Construction of a solar system at Autó Baumgartner Kft. (Q3934548)

From EU Knowledge Graph
Revision as of 22:42, 14 February 2022 by DG Regio (talk | contribs) (‎Changed an Item: fix budget)
Jump to navigation Jump to search
Project Q3934548 in Hungary
Language Label Description Also known as
English
Construction of a solar system at Autó Baumgartner Kft.
Project Q3934548 in Hungary

    Statements

    0 references
    0 references
    7,880,590.3 forint
    0 references
    22,278.43 Euro
    0.002827 Euro
    14 February 2022
    0 references
    14,328,346.0 forint
    0 references
    40,506.23 Euro
    0.002827 Euro
    14 February 2022
    0 references
    55.0 percent
    0 references
    23 July 2020
    0 references
    31 July 2021
    0 references
    AUTÓ-BAUMGARTNER Kereskedelmi és Szolgáltató Korlátolt Felelősségű Társaság
    0 references
    0 references

    47°13'44.83"N, 16°37'7.54"E
    0 references
    Az építtető a fenti címen napelemes energiatermelő rendszert kíván kiépíteni. A tervezé - si feladat ezen rendszer villamos engedélyezési tervének elkészítése. Építtető a fenti címen 49,58 kWp névleges teljesítményű napelemes energiatermelő rend szert kíván kiépíteni - A napelemes kiserőmű a létesítmény KIF oldalára csatlakozik, a hálózatra való termeléssel. Így a megtermelt villamos energia gyakorlatilag csak a létesítmény fogyasztás csökkentésére alkalmas. Mivel a rendszer visszatáplál a közcélú hálózatra a létesítése nem építési engedély-köteles tevékenység. Üzembe helyezése a védelmi készülékek koordinációjával, az MSZ EN 50160:2010/A1:2015 Üzemi feszültség: 3F + N, 400/230V, 50 Hz Érintésvédelem: nullázás (TN rendszer +EPH) Napelemes kiserőmű névleges teljesítménye 49,58 kWp 3.1 Napelemek: Az erre kijelölt helyen (lásd: helyszínrajzot) elhelyezett napelemek kapcsai között fény hatására villamos egyenfeszültség jelenik meg. Az alkalmazott napelemek villamos adatai: Megnevezése, Gyártó: Luxor Solar Gmbh Típusa: ECO LINE M72/370 W Névleges teljesítmény (Pmax) 370 [W] Üresjárati feszültség (Voc) 47,58 [V] Rövidzárlati áram (Isc) 10,07 [A] Feszültség max. teljesítmény esetén (Vmp) 39,35 [V] Áramerősség max. teljesítmény esetén (Imp) 9,54 [A] Modul hatásfok (%) 19,66 Csatlakozó MC4 Mennyiség: 134 db A napelemes erőmű számára több terület is használható. A legoptimálisabb a lapos tetős, így az arra épített tartószerkezetre a napelemeket el lehet helyezni. A tető felület héjazata lemeztető, formája trapézlemez. A napelemek rögzítési technológiája: K2 MiniRail sett alumínium sín trapézlemezhez, amit csavarkötéssel rögzítünk a lemezhez. A csavart kültéri, UV álló gumi szigeteléssel ellátott, öntömítő technológia. A sínen MiniClamp MC rögzítővel kerül felrögzítésre a napelem. 3.2 Inverter egység A stringek kapcsain megjelenő egyenfeszültséget több inverter egység alakítja 230/400V 50Hz-es váltakozó feszültséggé, ami szinkronban van az áramszolgáltatói feszültséggel. A be rendezés folyamatosan figyeli és szabályozza a leadott teljesítményt. A berendezés harmonikus torzítása jóval a megengedett érték alatt van, így nem szennyezi a hálózatot. A rendszer teljesen automatikusan üzemel. Amikor az inverter bemenetén a string feszültség eléri a beállított bekapcsolási értéket, az inverter bekapcsol. Hálózati szinkron megszűnése (táplálás kimaradás) esetén az inverter azonnal leválik a hálózatról, zárlatra nem táplál rá, szigetüzemben nem képes működni. Az invertert a hálózattal együttműködő üzemmódra tervezték. A lekapcsolás biztonságossága, ill. a sziget-üzem kialakulásának veszélye érdekében az inverter független megszakító rendszerrel van ellátva. A két egymástól teljesen független galvanikus leválasztást biztosító megszakító rendszer logikailag egymással sorba van kapcsolva. A megszakító rendszer az inverter váltakozó áramú oldalán van elhelyezve, kialakítása olyan, hogy a beépítés helyén fellépő zárlati áramot károsodás nélkül képes elviselni. (Hungarian)
    0 references
    The developer intends to build a solar power generation system at the above address. The design — si task is to prepare the electrical licensing plan for this system. The builder intends to build a solar power generation system with a nominal capacity of 49.58 kWp at the above address — The small solar power plant is connected to the KIF side of the installation, with production to the grid. Thus, the electricity produced is, in practice, only capable of reducing the consumption of the installation. As the system regenerates the public network, the construction of the system is not an activity subject to building permit. Commissioning with the coordination of protective devices, MSZ EN 50160:2010/A1:2015 Operating voltage: 3F + N, 400/230V, 50 Hz Touch protection: zeroing (TN system +EPH) The rated power of a small solar power plant is 49.58 kWp 3.1 Solar panels: At the designated place (see: location drawing) between the terminals of solar panels placed in the light is exposed to electric DC voltage. Electrical data of the solar panels used: Name, Manufacturer: Luxor Solar Gmbh Type: Eco LINE M72/370 W Rated power (Pmax) 370 [W] Empty voltage (Voc) 47.58 [V] Short circuit current (Isc) 10.07 [A] Voltage for max. power (Vmp) 39.35 [V] Current strength (Imp) 9.54 [A] Module efficiency (%) 19.66 Connecting MC4: 134 Pcs The solar power plant can be used in several areas. The most optimal is the flat roof, so the solar panels can be placed on the support structure built on it. The roof surface shellthe plate roof, form trapezoidal plate. Solar panel fastening technology: K2 MiniRail sett for aluminum rail trapezoidal plate, which is fastened to the plate by screw bond. The screw is a self-sealing technology with outdoor UV standing rubber insulation. On the rail, the solar panel is mounted with a MiniClamp MC fastener. 3.2 Inverter unit The DC voltage at the terminals of the strings is converted by several inverter units to an alternating voltage of 230/400V 50 Hz, which is synchronised with the power supply voltage. The setup continuously monitors and controls the output. The harmonic distortion of the equipment is well below the allowed value, so it does not contaminate the network. The system is fully automatic. When the string voltage at the inverter input reaches the set turn-on value, the inverter turns on. In case of network synchronous failure (power outage), the inverter is disconnected immediately from the network, it does not feed it to lockdown, it is not able to operate in isolated operation. The inverter is designed for network-cooperative mode. The inverter is equipped with an independent circuit breaker system to ensure the safety of disconnection and the risk of island operation. The circuit breaker system providing the two completely independent galvanic separations is logically connected to each other. The circuit breaker system is located on the AC side of the inverter and is designed in such a way that it can withstand the fault current at the installation site without damage. (English)
    8 February 2022
    0 references
    Le développeur a l’intention de construire un système de production d’énergie solaire à l’adresse ci-dessus. La tâche de conception — si est de préparer le plan d’autorisation d’électricité pour ce système. Le constructeur a l’intention de construire un système de production d’énergie solaire d’une capacité nominale de 49,58 kWc à l’adresse ci-dessus — La petite centrale solaire est reliée au côté KIF de l’installation, avec production au réseau. Ainsi, l’électricité produite n’est, en pratique, susceptible que de réduire la consommation de l’installation. Comme le système régénère le réseau public, la construction du réseau n’est pas une activité soumise à un permis de construire. Mise en service avec la coordination des dispositifs de protection, MSZ EN 50160:2010/A1:2015 Tension de fonctionnement: 3F + N, 400/230V, 50 Hz Protection tactile: la puissance nominale d’une petite centrale solaire est de 49,58 kWp 3.1 Panneaux solaires: Au lieu désigné (voir: dessin de localisation) entre les bornes des panneaux solaires placés dans la lumière est exposé à la tension électrique CC. Données électriques des panneaux solaires utilisés: Nom, fabricant: Type de Gmbh solaire Luxor: ECO LINE M72/370 W Puissance nominale (Pmax) 370 [W] Tension vide (Voc) 47,58 [V] Courant de court-circuit (Isc) 10,07 [A] Tension pour puissance maximale (Vmp) 39,35 [V] Résistance de courant (Imp) 9,54 [A] Efficacité du module (%) 19.66 Connectage MC4: 134 PC La centrale solaire peut être utilisée dans plusieurs domaines. Le plus optimal est le toit plat, de sorte que les panneaux solaires peuvent être placés sur la structure de support construite sur elle. La coque de la surface du toitLe toit en plaque, forme la plaque trapézoïdale. Technologie de fixation des panneaux solaires: K2 MINIRAIL set pour rail en aluminium plaque trapézoïdale, qui est fixé à la plaque par liaison à vis. La vis est une technologie auto-scellante avec isolation extérieure en caoutchouc UV debout. Sur le rail, le panneau solaire est monté avec une fixation MiniClamp MC. 3.2 Unité inverseur La tension CC aux bornes des cordes est convertie par plusieurs unités d’onduleur en une tension alternative de 230/400V 50 Hz, qui est synchronisée avec la tension d’alimentation. La configuration surveille et contrôle en continu la sortie. La distorsion harmonique de l’équipement est bien inférieure à la valeur autorisée, de sorte qu’il ne contamine pas le réseau. Le système est entièrement automatique. Lorsque la tension de chaîne à l’entrée de l’onduleur atteint la valeur de mise en marche définie, l’onduleur s’allume. En cas de défaillance synchrone du réseau (arrêt de puissance), l’onduleur est déconnecté immédiatement du réseau, il ne l’alimente pas pour le verrouiller, il n’est pas en mesure de fonctionner en fonctionnement isolé. L’onduleur est conçu pour le mode de coopération réseau. L’onduleur est équipé d’un disjoncteur indépendant pour assurer la sécurité de la déconnexion et le risque de fonctionnement de l’îlot. Le système de disjoncteur assurant les deux séparations galvaniques totalement indépendantes est logiquement connecté l’un à l’autre. Le système de disjoncteur est situé du côté AC de l’onduleur et est conçu de telle manière qu’il puisse résister au courant de défaut sur le site d’installation sans endommager. (French)
    10 February 2022
    0 references
    Szombathely, Vas
    0 references

    Identifiers

    GINOP-4.1.4-19-2020-01260
    0 references