    INTERVENTO 1: COIBENTAZIONE DEL SOLAIO RIVOLTO VERSO SOTTOTETTOL'INTERVENTO PREVEDE L'APPLICAZIONE DI PANNELLI DI POLISTIRENE ESPANSO SINTERIZZATO (EPS, ?=0,033 W/MK, SPESSORE 10 CM). LO SPESSORE SCELTO CONSENTE AL PACCHETTO MURARIO DI RAGGIUNGERE UNA TRASMITTANZA DI 0,25 W/M2K, INFERIORE AL LIMITE PREVISTO DALLA LEGISLAZIONE VIGENTE.INTERVENTO 2: SOSTITUZIONE DELL?INVOLUCRO TRASPARENTEL'INTERVENTO PREVEDE LA SOSTITUZIONE DEGLI INFISSI CON ALTRI PI? PERFORMANTI, CON TELAIO IN PVC (PROFILO VUOTO; CON CINQUE CAMERE CAVE - TRASMITTANZA DEL TELAIO 1,20 W/M?K) E VETRO DOPPIO BASSO EMISSIVO (EMISSIVIT? 0,05; INTERCAPEDINI CON GAS ARGON AL 90%; STRATIGRAFIA 4-20-4 - TRASMITTANZA DELLA PARTE VETRATA 1,20 W/M?K). LA TRASMITTANZA COMPLESSIVA DELL'INFISSO SAR? DI CIRCA 1,5 W/M2K, INFERIORE AL LIMITE PREVISTO DALLA LEGISLAZIONE VIGENTE. INOLTRE, SARANNO PRESENTI ANCHE APERTURE DI TIPO MECCANICO PER SOPPERIRE AD EVENTUALI PROBLEMI DI CONDENSA E RICAMBI D?ARIA. INTERVENTO 3: INSTALLAZIONE DI VALVOLE (Italian)
    0 references
    ACTION 1: 10 INSULATED POLYSTYRENE FOAM PANELS (EPS,? = 0,033 W/MK, CM THICKNESS). THE SELECTED THICKNESS OF THE PACKAGE ALLOWS THE WALL PACKET TO ACHIEVE A TRANSMITTANCE OF 0,25 W/M2K, WHICH IS BELOW THE LIMIT LAID DOWN IN THE LEGISLATION OF 2: DO YOU INTEND TO REPLACE THE TRANSPARENTE-SPOT ENVELOPE WHEN REPLACING THE FIXTURES BY OTHER PI? PROOF OF PERFORMANCE, WITH PVC FRAME (EMPTY; WITH FIVE QUARRIES — TRANSMITTANCE OF CHASSIS 1,20 W/M? K) AND LOW EMISSION GLASS (EMISSIVIT? 0,05; IRON CAVITY WITH 90 % OF THE GASES; STRATIGRAPHY 4-20-4 — LAMP TRANSMITTANCE 1,20 W/M? K). THE OVERALL TRANSMITTANCE OF FIXED SAR EQUIPMENT? ABOUT 1,5 W/M2K, WHICH IS BELOW THE LIMIT PROVIDED FOR IN THE LEGISLATION IN FORCE. IN ADDITION, THERE WILL ALSO BE MECHANICAL OPENINGS TO COVER ANY PROBLEMS OF CONDENSATION AND SPARE PARTS OF AIR. ACTION 3: INSTALLATION OF VALVES (English)