Installation of solar system at LI-KONT Kft. _x000D_ (Q3935467)

From EU Knowledge Graph
Revision as of 23:02, 14 February 2022 by DG Regio (talk | contribs) (‎Changed an Item: fix budget)
Jump to navigation Jump to search
Project Q3935467 in Hungary
Language Label Description Also known as
English
Installation of solar system at LI-KONT Kft. _x000D_
Project Q3935467 in Hungary

    Statements

    0 references
    7,595,775.0 forint
    0 references
    21,473.26 Euro
    0.002827 Euro
    15 February 2022
    0 references
    13,810,500.0 forint
    0 references
    39,042.28 Euro
    0.002827 Euro
    15 February 2022
    0 references
    55.0 percent
    0 references
    4 January 2021
    0 references
    31 December 2021
    0 references
    LI-KONT Építőipari és Szolgáltató Korlátolt Felelősségű Társaság
    0 references
    0 references

    48°11'25.12"N, 19°39'38.05"E
    0 references
    A fejlesztés keretében az épület tetejére napelemes rendszer kerül telepítésre 49,5kW teljesítménnyel. A várható villamos energia termelés 54 450kWh/év Az új létesítmény általános ismertetése Az épület trapéz lemez tetejére 165 db napelem kerül az 1. számú melléklet elhelyezési rajza alapján. A szolár kábel a napelemek alatt vezetékcsatornában kerül telepítésre. A napelemek által termelt villamos energia a belső 0,4 kV-os hálózatába kerül betáplálásra. Abban az esetben, ha a belső fogyasztás kisebb mint a pillanatnyi termelés, akkor a többlet energia kitáplálásra kerül az ELMŰ hálózatába. Ha a rendszer teljes pillanatnyi fogyasztása kisebb mint a termelés, akkor az ELMŰ hálózatra történő csatlakozási ponton lévő ad-vesz mérő adatai alapján történik az elszámolás. Napelemek: A 300 Wp polykrstályos napelemek egyenként 1650 x 992 x 35 mm méretűek. A beépített 165 db napelem (165 db 300 Wp) összes teljesítménye 49,5 kWp. A beépített napelemek adatlapját a 2. sz. melléklet tartalmazza. Inverterek: Az alkalmazott inverter magas hatásfokú transzformátor nélküli berendezés. Teljesíti az elosztói szabályzatban rögzített szabványok előírásait. Szerkezetek: A ferde tetőre vagy gyártói megfelelőségi bizonylattal, vagy egyedi statikai nyilatkozattal rendelkező rögzítési rendszert lehet alkalmazni. A rögzítő elemek alumíniumból készülnek. Az erőműbe tervezett gépek műszaki paraméterei Napelem Típus: Suntech STP 300-60/Wfh Névleges teljesítmény: (Pmax) 300 W Üresjárási feszültség: (Voc) 39,4 V Rövidzárási áram: (Isc) 9,62 A Munkaponti feszültség: (Vmp) 32,7 V Munkaponti ára: (Imp) 9,18 A Mudolhatásfok: (%) 17,8 % (A fenti paraméterek meghatározása során a megvilágítás 1000 W/m2, cellahőmérséklet 25 °C, AM 1,5.) Inverter Inverterek típusa: SAJ Suntrio Plus 50K DC bemeneti adatok Minimális DC feszültség: 250 V Maximális DC feszültség: 1000 V MPP feszültségtartomány: 280-900 V AC bemeneti adatok Maximális kimeneti áram: 80 A Frekvencia tartomány: 45-65 Hz Teljesítmény tényező (cos ?): 0-1 Hálózati csatlakozás: 3 NPE 400 V/230 V / 3 NPE 380 V/220 V Maximális hatékonyság: 98,8% Euro hatékonyság: 98,5% Éjjeli fogyasztás: < 1 W Védelem foka: IP 65 Általános adatok Méretek (M x SZ x H): 800x550x280 mm Súly: 68 kg Megengedett hőm. tartomány: -25 - +60 °C Megengedett páratartalom: 0-100% A fenti berendezésektől a műszaki egyenértékűség igazolása esetében el lehet térni. Alkalmazott kábel típusok Napelemek egymás közötti és inverterig történő kábelezése: Típus: General Cavi PV1-F UV álló Solar rézkábel Vezető anyaga: Réz (Cu) Szigetelés anyaga: Etilén-propilén gumiszigetelés Külső köpeny: Polipropilén-kaucsuk Vezető ér kialakítása: Sodrott körszelvényű (RM) Feszültség (Uo/U): 600/1000 V Inverterek összekötése a főelosztóval Típus: FG7OR 0,6/1 kV Vezető anyaga: Réz (Cu) Szigetelés anyaga: Kemény etilén-propilén gumiszigetelés Külső köpeny: PVC Vezető ér kialakítása: Sodrott körszelvényű (RM) Feszültség (Uo/U): 600/1000 V Felügyeleti rendszer kialakítása A napelemes rendszer műszaki paramétereit az inverter folyamatosan ellenőrzi. Abban az esetben, ha bármilyen paraméter a megengedett sávon kívülre kerül, akkor hibajelzést ad. Az inverter tartalmaz egy WIFI kártyát, amelyen keresztül kapcsolódik az épület belső internet hálózatához. Az adatgyűjtés az inverteren belül a hálózati kapcsolattól függetlenül folyamatosan történik. (Hungarian)
    0 references
    As part of the development, a solar panel system will be installed on the roof of the building with a capacity of 49.5 kW. The expected electricity production is 54 450 kWh/year General description of the new installation The roof of the building trapezoidal plate is 165 solar panels according to the installation drawing in Annex 1. The solar cable is installed under the solar panels in a duct channel. The electricity produced by solar panels is fed into the internal 0.4 kV network. In case the internal consumption is less than the instantaneous production, the excess energy is fed into the ELMŰ network. If the total instantaneous consumption of the system is less than the production, then the data of the ad-take meter at the connection point to the ELMŰ network will be accounted for. Solar panels: The 300 Wp polykrstantan solar panels are 1650 x 992 x 35 mm each. The built-in 165 solar panels (165 pcs 300 Wp) have a total power of 49.5 kWp. The data sheet for built-in solar panels is set out in Annex 2. Inverters: The inverter used is a device without a high-efficiency transformer. Comply with the standards laid down in the distribution code. Structures: An affixing system with either a manufacturer’s certificate of conformity or a specific static declaration may be applied to the inclined roof. The fastening elements are made of aluminium. Technical parameters of the machines designed for the power plant Solar Panel Type: Suntech STP 300-60/Wfh Rated Power: (Pmax) 300 W idle voltage: (VOC) 39.4 V short circuit current: (ISC) 9.62 The operating voltage: (VMP) 32,7 V working point price: (IMP) 9.18 A Mudol efficiency: (%) 17.8 % (In determining the above parameters the illumination is 1000 W/m², cell temperature 25 °C, AM 1.5.) Inverter Inverter Type: Saj Suntrio Plus 50K DC input data Minimum DC voltage: 250 V Maximum DC voltage: 1000 V MPP voltage range: 280-900 V AC input data Maximum output current: 80 Frequency range: 45-65 Hz Power factor (cos?): 0-1 Network connection: 3 NPE 400 V/230 V/3 NPE 380 V/220 V Maximum efficiency: 98.8 % Euro efficiency: 98.5 % Night Consumption: < 1 W Degree of Protection: IP 65 General data Dimensions (M x R x H): 800x550x280 mm Weight: 68 kg Permissible heat range: —25 to + 60 °C Permissible humidity: 0-100 % Deviation from the above equipment for the demonstration of technical equivalence. Types of cable used to wiring solar panels between themselves and on an inverter: Type: General Cavi PV1-F UV Standing Solar Copper Cable Driving Material: Copper (Cu) Insulation Material: Ethylene propylene rubber insulation External sheath: Polypropylene rubber Leading vein design: Twisted circular section (RM) Voltage (Uo/U): 600/1000 V Connecting Inverters to Main Distributor Type: FG7OR 0.6/1 kV Leading material: Copper (Cu) Insulation Material: Hard ethylene propylene rubber insulation External sheath: PVC Leading vein design: Twisted circular section (RM) Voltage (Uo/U): 600/1000 V Monitoring system design The technical parameters of the solar system are continuously monitored by the inverter. In the event that any parameter is outside the permitted band, it gives an error signal. The inverter includes a WIFI card through which it is connected to the building’s internal internet network. Data is collected continuously within the inverter regardless of the network connection. (English)
    8 February 2022
    0 references
    Dans le cadre du développement, un système de panneaux solaires sera installé sur le toit du bâtiment d’une capacité de 49,5 kW. La production d’électricité prévue est de 54 450 kWh/an Description générale de la nouvelle installation Le toit de la plaque trapézoïdale du bâtiment est de 165 panneaux solaires selon le schéma d’installation figurant à l’annexe 1. Le câble solaire est installé sous les panneaux solaires dans un canal de conduit. L’électricité produite par les panneaux solaires est alimentée dans le réseau interne de 0,4 kV. Si la consommation interne est inférieure à la production instantanée, l’excès d’énergie est injecté dans le réseau ELM. Si la consommation instantanée totale du système est inférieure à la production, on comptabilisera les données du compteur ad-take au point de raccordement au réseau ELM. Panneaux solaires: Les panneaux solaires polykrstantan 300 Wp sont chacun 1650 x 992 x 35 mm. Les 165 panneaux solaires intégrés (165 pcs 300 Wp) ont une puissance totale de 49,5 kWp. La fiche technique relative aux panneaux solaires intégrés figure à l’annexe 2. Onduleurs: L’onduleur utilisé est un dispositif sans transformateur à haut rendement. Respecter les normes fixées dans le code de distribution. Structures: Un système d’apposition avec un certificat de conformité du fabricant ou une déclaration statique spécifique peut être appliqué sur le toit incliné. Les éléments de fixation sont en aluminium. Paramètres techniques des machines conçues pour la centrale électrique Type de panneau solaire: Suntech STP 300-60/Wfh Puissance nominale: (Pmax) tension au ralenti de 300 W: Courant de court-circuit 39,4 V: (ISC) 9.62 La tension de fonctionnement: (VMP) 32,7 V prix du point de travail: (IMP) 9.18 Une efficacité Mudol: (%) 17,8 % (Pour déterminer les paramètres ci-dessus, l’éclairage est de 1000 W/m², température de la cellule 25 °C, AM 1.5.) SAJ SunTrio Plus 50K données d’entrée CC Tension CC minimale: 250 V Tension CC maximale: Plage de tension 1000 V MPP: 280-900 V Données d’entrée AC Courant maximum de sortie: Plage de fréquence 80: 45-65 Hz Facteur de puissance (cos?): 0-1 Connexion réseau: 3 NPE 400 V/230 V/3 NPE 380 V/220 V Efficacité maximale: 98,8 % d’efficacité de l’euro: 98,5 % Consommation nocturne: < 1 W Degré de protection: IP 65 Données générales Dimensions (M x R x H): 800x550x280 mm Poids: 68 kg Gamme de chaleur admissible: —25 à + 60 °C Humidité admissible: 0-100 % Déviation par rapport à l’équipement ci-dessus pour la démonstration de l’équivalence technique. Types de câbles utilisés pour le câblage de panneaux solaires entre eux et sur un onduleur: Type: General Cavi PV1-F UV debout Câble solaire de cuivre Matériau de conduite: Matériau d’isolation en cuivre (Cu): Isolation en caoutchouc d’éthylène propylène gaine extérieure: Caoutchouc polypropylène Conception veineuse principale: Section circulaire torsadée (RM) Tension (Uo/U): 600/1000 V Connexion des inverseurs au distributeur principal Type: FG7OR 0.6/1 kV Matériau principal: Matériau d’isolation en cuivre (Cu): Isolation en caoutchouc d’éthylène propylène dur gaine extérieure: Conception de veine principale en PVC: Section circulaire torsadée (RM) Tension (Uo/U): 600/1000 V Conception du système de surveillance Les paramètres techniques du système solaire sont surveillés en permanence par l’onduleur. Dans le cas où un paramètre se trouve en dehors de la bande autorisée, il donne un signal d’erreur. L’onduleur comprend une carte WIFI par laquelle il est connecté au réseau internet interne du bâtiment. Les données sont collectées en continu dans l’onduleur quelle que soit la connexion réseau. (French)
    10 February 2022
    0 references
    Egyházasgerge, Nógrád
    0 references

    Identifiers

    GINOP-4.1.4-19-2020-02568
    0 references