIZĀCIJAS SISTĒMAS UZSTĀDĪŠANA AR HRONOTHERMOSTATU UN BEZVADU TERMOSTATA VĀRSTIEM KATRĀ APKURES KORPUSĀ AR IESPĒJU? SISTĒMU ATTĀLINĀTA PĀRVALDĪBA SASKAŅĀ AR TERMISKĀ KONTA 2.0 ĪSTENOŠANAS NOTEIKUMU 5.7.2. PUNKTU;- PAŠREIZĒJO STIKLOTO VIRSMU NOMAIŅA AR PVC RĀMJIEM AR 5 DOBĀM KAMERĀM UN DIVKĀRŠU STIKLOJUMU 4+ 4/15/3/15/3+ 3 AR DUBULTU IZSTAROJOŠU APSTRĀDI, KAS PIEPILDĪTA AR ARGONA GĀZI;- STRĀVAS NOMAIŅA G (Latvian)
    0 references
    IT-TRASFORMAZZJONI TAL-BINI EŻISTENTI F’BINI TA’ KWAŻI ŻERO ENERĠIJA (NZEB) HEKK? KIF PREVIST FL-ANNESS 1 TAD-DIGRIET MINISTERJALI TAS-26 TA’ ĠUNJU 2015?REKWIŻITI MINIMI? FID-DETTALL, SE MMORRU? BIEX IWETTQU: — INSULAZZJONI TAL-ĦITAN TAL-PERIMETRU PERMEZZ TAL-INSTALLAZZJONI TA ‘KISJA EPS ESTERNA (?=0.034 W/MK,?=40 KG/M3), BI ĦXUNA TA’ 16 CM;- INSULAZZJONI TAS-SOQFA TAL-BINI PERMEZZ TAL-UŻU TA ‘MATERJALI IŻOLANTI BĦAL LI JIGGARANTIXXU TRAŻMETTITURI TERMALI UGWALI GĦAL JEW INQAS MINN 0.20 W/MQK.- INSTALLAZZJONI TA’ SISTEMA TA ‘AWTOMAZZJONI TAL-BINI B’VALVOLI KRONOTERMOSTATIĊI U MINGĦAJR FILI FUQ KULL KORP TAT-TISĦIN BIL-POSSIBBILTÀ? ĠESTJONI REMOTA TAS-SISTEMI SKONT IL-PARAGRAFU 5.7.2 TAR-REGOLI TA’ IMPLIMENTAZZJONI TAL-KONT TERMALI 2.0;- SOSTITUZZJONI TAL-UĊUĦ TAL-ĦĠIEĠ ATTWALI B’OQFSA TAL-PVC B’5 KMAMAR VOJTA MINN ĠEWWA U ĦĠIEĠ DOPPJU 4+ 4/15/3/15/3+ 3 BI TRATTAMENT EMISSIV DOPPJU MIMLI BIL-GASS TAL-ARGON;- SOSTITUZZJONI TAL-G ATTWALI (Maltese)
    0 references
    TRANSFORMATIE VAN HET BESTAANDE GEBOUW IN EEN BIJNA NUL ENERGIEGEBOUW (NZEB) DUS? ZOALS BEPAALD IN BIJLAGE 1 BIJ HET MINISTERIEEL BESLUIT VAN 26 JUNI 2015?MINIMUMVEREISTEN? IN DETAIL, ZULLEN WE GAAN? OM UIT TE VOEREN:- ISOLATIE VAN DE OMTREKWANDEN DOOR DE INSTALLATIE VAN EEN EXTERNE EPS-LAAG (?=0.034 W/MK,?=40 KG/M3), MET EEN DIKTE VAN 16 CM;- ISOLATIE VAN DE DAKEN VAN DE GEBOUWEN DOOR HET GEBRUIK VAN ISOLERENDE MATERIALEN DIE THERMISCHE TRANSMISSIES VAN 0,20 W/MQK.- INSTALLATIE VAN EEN GEBOUWAUTOMATISERINGSSYSTEEM MET CHRONOTHERMOSTAT EN DRAADLOZE THERMOSTATISCHE KLEPPEN OP ELK VERWARMINGSLICHAAM MET MOGELIJKHEID GARANDEREN? BEHEER OP AFSTAND VAN SYSTEMEN OVEREENKOMSTIG PUNT 5.7.2 VAN DE UITVOERINGSVOORSCHRIFTEN VAN DE THERMISCHE REKENING 2.0;- VERVANGING VAN DE HUIDIGE GEGLAZUURDE OPPERVLAKKEN DOOR PVC-KOZIJNEN DOOR 5 HOLLE KAMERS EN DUBBELE BEGLAZING 4+ 4/15/3/15/3+ 3 DOOR DUBBELE EMISSIEVE BEHANDELING GEVULD MET ARGONGAS;- VERVANGING VAN DE STROOMG (Dutch)
    0 references
    TRANSFORMAÇÃO DO EDIFÍCIO EXISTENTE NUM EDIFÍCIO ENERGÉTICO QUASE NULO (NZEB) ASSIM? TAL COMO PREVISTO NO ANEXO 1 DO DECRETO MINISTERIAL DE 26 DE JUNHO DE 2015?REQUISITOS MÍNIMOS? EM PORMENOR, VAMOS? REALIZAR:- ISOLAMENTO DAS PAREDES DO PERÍMETRO ATRAVÉS DA INSTALAÇÃO DE UM REVESTIMENTO EXTERNO DE EPS (?=0,034 W/MK,?=40 KG/M3), COM ESPESSURA DE 16 CM;- ISOLAMENTO DOS TELHADOS DOS EDIFÍCIOS ATRAVÉS DO USO DE MATERIAIS ISOLANTES, DE MODO A GARANTIR TRANSMISSÕES TÉRMICAS IGUAIS OU INFERIORES A 0,20 W/MQK.- INSTALAÇÃO DE UM SISTEMA DE AUTOMAÇÃO DE EDIFÍCIOS COM CRONOTERMÓSTATO E VÁLVULAS TERMOSTÁTICAS SEM FIO EM CADA CORPO DE AQUECIMENTO COM POSSIBILIDADE? GESTÃO REMOTA DE SISTEMAS EM CONFORMIDADE COM O PONTO 5.7.2 DAS NORMAS DE EXECUÇÃO DA CONTA TÉRMICA 2.0;- SUBSTITUIÇÃO DAS SUPERFÍCIES ENVIDRAÇADAS DE CORRENTE POR QUADROS DE PVC COM 5 CÂMARAS OCAS E VIDROS DUPLOS 4+4/15/3/15/3+3 COM TRATAMENTO EMISSIVO DUPLO PREENCHIDO COM GÁS DE ARGÔNIO;- SUBSTITUIÇÃO DA CORRENTE G (Portuguese)
    0 references
    TRANSFORMAREA CLĂDIRII EXISTENTE ÎNTR-O CLĂDIRE DE ENERGIE APROAPE ZERO (NZEB) AȘA? ASTFEL CUM SE PREVEDE ÎN ANEXA 1 LA DECRETUL MINISTERIAL DIN 26 IUNIE 2015?CERINȚE MINIME? ÎN DETALIU, MERGEM? PENTRU A EFECTUA:- IZOLAREA PEREȚILOR PERIMETRULUI PRIN INSTALAREA UNUI STRAT EPS EXTERN (?=0,034 W/MK,?=40 KG/M3), CU O GROSIME DE 16 CM;- IZOLAREA ACOPERIȘURILOR CLĂDIRILOR PRIN UTILIZAREA DE MATERIALE IZOLANTE, ASTFEL ÎNCÂT SĂ GARANTEZE TRANSMISII TERMICE EGALE SAU MAI MICI DE 0,20 W/MQK.- INSTALAREA UNUI SISTEM DE AUTOMATIZARE A CLĂDIRII CU CHRONOTHERMOSTAT ȘI SUPAPE TERMOSTATICE WIRELESS PE FIECARE CORP DE ÎNCĂLZIRE CU POSIBILITATE? GESTIONAREA DE LA DISTANȚĂ A SISTEMELOR ÎN CONFORMITATE CU PUNCTUL 5.7.2 DIN NORMELE DE APLICARE A CONTULUI TERMIC 2.0;- ÎNLOCUIREA SUPRAFEȚELOR VITRATE CURENTE CU CADRE DIN PVC CU 5 CAMERE TUBULARE ȘI GEAM DUBLU 4+ 4/15/3/15/3+ 3 CU TRATAMENT DUBLU EMISIV UMPLUT CU GAZ ARGON;- ÎNLOCUIREA CURENTULUI G (Romanian)
    0 references
    TRANSFORMÁCIA EXISTUJÚCEJ BUDOVY NA BUDOVU S TAKMER NULOVOU SPOTREBOU ENERGIE (NZEB)? AKO JE STANOVENÉ V PRÍLOHE 1 MINISTERSKEJ VYHLÁŠKY Z 26. JÚNA 2015?MINIMÁLNE POŽIADAVKY? A ČO SA TÝKA DETAILOV, PÔJDEME? VYKONAŤ:- IZOLÁCIA OBVODOVÝCH STIEN INŠTALÁCIOU VONKAJŠIEHO EPS NÁTERU (?=0,034 W/MK,?=40 KG/M3), S HRÚBKOU 16 CM;- IZOLÁCIA STRIECH BUDOV POMOCOU IZOLAČNÝCH MATERIÁLOV, KTORÉ ZARUČUJÚ TEPELNÚ PRIEPUSTNOSŤ ROVNAJÚCU SA ALEBO MENŠIU AKO 0,20 W/MQK.- INŠTALÁCIA SYSTÉMU AUTOMATIZÁCIE BUDOVY S CHRONOTHERMOSTATOM A BEZDRÔTOVÝMI TERMOSTATICKÝMI VENTILMI NA KAŽDOM VYKUROVACOM TELESE S MOŽNOSŤOU? DIAĽKOVÁ SPRÁVA SYSTÉMOV V SÚLADE S BODOM 5.7.2 VYKONÁVACÍCH PREDPISOV TEPELNÉHO ÚČTU 2.0;- VÝMENA SÚČASNÝCH ZASKLENÝCH PLÔCH ZA PVC RÁMY S 5 DUTÝMI KOMORAMI A DVOJITÝM ZASKLENÍM 4+ 4/15/3/15/3+ 3 S DVOJITÝM EMISÍVNYM SPRACOVANÍM NAPLNENÝM ARGÓNOVÝM PLYNOM;- VÝMENA PRÚDU G (Slovak)
    0 references
    PREOBLIKOVANJE OBSTOJEČE STAVBE V SKORAJ NIČELNO ENERGETSKO STAVBO (NZEB)? KOT JE DOLOČENO V PRILOGI 1 MINISTRSKEGA ODLOKA Z DNE 26. JUNIJA 2015?MINIMALNE ZAHTEVE? V PODROBNOSTIH, BOMO ŠLI? ZA IZVEDBO:- IZOLACIJE OBODNIH STEN Z NAMESTITVIJO ZUNANJEGA EPS PLAŠČA (?=0,034 W/MK?=40 KG/M3), Z DEBELINO 16 CM;- IZOLACIJA STREH STAVB Z UPORABO IZOLACIJSKIH MATERIALOV, KOT JE ZAGOTAVLJANJE TOPLOTNE PREPUSTNOSTI 0,20 W/MQK.- NAMESTITEV SISTEMA ZA AVTOMATIZACIJO STAVB S KRONOTERMOSTATOM IN BREZŽIČNIMI TERMOSTATSKIMI VENTILI NA VSAKEM OGREVALNEM TELESU Z MOŽNOSTJO? DALJINSKO UPRAVLJANJE SISTEMOV V SKLADU Z ODSTAVKOM 5.7.2 IZVEDBENIH PRAVIL TOPLOTNEGA RAČUNA 2.0;- ZAMENJAVA SEDANJIH ZASTEKLJENIH POVRŠIN S PVC OKVIRJI S 5 VOTLIMI KOMORAMI IN DVOJNO ZASTEKLITVIJO 4+4/15/3/15/3+3 Z DVOJNO EMISTIVNO OBDELAVO, NAPOLNJENO Z ARGONSKIM PLINOM;- ZAMENJAVA TOKA G (Slovenian)
    0 references
    OMVANDLING AV DEN BEFINTLIGA BYGGNADEN TILL EN NÄRA NOLL ENERGIBYGGNAD (NZEB) SÅ? I ENLIGHET MED BILAGA 1 TILL MINISTERDEKRETET AV DEN 26 JUNI 2015?MINIMIKRAV? I DETALJ, SKA VI GÅ? ATT UTFÖRA:- ISOLERING AV OMKRETSVÄGGARNA GENOM INSTALLATION AV EN EXTERN EPS-BELÄGGNING (?=0,034 W/MK,?=40 KG/M3), MED EN TJOCKLEK AV 16 CM;- ISOLERING AV BYGGNADERNAS TAK GENOM ANVÄNDNING AV ISOLERINGSMATERIAL SOM GARANTERAR VÄRMETRANSMITTANSER SOM ÄR LIKA MED ELLER MINDRE ÄN 0,20 W/MQK.- INSTALLATION AV ETT BYGGNADSAUTOMATIONSSYSTEM MED KRONOTERMOSTATVENTILER OCH TRÅDLÖSA TERMOSTATVENTILER PÅ VARJE VÄRMEKROPP MED MÖJLIGHET? FJÄRRSTYRNING AV SYSTEM I ENLIGHET MED PUNKT 5.7.2 I TILLÄMPNINGSFÖRESKRIFTERNA FÖR TERMISKT KONTO 2.0.- ERSÄTTNING AV DE AKTUELLA GLASYTORNA MED PVC-RAMAR MED 5 IHÅLIGA KAMMARE OCH DUBBELGLAS 4+ 4/15/3/15/3+ 3 MED DUBBEL EMISSIV BEHANDLING FYLLD MED ARGONGAS.- ERSÄTTNING AV NUVARANDE G (Swedish)
    0 references
    CAVRIGLIA
    0 references
    10 April 2023
    0 references

    Identifiers