Thermal modernisation of public buildings in Szczaniec Municipality. (Q100302)

From EU Knowledge Graph
Revision as of 10:55, 29 October 2020 by DG Regio (talk | contribs) (‎Removed claim: financed by (P890): Directorate-General for Regional and Urban Policy (Q8361), Removing unnecessary financed by statement)
Jump to navigation Jump to search
Project Q100302 in Poland
Language Label Description Also known as
English
Thermal modernisation of public buildings in Szczaniec Municipality.
Project Q100302 in Poland

    Statements

    0 references
    1,794,401.2 zloty
    0 references
    430,656.29 Euro
    13 January 2020
    0 references
    2,111,060.28 zloty
    0 references
    506,654.47 Euro
    13 January 2020
    0 references
    85.0 percent
    0 references
    10 April 2017
    0 references
    31 December 2019
    0 references
    GMINA SZCZANIEC
    0 references

    52°16'9.5"N, 15°41'7.8"E
    0 references
    Przedmiotem projektu jest głęboka termomodernizacja bud. użyt. publ. w m. Szczaniec: budynek remizy OSP, budynek wykorzystywany do działalności społecznej, budynek przedszkola-przychodni. Projekt obejmuje: ocieplenie przegród poz. i pion.; wymiana okien i/lub drzwi zew.; modern. instalacji c.o. i/lub c.w.u. z wymianą źr. ciepła; zastosowanie wentylacji nawiewno-wywiewnej z odzyskiem ciepła oraz chłodzenia pasywnego, modern. ośw. na LED; montaż inst. fotowoltaicznej i ogrzewania OZE (pomp ciepła w każdym z bud. i dodatkowo kotła na biomasę w Przedszkolu); urządzenia i elektronika systemu zarządzania energią. Gr. docelowe: mieszkańcy G. Szczaniec; użytkownicy budynków: społecznego, OSP, przedszkola; władze G. Szczaniec; intytucje systemu ochrony środ. Gł. cel proj.:Poprawa efektywności energetycznej w sektorze budynków użyteczności publicznej na obszarze G. Szczaniec poprzez optymalizację gospodarki energetycznej w obiektach publicznych w m. Szczaniec. Cele szczeg.:Zmniejszenie zapotrzebowania na energię pierwotną; Redukcja emisji CO; Optymalizacja zużycia e. elektrycznej; Zwiększenie wykorzystania OZE. W. produktu: L. zmodern. energetycznie bud.: 3 szt. Dod. zdolność wytw. e. cieplnej ze źr. odn.: 0,05 MWt Dod. zdolność wytw. e. elektrycznej ze źr. odn.: 0,02 MWe L. podm. wykorzystujących techn. informacyjno-komunikacyjne: 3 szt. L. wyb. jedn. wytw. e. cieplnej z OZE: 3 szt. L. wyb. jedn. wytw. e. elektrycznej z OZE: 3 szt. L. zmodern. źr. ciepła: 3 Szt. Pow. użytkowa bud. poddanych termomodern.: 1291,98 mkw Udz. proj. w odn. do obszaru objętego programem rewitalizacji: 0,69% W. rezultatu: Szac. roczny spadek emisji g. ciepl. (CI 34): 220,59 tony równoważnika CO2/rok Zmn. rocznego zużycia e. pierwotnej w bud. publ.(CI 32): 711 975,98 kWh/rok Il. zaoszcz. e. cieplnej: 2136,00 GJ/rok Il. zaoszcz. e. elektrycznej: 5,87 MWh/rok Zmn. zużycia e. końcowej w wyniku real. proj.: 2136,00 GJ/rok Wzr. zatr.: 1 EPC Wzr. zatr.– kobiety: 0 EPC Wzr. zatr.- mężczyźni: 1 EPC[...] (Polish)
    0 references
    The subject of the project is a deep thermal modernisation of the building. use. publ. in m. Szczaniec: building of the OSP firehouse, building used for social activities, kindergarten and clinic building. The project shall include: warming of partitions and vertical partitions; replacement of windows and/or doors; modern heating and/or hot water installations with heat exchange; application of ventilating and exhaust ventilation with heat recovery and passive cooling, modern LED descent; installation of photovoltaic inst. and RES heating (heat pump in each building and additionally a biomass boiler in kindergarten); equipment and electronics of the energy management system. Target: inhabitants of G. Szczaniec; users of buildings: social, CSR, kindergartens; the authorities of Mr Szczaniec; the intentions of the protection system on Wednesdays. Improving energy efficiency in public buildings in the area of G. Szczaniec by optimising the energy economy in public buildings in Szczaniec. Specific objectives: Reducing primary energy demand; Reduction of CO emissions; Optimisation of electric e.g. consumption; Increase the use of RES. W. product: L. zmodern. energy building: 3 pcs Dod. ability to produce heat from the source: 0,05 MWt Dod. capacity of electrical e.g. source: 0,02 MWe L. subm. using information and communication technology: 3 pcs L. ex. heat e. with RES: 3 pcs L. n. one electric e. e. from RES: 3 pcs L. zmodern. fodder of heat: 3 Piet. Used building materials subjected to thermomodern.: 1291.98 sqm of the project in the area covered by the revitalisation programme: 0,69 % W. of the result: Estimated annual decrease in emissions of g. heat. (CI 34): 220,59 tonnes of CO2 equivalent/year of annual e. primary consumption in publ.(CI 32): 711975,98 kWh/year Il. heat e. e.: 2136,00 GJ/year Il. e. electrical: 5,87 MWh/year Related to final e. consumption as a result of real. project: 2136,00 GJ/year 1 FTE WORK-women: 0 FTE WORK- males: 1 FTE[...] (English)
    16 October 2020
    0 references

    Identifiers

    RPLB.03.02.01-08-0017/18
    0 references