Increase in energy efficiency in the buildings of the Tax Chamber in Katowice — thermal modernisation of the building of the revenue office in Bytomiu (Q84669)

From EU Knowledge Graph
Revision as of 14:15, 22 June 2020 by DG Regio (talk | contribs) (‎Removed claims)
Jump to navigation Jump to search
Project in Poland financed by DG Regio
Language Label Description Also known as
English
Increase in energy efficiency in the buildings of the Tax Chamber in Katowice — thermal modernisation of the building of the revenue office in Bytomiu
Project in Poland financed by DG Regio

    Statements

    0 references
    1,570,403.24 zloty
    0 references
    376,896.7776 Euro
    13 January 2020
    0 references
    85.0 percent
    0 references
    10 November 2016
    0 references
    31 March 2019
    0 references
    IZBA ADMINISTRACJI SKARBOWEJ W KATOWICACH
    0 references
    0 references
    0 references
    Wzrost efektywności energetycznej w budynkach Izby Skarbowej w Katowicach - termomodernizacja budynku użyteczności publicznej Urzędu Skarbowego w Bytomiu, ul. Wrocławska 92 Bytom: modernizacja instalacji c.o., ocieplenie przegród budynku, wymiana oświetlenia na energooszczędne. Zakres prac obejmuje: 1. Opracowanie dokumentacji technicznej termomodernizacji budynku, w tym: - projekt budowlano-wykonawczy,- specyfikacja techniczna wykonania i odbioru robót budowlanych,- przedmiar robót,- kosztorys inwestorski; 2. Roboty budowlano-montażowe: a) modernizacja instalacji c.o. - wymiana grzejników - 149 szt. - montaż zaworów termostatycznych - 149 szt. - wymiana rurociągów i ich izolacja - 1449 m, b) 0cieplenie przegród budynku, - ściany zewnętrzne - 1816,70 m2,- ściany piwnic - 563,80 m2,- strop nad ostatnią kondygnacją - 1094,40 m2,- ocieplenie daszku i piętra - 35,35 m2; c) wymiana oświetlenia na energooszczędne - 570 punktów oświetleniowych, wymiana łączników 177 szt., instalacja odgromowa i uziemień 1kpl., tablica TZU 1szt. (rozdzielnica elektryczna), awaryjne oświetlenie ewakuacyjne (ilość opraw oświetleniowych - 120szt.). Powierzchnia użytkowa budynku wynosi 3015 m2. a powierzchnia wynajmowana na działalność gospodarczą 5,50 m2. Udział powierzchni wynajmowanej w powierzchni użytkowej budynku wynosi 0,19 %. 3. Nadzór inwestorski: a) nadzór nad robotami budowlanymi,b) nadzór autorski; 4. Audyt energetyczny ex-post - 1 kpl; 5.Informacja i promocja: a) tablica informacyjno-pamiątkowa; 6 wydatki niekwalifikowalne; 7 wydatki osobowe. (Polish)
    0 references
    Increase in energy efficiency in the buildings of the Tax Chamber in Katowice — thermal modernisation of the public office of the revenue office in Bytomu, ul.Wrocław 92 Bytom:modernisation of the heating system, insulation of building partitions, replacement of lighting with energy-efficient lighting.This work comprises:1.Development of technical documentation for the thermal renovation of the building, including:Construction and implementation project, — technical specifications for the performance and acceptance of the works, — Bill of quantities, — investment cost estimate;2.Construction and assembly work:modernisation of the heating system — 149 replacement of radiatorsInstallation of thermostatic valves — 149— pipe exchange and their insulation — 1 449 m, (b) 0 insulation of building envelope, — external walls — 1 816.70 m², basement walls — 563.80 m², — ceiling over the last storey — 1 094.40 m², — dszak and the heel — 35.35 m²;(c) replacement of lighting with energy efficient — 570 lighting points, replacement of fittings of 177, ground handling and ground 1kpl., TZU 1szt plate.(electrical switchgear), emergency evacuation lighting (number of luminaires — 120k).The useful floor area of the building is 3 015 m² and the surface area rented for the economic activity of 5.50 m².The floor area of the building is 0.19 %.3.Investor supervision:supervision of construction work, (b) author’s supervision;4.Ex-post energy audit — 1 kpl;5.Information and publicity:(a) Information and souvenir board;6 ineligible expenditure;7 staff expenditure. (English)
    0 references

    Identifiers

    POIS.01.03.01-00-0142/16
    0 references