Energy modernisation of public buildings in the village of Kéthely (Q3951271)

From EU Knowledge Graph
Revision as of 04:12, 15 February 2022 by DG Regio (talk | contribs) (‎Removed claims)
Jump to navigation Jump to search
Project Q3951271 in Hungary
Language Label Description Also known as
English
Energy modernisation of public buildings in the village of Kéthely
Project Q3951271 in Hungary

    Statements

    0 references
    0 references
    31 August 2018
    0 references
    28 November 2021
    0 references
    KÉTHELY KÖZSÉG ÖNKORMÁNYZATA
    0 references
    0 references

    46°38'55.82"N, 17°23'52.15"E
    0 references
    A projektben szereplő épületek nem felelnek meg az érvényben lévő energetikai előírások-nak, ezért nem üzemeltethetők gazdaságosan. Azért, hogy a felújítás után az épületek a "CC" mi-nősítést elérjék, a következő műszaki tartalmú beavatkozások történnek: • külső falszerkezetek hőszigetelő vakolatrendszerrel való ellátása, általános helyen 16 cm vastagságú EPS-anyagú hőszigeteléssel, tűzvédelmi elválasztások azonos vastagságú ás-ványgyapot anyagú hőszigeteléssel, a lábazati részeken 12 cm-es XPS hőszigetelő rendszer-rel; • csak az Iskolánál van lapostetős épületrész, itt a lapostető is kap a meglévő rétegrendre épí-tett új 15 cm EPS hőszigetelő rendszert, melyre új PVC-anyagú vízszigetelés kerül; • az attikafalakra a belső oldalakon hőhídmentesítő 10 cm vastagságú EPS-anyagú hőszigete-lést kell beépíteni; • a tetőtéri részeken a tetősíkba (többlet)hőszigetelés beépítése, új belső burkolatok; • padlásfödémeken 3x10 cm ásványgyapot hőszigetelés elterítése; • különféle minőségű és állapotú nyílászárók kibontása után a TNM rendeletnek megfelelő Unyílászáró-értékű nyílászárók beépítése; • szükséges helyeken a padlószerkezetek felújítása, lépésálló EPS hőszigetelés beépítése; • napelemes rendszerek beépítésével a fosszilis energiafogyasztás csökkentése; • hőszivattyús hőtermelő rendszerek beépítésével a fosszilis energiafogyasztás csökkentése; • hőleadó rendszerek korszerűsítése; • az Iskola tornaterme jelenleg hullámpalával fedett, ennek fémlemezre való cserélése, az az-beszt anyagú fedés ártalmatlanítása is megtörténik; • akadálymentes WC-helyiségek kialakítása; • egyéb járulékos szakági munkák (bádogos, villámhárító-szerelés, stb.) (Hungarian)
    0 references
    The buildings included in the project do not comply with the existing energy standards and therefore cannot be operated economically. In order to achieve “CC” after renovation, the following technical interventions are carried out: • provision of thermal insulation plaster systems to external wall structures with 16 cm thickness EPS thermal insulation, fire separations with the same thickness of excavation and mineral wool insulation, 12 cm XPS thermal insulation system on the plinth parts; • only at the School there is a flat roof, here the flat roof also receives the new 15 cm EPS thermal insulation system built on the existing layer, on which new PVC waterproofing will be added; • the attic walls shall be equipped with EPS-material thermal insulation with a thickness of 10 cm on the inner sides; • installation of thermal insulation in the roof plane on the attic parts, new interior coverings; • on attic slabs 3x10 cm mineral wool heat insulation; • after opening doors and windows of different quality and condition, the installation of doors and windows conforming to the Decree of the Minister for Transport; • refurbishment of floor structures in necessary places, installation of step-proof EPS thermal insulation; • reduce fossil energy consumption by installing solar systems; • reduce fossil energy consumption by installing heat pump heat generation systems; • modernisation of heat take-off systems; • the School’s gym is currently covered with corrugated slate, which is replaced by sheet metal and the A-best cover is also disposed of; • the establishment of accessible toilet rooms; • other additional technical works (tinner, lightning rods, etc.) (English)
    9 February 2022
    0 references
    Les bâtiments inclus dans le projet ne sont pas conformes aux normes énergétiques existantes et ne peuvent donc pas être exploités économiquement. Afin de réaliser le «CC» après rénovation, les interventions techniques suivantes sont réalisées: • fourniture de systèmes d’isolation thermique en plâtre aux structures murales extérieures avec isolation thermique EPS de 16 cm d’épaisseur, séparations coupe-feu avec la même épaisseur d’excavation et isolation en laine minérale, système d’isolation thermique de 12 cm XPS sur les pièces du socle; • seulement à l’école il y a un toit plat, ici le toit plat reçoit également le nouveau système d’isolation thermique EPS de 15 cm construit sur la couche existante, sur lequel s’ajoutera une nouvelle étanchéité en PVC; • les parois du grenier doivent être équipées d’une isolation thermique du matériau EPS d’une épaisseur de 10 cm sur les côtés intérieurs; • installation d’isolation thermique dans le plan du toit sur les pièces du grenier, nouveaux revêtements intérieurs; • sur les dalles du grenier 3x10 cm d’isolation thermique en laine minérale; • après avoir ouvert des portes et des fenêtres de qualité et d’état différents, l’installation de portes et de fenêtres conformes à l’arrêté du ministre des Transports; • remise à neuf des structures de plancher dans les endroits nécessaires, installation d’isolation thermique EPS à l’épreuve des étapes; • réduire la consommation d’énergie fossile en installant des systèmes solaires; • réduire la consommation d’énergie fossile en installant des systèmes de production de chaleur par pompe à chaleur; • modernisation des systèmes de décollage de chaleur; • le gymnase de l’école est actuellement recouvert d’ardoise ondulée, qui est remplacée par de la tôle et la meilleure couverture A est également éliminée; • la mise en place de toilettes accessibles; • autres travaux techniques supplémentaires (étain, foudres, etc.) (French)
    10 February 2022
    0 references
    Kéthely, Somogy
    0 references