Construction of a photovoltaic installation at Makofrost (Q4419675)

From EU Knowledge Graph
Revision as of 14:49, 26 October 2022 by DG Regio (talk | contribs) (‎Changed an Item: Import item from Poland)
Jump to navigation Jump to search
Project Q4419675 in Poland
Language Label Description Also known as
English
Construction of a photovoltaic installation at Makofrost
Project Q4419675 in Poland

    Statements

    0 references
    731,628.19 zloty
    0 references
    162,640.95 Euro
    0 references
    1,330,233.08 zloty
    0 references
    295,710.81 Euro
    0 references
    55.0 percent
    0 references
    1 January 2023
    0 references
    31 August 2023
    0 references
    JAROSŁAW MAKOŚ MAKOFROST
    0 references
    0 references

    51°7'44.44"N, 22°0'3.42"E
    0 references
    Budowa instalacji fotowoltaicznej o mocy sumarycznej 396,76 kW Panele fotowoltaiczne 872 sztuki Budowa: Moduł monokrystaliczny Inwertery o mocach dobranych na podstawie projektów technicznych Wykorzystanie przewodów usieciowanych dedykowanych do instalacji fotowoltaicznych typu konstrukcyjnego H1Z2Z2-K, certyfikowanych zgodnie z normą EN 50618 (lub równoważną normą). Ochrona przeciwpożarowa wg PN-HD 60364-4-41 (lub równoważnej) projektuje się samoczynne wyłączenie zasilania zrealizowane poprzez zastosowanie: * Bezpieczników lub wyłączników nadprądowych, * Wyłączników różnicowoprądowych o prądzie zadziałania I n = 30 mA * Instalacje wyrównawcze uziemione * Uziemione konstrukcje stalowe farmy fotowoltaicznej Do celów wprowadzenia mocy do rozdzielnicy stacji planuje się rozdzielnicę RPV(X) i RPV(X), do której przyłączone będą WLZ z instalacji fotowoltaicznej. W części zasilającej projektuje się: * Wyłącznik główny rozdzielnicy - Rozłącznik izolacyjny 3P 630A * SPD Ogranicznik przepięć T1 kombinowany 3P sieć TN-C Iimp=75kA Up≤1,5kV * Przekładniki pomiarowe prądowe 600/5 A/A; 2,5VA; kl.0,5; FS5; Ith-36kA (przekładniki do celów pomiarowych) * Urządzenia kontrolno-pomiarowe * Listwy zaciskowe odpływowe W części odbiorczej planuje się: * 5x rozłącznik bezpiecznikowy listwowy NH2 3P 400A 690VAC szyny 185mm zaciski pryzmowe V (Polish)
    0 references
    Construction of a photovoltaic installation with a total capacity of 396.76 kW Photovoltaic panels 872 pieces Construction: Monocrystalline module Inverters with power selected on the basis of technical projects Use cross-linked wires dedicated to PV installations of the structural type H1Z2Z2-K, certified in accordance with EN 50618 (or equivalent standard). Fire protection according to PN-HD 60364-4-41 (or equivalent) is designed to automatically turn off the power supply realised by using: * Fuses or overcurrent circuit breakers, * Differential current circuit breakers with operation current I n = 30 mA * Ground leveling installations * Grounded steel structures of the photovoltaic farm For the purpose of introducing power to the switchgear of the station, a RPV(X) and RPV(X) switchgear is planned, to which WLZ will be connected from the photovoltaic installation. In the supply part, the following shall be designed: * Main switchgear switch — Insulation switch 3P 630A * SPD Overvoltage limiter T1 combined 3P network TN-C Iimp=75kA Up≤ 1.5kV * 600/5A/A current measuring units; 2.5VA; kl.0,5; FS5; ITH-36kA (measuring gears) * Control and measurement devices * Outflow terminal blocks In the receiving part, it is planned to: * 5x rail fuse disconnector NH2 3P 400A 690VAC rail 185 mm pris clamps V (English)
    21 October 2022
    0 references
    Construction of a photovoltaic installation with a total capacity of 396.76 kW Photovoltaic panels 872 pieces Construction: Monocrystalline module Inverters with power selected on the basis of technical projects Use cross-linked wires dedicated to PV installations of the structural type H1Z2Z2-K, certified in accordance with EN 50618 (or equivalent standard). Fire protection according to PN-HD 60364-4-41 (or equivalent) is designed to automatically turn off the power supply realised by using: * Fuses or overcurrent circuit breakers, * Differential current circuit breakers with operation current I n = 30 mA * Ground leveling installations * Grounded steel structures of the photovoltaic farm For the purpose of introducing power to the switchgear of the station, a RPV(X) and RPV(X) switchgear is planned, to which WLZ will be connected from the photovoltaic installation. In the supply part, the following shall be designed: * Main switchgear switch — Insulation switch 3P 630A * SPD Overvoltage limiter T1 combined 3P network TN-C Iimp=75kA Up≤ 1.5kV * 600/5A/A current measuring units; 2.5VA; kl.0,5; FS5; ITH-36kA (measuring gears) * Control and measurement devices * Outflow terminal blocks In the receiving part, it is planned to: * 5x rail fuse disconnector NH2 3P 400A 690VAC rail 185 mm pris clamps V (English)
    0 references
    WOJ.: LUBELSKIE, POW.: opolski
    0 references
    0 references

    Identifiers

    RPLU.15.01.00-06-0304/22
    0 references