GasEye HydroC — prototype for a laser multi-gas analyser for the global oil and gas market and petrochemical (Q78294)

From EU Knowledge Graph
Revision as of 18:08, 15 July 2020 by DG Regio (talk | contribs) (‎Changed an Item)
Jump to navigation Jump to search
Project in Poland financed by DG Regio
Language Label Description Also known as
English
GasEye HydroC — prototype for a laser multi-gas analyser for the global oil and gas market and petrochemical
Project in Poland financed by DG Regio

    Statements

    0 references
    2,441,062.15 zloty
    0 references
    585,854.916 Euro
    13 January 2020
    0 references
    3,074,380.73 zloty
    0 references
    737,851.3752 Euro
    13 January 2020
    0 references
    79.4 percent
    0 references
    1 September 2015
    0 references
    31 August 2019
    0 references
    AIROPTIC SP. Z O.O.
    0 references
    0 references

    52°24'2.2"N, 16°55'11.3"E
    0 references
    Numer_referencyjny_programu_pomocowego: SA.41471(2015/X) Przeznaczenie_pomocy_publicznej: art. 25 rozporządzenia KE nr 651/2014 z dnia 17 czerwca 2014 r. uznające niektóre rodzaje pomocy za zgodne z rynkiem wewnętrznym w stosowaniu art. 107 i 108 Traktatu (Dz. Urz. UE L 187/1 z 26.06.2014). Głównym celem Projektu jest stworzenie prototypu laserowego multianalizatora gazowego (robocza nazwa GasEye HydroC) celującego w rosnące zapotrzebowanie globalnego rynku naftowo-gazowniczego i petrochemicznego na szybkie, bezobsługowe i precyzyjne urządzenia typu TDLS (z. ang tunable diode laser spectroscopy). Kluczową cechą Gas Eye HydroC w porównaniu do konkurencji będzie zdolność analizy gazów w jednym strumieniu, do tej pory na rynku istnieją tylko instrumenty mierzące jeden gaz jednocześnie Aby osiągnąć zamierzony cel, badania przemysłowe zostały podzielone na trzy etapy. W etapie pierwszym wykonane zostaną prace spektroskopowe w celu opracowania wymagań dla źródeł laserowych. W etapie drugim stworzony zostanie prototyp spektrometru multianalizatora, co wymaga głównie nakładu prac z optoeletroniką i metodami obróbki sygnałów. Opracowana zostanie także metoda autokalibracji multisensora. Równolegle w tym etapie zostanie stworzone prototypowe stanowisko kalibracyjne dla multianalizatora, m.in. zaoparzone w system kalibracji parametrow laserowych i generację skalibrowanych miesznin gazowych. Kamieniem milowym jest prototyp analizatora, który osiągnie założone wartości pomiarowe dla CO2/H2S/H2O w azocie. W etapie trzecim zostaną opracowane metody multipleksowania sygnałów absorpcyjnych oraz metody eliminacji tła spektralnego węglowodorów oraz metoda zapezpieczenia sesnsora do prac w środowisku zagrożonym wybuchem. Kamieniem milowym jest prototyp analizatora, który osiągnnie docelowe wartości limitu detekcji dla CO2/H2S/H2O w warunkach zbliżonych do rzeczywistych, tzn. w gazie ziemnym i w środowisku zagrożonym wybuchem. (Polish)
    0 references
    Reference_reference_programme_aids:SA.41471 (2015/X) _public:Article 25 of Commission Regulation (EC) No 651/2014 of 17 June 2014 declaring certain categories of aid compatible with the internal market in the application of Article 107 and 108 of the Treaty (OJ(OJ LEU L 187/1, 26.06.2014).The main objective of the project is to produce a laser multi-gas analyser (working name GasEye HydroC) with a growing demand for a global gas and gas market for fast, unservicing and precision TDLS types.The key characteristic of Gas Eye C in comparison to competition will be the capacity to analyse gas in a single stream, so far there are only instruments measuring one gas at the same time in the market at the same time in order to achieve the target, the industrial research has been divided into three stages.In the first phase, the spectroscopic work will be carried out to develop requirements for laser sources.In the second phase, a prototype of the spectrometer is created, which mainly requires the input of opto-electronic multimedia and signal processing methods.A method will also be developed for the self-containment of the multisensor.At the same time, a prototype calibration position for multi-analyser will be created, including a vapour calibration system for laser parameters and a generation of calibrated gas bellows.A milestone is a prototype of an analyser that has reached the measured measurement values for CO2/H2S/H2O in nitrogen.In the third phase, methods will be developed for multiplexed absorption signals and methods for the elimination of the background of the spectral hydrocarbon background and the method by which the hydrocarbons are to be baked for work in an explosive atmosphere.A milestone is a prototype of an analyser that achieves detection limit value for CO2/H2S/H2O in similar real-world conditions, i.e. natural gas and an explosive atmosphere. (English)
    0 references

    Identifiers

    POIR.01.01.01-00-0761/15
    0 references