Complex energy renovation of the Tasner Antal Primary School in Öskü and the municipal office building (Q3950637)
Jump to navigation
Jump to search
Project Q3950637 in Hungary
Language | Label | Description | Also known as |
---|---|---|---|
English | Complex energy renovation of the Tasner Antal Primary School in Öskü and the municipal office building |
Project Q3950637 in Hungary |
Statements
141,195,747.4 forint
0 references
166,112,644.0 forint
0 references
85.0 percent
0 references
1 July 2017
0 references
30 September 2020
0 references
ÖSKÜ KÖZSÉG ÖNKORMÁNYZATA
0 references
A pályázat „Összetett beruházás”, azaz 2 db "Projekt" . A Polgármesteri Hivatal épülete, - Öskü, Szabadságtér 1. (hrsz: 3) -, illetve a Tasner Antal Általános Iskola épülete, - 8191 Öskü, Mecset utca 3., (hrsz: 114,127) –különálló saját mérőhellyel rendelkezik. Az épületek tervezett felújítása energetikus által készített teljes körű energetikai átvizsgálásán alapszik. Az 1. projekt a Tasner Antal Általános Iskola épületének energetikai felújítását tartalmazza. A 2150 m2 fűtött alap-terület iskolaépület jelenlegi energetikai besorolása GG, azaz csak „Átlagost megközelítő” (278,91 %). Indokolt az energetikai felújítás, mivel az összesített energetikai jellemző, az Ep: 233,20 kWh/m2a, míg a követelményértéke, az Epm: 85,00 kWh/m2a. Az épület összesített energetikai jellemzője a követelmény százalékában: 274,36 %. A projektben az 1989-ben átadott lapos tetejű iskola épületének külső határoló szerkezeteinek utólagos hőszigetelése előtt el lesz távolítva a falakat borító 775 m2 palaburkolás is az azbesztmentesítés keretében. A homlokzatok, a lábazatok és a lapostető utólagos hőszigetelése fordított rétegrendben történik. A 135 db elavult, 2,50 W/m2K hő átbocsátási tényezővel bíró fa keretszerkezetű homlokzati üvegezett nyílászárók korszerű, 1,15 W/m2K tényezőjű PVC keretszerkezetű homlokzati üvegezett nyílászárókra lesznek cserélve. Árnyékolni csak a tetőablakot kell, védőfóliával lesz szigetelve. A saját villamosenergia-igény kielégítésére fotovillamos rendszer, 50 kWp teljesítményű napelem rendszer lesz telepítve az épület lapos tetejére statikai számítás alapján. Mivel a számítások alapján a tető terhelhető, ezért betonsúlyozással lesz rögzítve az a napelemeket tartó hordozó szerkezet. A fűtéskorszerűsítés keretében a hagyományos gázkazán lesz lecserélve 98 -105 % hatásfokkal működő kondenzációs kazánra, külső hőmérséklet érzékelővel összekapcsolt szabályozással. A megfelelő állapotban lévő radiátorok hagyományos szelepei lesznek termosztatikus szelepekkel kiváltva. Az iskola világítása elavult, a tantermek világítása általában alulméretezett, a fénycsőarmatúrák rossz hatásfokúak. Az armatúrasorok rossz az elrendezése, sokszor az ablak mellett futnak, alapvetően rossz a kialakításuk és hiányosak. A búrás világítótestek eltérő típusúak, minőségűek. Mivel egységesítésük is indokolt, valamennyi lámpatest elektronikus gyújtással szerelt fénycsöves lámpatestre lesz kicserélve. A projektben az iskola épületének projektarányos akadálymentesítése is megtörténik. Az energetikai beavatkozás eredményeként az épület energetikai besorolása BB lesz. A 2. projekt a Polgármesteri Hivatal épületének energetikai felújítását tartalmazza. A 286 m2 fűtött alap-területű hivatali épület jelenlegi energetikai besorolása HH „Gyenge” (361,53 %). Indokolt az energetikai felújítás, mivel az összesített energetikai jellemző, az Ep: 315,16 kWh/m2a, míg a követelményértéke, az Epm: 85,00 kWh/m2a. Az épület összesített energetikai jellemzője a követelmény százalékában: 350,18 %. A projektben az 1880-ban épült nyeregtetős hivatal épületének külső határoló szerkezeteinek, homlokzati falak, padlásfödém, padlózat, lábazat utólagos hőszigetelése előtt le lesz cserélve azbesztmentesítés keretében a Hivatal tetőzetén az 578 m2 palaborítás, kerámia cserépfedésre. A 24 db külső nyílászáró közül csak 3 db régi, elavult, 3,60 W/m2K hő átbocsátási tényezővel bíró fa keretszerkezetű homlokzati üvegezett nyílászáró. A többi korszerű, 1,15 W/m2K tényezőjű PVC keretszerkezetű homlokzati üvegezett nyílászáró, ezért nem lesznek cserélve. A saját villamosenergia-igény kielégítésére fotovillamos rendszer, 20 kWp teljesítményű napelem rendszer lesz telepítve az épület magas tetejére statikai számítás alapján. A számítások alapján a tető terhelhető. A Hivatalban a teljes fosszilis energiahordozó alapú hőtermelő berendezés ki lesz váltva, cseréje 24 kW –os levegő-víz hőszivattyúra és mindössze 2 db infrapanelre. A jelenlegi hőközlő rendszerre lesz csatlakoztatva a hőszivattyú, mivel a radiátorok műszakilag megfelelőek, csak a hagyományos szelepeik lesznek termosztatikus szelepekkel kiváltva. A hivatal helyiségeinek világítása általában alulméretezett, ezért a korszerű armatúrák által biztosított fényerő-növekedést nem lehet darabszám-csökkentéssel kihasználni. Valamennyi lámpatest elektronikus gyújtással szerelt fénycsöves lámpatestre lesz kicserélve. A Hivatal akadálymentesítése az infokommunikációt kivéve, korábban megtörtént. Az energetikai beavatkozás eredményeként az épület energetikai besorolása AA+ lesz. A 2 projekt fejlesztéseinek eredményeként az üvegházhatású gázok becsült éves csökkenése 77,80 CO2 egyenérték (t) lesz, a megújuló energiaforrásból előállított energiamennyiség 197,95 GJ/év, a A középületek éves primerenergia-fogyasztásának csökkenése 242 621,95 kWh/év, és primer energia felhasználás csökkenés 511,53 GJ lesz. A projekt kezdése 2016. 12. 01. Az összes elszámolható költsége a tartalékkal együtt 166.112.644- Ft. (Hungarian)
0 references
The tender is “Combined investment”, i.e. 2 “Projects”. Building of the Mayor’s Office, — Öskü, Liberty Square 1. (hrs: 3) — and the building of the Tasner Antal Primary School, — 8191 Öskü, 3 Mecset Street, (hrsz: 114,127) — has its own separate measuring area. The planned renovation of the buildings is based on an energetic energy screening. Project 1 includes the energy renovation of the Tasner Antal Primary School building. The current energy classification of the 2 150 m² heated floor-area school building is GG, i.e. only “approximately average” (278.91 %). Energy renovation is justified as the overall energy feature Ep: 233.20 kWh/m2a, while the requirement value, EPM: 85.00 kWh/m2a. Total energy characteristic of the building as a percentage of the requirement: 274.36 %. In the project, 775 m² of slate covering the walls will also be removed in the framework of asbestos removal before the thermal insulation of the outer boundaries of the flat-top school building, which was handed over in 1989. The retrospective thermal insulation of facades, footings and flat roofs is carried out in reverse layers. The 135 outdated façades with wooden frame structure with a heat transfer factor of 2.50 W/m2K will be replaced with modern, 1.15 W/m2K PVC framed façades. You only need to shield the skylight, it will be insulated with protective film. To meet the own electricity demand, a photovoltaic system with a power of 50 kWp will be installed on the flat top of the building based on a static calculation. Since the roof can be loaded on the basis of the calculations, it will be fixed with concrete weighting to the support structure of the solar panels. As part of the heating upgrade, the conventional gas boiler will be replaced by a condensing boiler with an efficiency of 98-105 % with an external temperature sensor connected. Conventional valves for radiators in good condition will be replaced by thermostatic valves. School lighting is outdated, classroom lighting is generally undersised, fluorescent tube armatures are inefficient. Armature rows have a bad layout, often run next to the window, they are basically bad in design and are incomplete. The drilling luminaires are of different types and quality. Since it is also appropriate to standardise all luminaires, all luminaires will be replaced with fluorescent lamps fitted with electronic ignition. In the project, the school building will also be made accessible to the project proportionally. As a result of the energy intervention, the energy classification of the building will be BB. Project 2 includes energy renovation of the building of the Mayor’s Office. The current energy classification of the 286 m² heated office building is HH “Gyenge” (361.53 %). Energy renovation is justified as the overall energy feature Ep: 315.16 kWh/m2a, while the requirement value, EPM: 85.00 kWh/m2a. Total energy characteristic of the building as a percentage of the requirement: 350.18 %. In the project, the external boundaries of the building of the saddle roofing office built in 1880, facade walls, attic floors, floors and posterior thermal insulation will be replaced in the framework of asbestos removal in the framework of the 578 m² palaboration, ceramic tile covering on the roof of the Office. Only 3 of the 24 exterior doors and windows are old, outdated, with a heat transfer factor of 3.60 W/m2K. The other modern, 1,15 W/m2K PVC framed façades are glazed doors and windows, so they will not be replaced. To meet the own electricity demand, a photovoltaic system with a power of 20 kWp will be installed on the high roof of the building based on a static calculation. Based on the calculations, the roof can be loaded. In the Office, the entire fossil fuel-based heating system will be replaced, replaced by 24 kW air-to-water heat pump and only 2 infrared panels. The heat pump will be connected to the current heat transmission system, as the radiators are technically suitable, only their conventional valves will be replaced by thermostatic valves. The lighting of the office’s rooms is generally undersised, so the brightness increases provided by modern armatures cannot be used by reducing the number of units. All luminaires will be replaced with fluorescent lamps equipped with electronic ignition. With the exception of information communication, the Office has been made accessible earlier. As a result of the energy intervention, the energy classification of the building will be AA+. As a result of the development of the 2 projects, the estimated annual reduction of greenhouse gases will be 77.80 CO2 equivalent (t), the amount of energy from renewable sources will be 197.95 GJ/year, the annual primary energy consumption of public buildings will be reduced by 242 621.95 kWh/year, and primary energy consumption will be reduced by 511,53 GJ. Start of the project 2016. 12. 01. The total eligible costs, including the reserve, are HUF 16 612 644. (English)
9 February 2022
0 references
L’offre est «Investissement combiné», c’est-à-dire 2 «projets». Bâtiment du bureau du maire, — Öskü, Place de la Liberté 1. (heures: 3) — et le bâtiment de l’école primaire Tasner Antal, — 8191 Öskü, 3 rue Mecset, (hrsz: 114,127) — a sa propre zone de mesure distincte. La rénovation prévue des bâtiments est basée sur un criblage énergétique énergétique. Le projet 1 comprend la rénovation énergétique du bâtiment de l’école primaire Tasner Antal. La classification énergétique actuelle du bâtiment scolaire de 2 150 m² chauffé au sol est GG, c’est-à-dire seulement «environ la moyenne» (278,91 %). La rénovation énergétique est justifiée par le fait que l’élément énergétique global Ep: 233,20 kWh/m2a, tandis que la valeur requise, EPM: 85,00 kWh/m2a. Énergie totale caractéristique du bâtiment en pourcentage de l’exigence: 274,36 %. Dans le projet, 775 m² d’ardoise couvrant les murs seront également enlevés dans le cadre de l’élimination de l’amiante avant l’isolation thermique des limites extérieures du bâtiment scolaire plat, qui a été remis en 1989. L’isolation thermique rétrospective des façades, des semelles et des toits plats est réalisée en couches inversées. Les 135 façades dépassées avec structure en bois avec un facteur de transfert de chaleur de 2,50 W/m2K seront remplacées par des façades modernes en PVC de 1,15 W/m2K. Vous n’avez qu’à protéger le puits de lumière, il sera isolé avec un film protecteur. Pour répondre à la demande d’électricité propre, un système photovoltaïque d’une puissance de 50 kWp sera installé sur le dessus plat du bâtiment sur la base d’un calcul statique. Comme le toit peut être chargé sur la base des calculs, il sera fixé avec une pondération en béton à la structure de support des panneaux solaires. Dans le cadre de la mise à niveau du chauffage, la chaudière à gaz conventionnelle sera remplacée par une chaudière à condensation d’un rendement de 98-105 % avec un capteur de température externe connecté. Les vannes conventionnelles pour radiateurs en bon état seront remplacées par des vannes thermostatiques. L’éclairage scolaire est dépassé, l’éclairage de classe est généralement sous-dimensionné, les armatures fluorescentes sont inefficaces. Les rangées d’armature ont une mauvaise disposition, souvent exécutées à côté de la fenêtre, elles sont fondamentalement mauvaises dans la conception et sont incomplètes. Les luminaires de forage sont de différents types et de qualité. Puisqu’il est également approprié de normaliser tous les luminaires, tous les luminaires seront remplacés par des lampes fluorescentes équipées d’allumage électronique. Dans le projet, le bâtiment scolaire sera également accessible proportionnellement au projet. À la suite de l’intervention énergétique, la classification énergétique du bâtiment sera BB. Le projet 2 comprend la rénovation énergétique du bâtiment du bureau du maire. La classification énergétique actuelle du bâtiment de bureaux chauffée de 286 m² est HH «Gyenge» (361,53 %). La rénovation énergétique est justifiée par le fait que l’élément énergétique global Ep: 315,16 kWh/m2a, tandis que la valeur requise, EPM: 85,00 kWh/m2a. Énergie totale caractéristique du bâtiment en pourcentage de l’exigence: 350,18 %. Dans le projet, les limites extérieures du bâtiment du bureau de toiture de selle construit en 1880, les murs de façade, les planchers, les planchers et l’isolation thermique postérieure seront remplacés dans le cadre de l’élimination de l’amiante dans le cadre de la palaboration de 578 m², revêtement de carrelage céramique sur le toit de l’Office. Seulement 3 des 24 portes et fenêtres extérieures sont anciennes, obsolètes, avec un facteur de transfert de chaleur de 3,60 W/m2K. Les autres façades en PVC modernes de 1,15 W/m2K sont des portes vitrées et des fenêtres, de sorte qu’elles ne seront pas remplacées. Pour répondre à la demande d’électricité propre, un système photovoltaïque d’une puissance de 20 kWp sera installé sur le haut toit du bâtiment sur la base d’un calcul statique. Sur la base des calculs, le toit peut être chargé. Au sein de l’Office, l’ensemble du système de chauffage à base de combustibles fossiles sera remplacé par une pompe à chaleur air-eau de 24 kW et seulement 2 panneaux infrarouges. La pompe à chaleur sera raccordée au système de transmission de chaleur actuel, étant donné que les radiateurs sont techniquement appropriés, seules les vannes conventionnelles seront remplacées par des vannes thermostatiques. L’éclairage des locaux du bureau est généralement sous-dimensionné, de sorte que la luminosité accrue fournie par les armatures modernes ne peut pas être utilisée en réduisant le nombre d’unités. Tous les luminaires seront remplacés par des lampes fluorescentes équipées d’allumage électronique. À l’exception de la communication d’informations, l’Office a été rendu accessible plus tôt. À la suite de l’intervention énergétique, la classification énergétique du bâtiment sera AA+. À la suite du développement d... (French)
10 February 2022
0 references
Öskü, Veszprém
0 references
Identifiers
TOP-3.2.1-15-VE1-2016-00010
0 references