“THERMAL MODERNISATION OF THE PRIMARY SCHOOL AND THE LIBRARY IN SIEDLCE TOGETHER WITH THE INSTALLATION OF PHOTOVOLTAIC SYSTEMS, REPLACEMENT OF LIGHTING SYSTEMS AND CENTRAL HEATING RADIATORS — REDUCTION OF LOW EMISSIONS” (Q101897)
Jump to navigation
Jump to search
Project in Poland financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | “THERMAL MODERNISATION OF THE PRIMARY SCHOOL AND THE LIBRARY IN SIEDLCE TOGETHER WITH THE INSTALLATION OF PHOTOVOLTAIC SYSTEMS, REPLACEMENT OF LIGHTING SYSTEMS AND CENTRAL HEATING RADIATORS — REDUCTION OF LOW EMISSIONS” |
Project in Poland financed by DG Regio |
Statements
499,651.84 zloty
0 references
783,143.23 zloty
0 references
84.9 percent
0 references
1 October 2017
0 references
31 December 2018
0 references
GMINA ŁĘCZYCA
0 references
CELEM GŁÓWNYM PROJEKTU JEST: POPRAWA EFEKTYWNOŚCI ENERGETYCZNEJ W SEKTORZE PUBLICZNYM POPRZEZ TERMOMODERNIZACJĘ 2 BUDYNKÓW UŻYTECZNOŚCI PUBLICZNEJ W GMINIE ŁĘCZYCA. BUDYNKI, KTÓRE ZOSTANĄ PODDANE TERMOMODERNIZACJI TO: SZKOŁA PODSTAWOWA IM. ORŁA BIAŁEGO W SIEDLCU DO KTÓREJ UCZĘSZCZA OKOŁO 80 OSÓB ORAZ BIBLIOTEKA W SIEDLCU. PROJEKT BĘDZIE REALIZOWANY W GMINIE ŁĘCZYCA. GRUPĄ DOCELOWĄ PROJEKTU SĄ UCZNIOWIE I PRACOWNICY SZKOŁY PODSTAWOWEJ W SIEDLCU (OKOŁO 92 OSOBY) ORAZ MIESZKAŃCY GMINY ŁĘCZYCA ORAZ POŚREDNIO WSZYSCY MIESZKAŃCY POWIATU ŁĘCZYCKIEGO (ZGODNIE Z DANYMI GUS STAN NA 31.12.2015R. 51 062 OSÓB, GMINA ŁĘCZYCA – 8 530 OSÓB) CZY WOJEWÓDZTWA ŁÓDZKIEGO, KTÓRZY SKORZYSTAJĄ Z EFEKTÓW PROJEKTU, JAKIMI BĘDZIE M.IN. LEPSZY STAN POWIETRZA, SPOWODOWANY OGRANICZENIEM NISKIEJ EMISJI. ZAKRES RZECZOWY PROJEKTU OBEJMUJE: DOCIEPLENIE ŚCIAN ZEWNĘTRZNYCH (BUDYNEK SZKOŁY – BS), DOCIEPLENIE DACHU NAD STRYCHEM NIEUŻYTKOWYM (BS), DOCIEPLENIE STROPODACHU (BS), WYMIANĘ OKIEN ZEWNĘTRZNYCH (BS), WYMIANĘ DRZWI ZEWNĘTRZNYCH (BS), MODERNIZACJA INSTALACJI GRZEWCZEJ (BS), MODERNIZACJA INSTALACJI ELEKTRYCZNEJ - WYMIANA OPRAW OŚWIETLENIOWYCH NA LED (BS), MONTAŻ PANELI FOTOWOLTAICZNYCH (BS), ROBOTY TOWARZYSZĄCE DOCIEPLENIE ŚCIAN ZEWNĘTRZNYCH (BUDYNEK BIBLIOTEKI BB), WYMIANA POKRYCIA DACHOWEGO WRAZ Z NAPRAWĄ WIĘŹBY DACHOWEJ (BB) – KOSZT NIEKWALIFIKOWALNY, W WYNIKU REALIZACJI PROJEKTU WZROŚNIE EFEKTYWNOŚCI ENERGETYCZNA, KTÓRA PO WDROŻENIU PROJEKTU WYNIESIE 41,05 %ŚREDNIA, 41% BS, 41,10% BB. NA POTRZEBY REALIZACJI PROJEKTU ZOSTAŁA OPRAC. DOKUMENTACJA PROJEKTOWA, AUDYTY ENERGETYCZNE. PROJEKT JEST GOTOWY DO WDROŻENIA ZGODNY Z ZASADAMI UNIWERSALNEGO PROJEKTOWANIA: UŻYTECZNOŚĆ DLA OSÓB O RÓŻNEJ SPRAWNOŚCI, ELASTYCZNOŚĆ W UŻYTKOWANIU, PROSTE I INTUICYJNE UŻYTKOWANIE, CZYTELNA INFORMACJA, TOLERANCJA NA BŁĘDY, WYGODNE UŻYTKOWANIE BEZ WYSIŁKU, WIELKOŚĆ I PRZESTRZEŃ ODPOWIEDNIE DLA DOSTĘPU I UŻYTKOWANIA, PERCEPCJA RÓWNOŚCI, STRONA WWW WNIOSKODAWCY – PROSTY INTERFEJS. (Polish)
0 references
Identifiers
RPLD.04.02.02-10-0003/17
0 references