Building energy development with the use of renewable energy at Dominó Kft. (Q3925099)

From EU Knowledge Graph
Revision as of 21:46, 14 February 2022 by DG Regio (talk | contribs) (‎Changed an Item: fix budget)
Jump to navigation Jump to search
Project Q3925099 in Hungary
Language Label Description Also known as
English
Building energy development with the use of renewable energy at Dominó Kft.
Project Q3925099 in Hungary

    Statements

    0 references
    0 references
    24,785,015.0 forint
    0 references
    70,067.24 Euro
    0.002827 Euro
    14 February 2022
    0 references
    49,570,030.0 forint
    0 references
    140,134.47 Euro
    0.002827 Euro
    14 February 2022
    0 references
    50.0 percent
    0 references
    10 December 2018
    0 references
    20 May 2020
    0 references
    DOMINÓ Épitőanyagkereskedő és Szolgáltató Korlátolt Felelősségü Társaság
    0 references
    0 references

    46°42'4.97"N, 17°21'58.14"E
    0 references
    A fejlesztés a következő részterületekre terjed ki: Külső hőszigetelés: Külső falazat: A homlokzati felületen található vakolati hibák javítása, majd síkra vakolása után Polisztirol lapokból álló hőszigetelő rendszer felragasztása a meglevő homlokzatra 12cm vastagságban (Baumit Grafit), dűbelezéssel, üvegszöveg háló beágyazásával, nemesvakolat felületképzéssel, a szükséges indító és sarokprofilok elhelyezésével. Belső födém: A belső határoló födémekre a meglévő 5cm fölé szálas szigetelés kerül ISOVER DOMO 15cm vastagságban. A szigetelés alá technológiai párazáró szigetelő fólia kell, hogy kerüljön az állagmegóvás érdekében. Nyílászárók cseréje: Az épület ablakai cserére szorulnak. Az ablakok esetében új fokozottan hőszigetelt fa profilú 3 rétegű üvegezéssel és melegperemes távtartóval szerelt szerkezet beépítése javasolt (U=min. 1,15 W/m2K). Az ajtók cseréje szintén korszerű anyagában fa nyílászárókra történik (U=min.1,15 w/m2K). Az ablakokra külső oldalról világos színű műanyag redőny felszerelésre történik, előre kialakított toktoldóra rögzítve. Fűtéskorszerűsítés, hőszivattyús rendszer kiépítése: Az épület hőtechnikai számításai alapján az épület helyiségeinek fűtési-hűtési igényei alacsony hőmérsékletű rendszerrel biztosítható. A telek adottságai és a projekt volumene alapján a legoptimálisabb megoldás hőtermelői oldalról levegő-víz hőszivattyú alkalmazása, melyhez fan-coil berendezések lettek betervezve alacsony hőmérsékletű közeghőmérsékletre méretezve. A kijelölt helységekbe DAIKIN FWF040BT típusú kazettás fan-coilok kerültek betervezésre. Az épület hűtési-fűtési energiaigényét központi gépészettel oldjuk meg. Világításkorszerűsítés: Az új alkalmazott világítási berendezések LED fényforrások, terv szerint Mainlux MXTP-01-40W 40W teljesítményű IP65 védett Ipari LED lámpatest 4000lm, megvilágítási méretezés szerint. Napelemes rendszer: Az épület bitumenes lemezzel borított tetejére 61 db, panel kerül elhelyezésre. 60 cellás, polikristályos modulok alu keretben, 3,2 mm vasmentes edzett szolárüveggel, EVA kitöltéssel, IP65-ös csatlakozó dobozzal, szolár vezetékkel, szolár csatlakozókkal. Névleges teljesítményük minimum 275 W, maximum 300 W lehet, hatásfokuk pedig legalább 15,9% kell legyen. Tervezett panel: CanadianSolar CS6k-280P 280W. Inverterek: Háromfázisú 400/3x230V, 50Hz hálózattal szinkron üzemben működő inverterek. 15 kVA csatlakozási összteljesítményű inverter: 1db FRONIUS SYMO 15.0-3-M. Napkollektoros rendszer: 8,4m2 felületű napkollektoros rendszer telepítése. Az épület tetejére új napkollektorok kerülnek, melyek elemei: 4db BOSCH FCC 220-2V Solar 4000 TF (4,2m2), niverzális bekötő készlet szerelőkeret, Összekötő elemkészlet acélcsöves szerelőkeretekhez , szoláris szerelési egység, 25 literes tágulási tartály, HC-1 szabályozó, Rugós biztonsági szelep 3/4”, 20 liter fagyálló hőátadó folyadék koncentrátum. A napkollektorok a kazánházban elhelyezett 500 literes kombinált HMV tárolóra dolgoznak rá. Az új HMV tároló a meglévő melegvíz rendszerre csatlakozik, átalakítás nélkül. (Hungarian)
    0 references
    The development covers the following sub-areas: External thermal insulation: Outer masonry: Repair the plastering defects on the facade surface and after plastering it onto the plane the thermal insulation system consisting of polystyrene sheets is attached to the existing façade in a thickness of 12 cm (Baumit Grafit), encapsulation of glass text netting, noble blinding, installation of the necessary starter and corner profiles. Interior slab: The inner boundary slabs are equipped with fibrous insulation above the existing 5 cm ISOVER DOMO 15 cm thickness. A technological vapor barrier insulating film must be placed under the insulation for the preservation of consistency. Replacement of doors and windows: The building’s windows need to be changed. In the case of windows, it is recommended to install a new structure with a high insulated wood profile with 3 layers of glazing and hot flange spacer (U=min. 1.15 W/m2K). The doors are also replaced with wooden doors in modern material (U=min.1,15 w/m2K). The windows are mounted from the outside to light-coloured plastic shutters, fixed to a pre-arranged detachment. Heating modernisation, installation of heat pump system: Based on the building’s thermal engineering calculations, the heating and cooling requirements of the building’s rooms can be ensured by a low-temperature system. Based on the conditions of the plot and the volume of the project, the most optimal solution from the heat producer side is the use of air-water heat pumps, for which fan-coil equipment has been designed for low-temperature medium temperature. DAIKIN FWF040BT cassette fan-coils have been designed in the designated areas. The cooling and heating energy demand of the building is solved by central engineering. Modernisation of lighting: The new applied lighting equipment is LED light sources, designed according to Mainlux MXTP-01-40 W 40 W IP65 Protected Industrial LED luminaire 4 000 lm, lighting sizing. Solar system: 61 panels are placed on the roof of the building covered with bituminous plates. 60 cell polycrystalline modules with aluminium frame, 3.2 mm iron-free hardened solar glass, EVA filling, IP65 connector box, solar wire, solar connectors. They shall have a rated power of at least 275 W, a maximum of 300 W and an efficiency of at least 15.9 %. Designed panel: CanadianSolar CS6k-280P 280 W. Inverters: Three-phase 400/3x230V inverters operating in synchronous operation with a 50 Hz network. 15 kVA total power inverter: 1pc FRONIUS SYMO 15.0-3-M. Solar collector system: Installation of an 8.4 m² solar collector system. New solar collectors are placed on the roof of the building, consisting of: 4pcs BOSCH FCC 220-2V Solar 4000 TF (4.2 m²), niversal insert set assembly frame, connecting battery set for steel tube mounting frames, solar assembly unit, 25 liter expansion tank, HC-1 regulator, spring safety valve 3/4", 20 liter antifreeze transfer fluid concentrate. Solar collectors work on the 500 litre combined HMV storage in the boiler room. The new HMV storage is connected to the existing hot water system, without conversion. (English)
    8 February 2022
    0 references
    Le développement couvre les sous-domaines suivants: Isolation thermique externe: Maçonnerie extérieure: Réparer les défauts de plâtrage sur la surface de la façade et après le plâtrage sur le plan le système d’isolation thermique constitué de feuilles de polystyrène est fixé à la façade existante dans une épaisseur de 12 cm (Baumit Grafit), encapsulation de filet de texte en verre, noble aveuglage, pose du démarreur et des profilés d’angle nécessaires. Dalle intérieure: Les dalles de bordure intérieure sont équipées d’une isolation fibreuse au-dessus de l’épaisseur existante ISOVER DOMO 15 cm. Une pellicule isolante de barrière de vapeur technologique doit être placée sous l’isolation pour préserver la consistance. Remplacement des portes et fenêtres: Les fenêtres du bâtiment doivent être changées. Dans le cas des fenêtres, il est recommandé d’installer une nouvelle structure avec un profilé en bois isolé élevé avec 3 couches de vitrage et un entretoise à bride chaude (U=min. 1,15 W/m2K). Les portes sont également remplacées par des portes en bois en matériau moderne (U=min.1,15 w/m2K). Les fenêtres sont montées de l’extérieur à des volets en plastique de couleur claire, fixés à un détachement pré-arrangé. Modernisation du chauffage, installation d’un système de pompe à chaleur: Sur la base des calculs thermiques du bâtiment, les exigences en matière de chauffage et de refroidissement des locaux du bâtiment peuvent être assurées par un système à basse température. Sur la base des conditions de la parcelle et du volume du projet, la solution la plus optimale du côté du producteur de chaleur est l’utilisation de pompes à chaleur air-eau, pour lesquelles l’équipement de ventilateur-coil a été conçu pour la température moyenne à basse température. Les ventilateurs à cassettes Daikin FWF040BT ont été conçus dans les zones désignées. La demande d’énergie de refroidissement et de chauffage du bâtiment est résolue par l’ingénierie centrale. Modernisation de l’éclairage: Le nouvel équipement d’éclairage appliqué est des sources de lumière LED, conçues selon Mainlux MXTP-01-40 W 40 W IP65 Protégé luminaire LED industriel 4 000 lm, dimensionnement d’éclairage. Système solaire: 61 panneaux sont placés sur le toit du bâtiment recouvert de plaques bitumineuses. 60 modules polycristallins à cellules avec cadre en aluminium, verre solaire trempé sans fer de 3,2 mm, remplissage EVA, boîtier de connecteur IP65, fil solaire, connecteurs solaires. Ils doivent avoir une puissance nominale d’au moins 275 W, un maximum de 300 W et un rendement d’au moins 15,9 %. Panneau conçu: CanadianSolar CS6k-280P 280 W. Onduleurs: Onduleurs triphasés 400/3x230V fonctionnant en fonctionnement synchrone avec un réseau de 50 Hz. Onduleur de puissance totale de 15 kVA: 1pc FRONIUS SYMO 15.0-3-M. Système de collecteur solaire: Installation d’un système de collecteur solaire de 8,4 m². De nouveaux capteurs solaires sont placés sur le toit du bâtiment, comprenant: 4pcs BOSCH FCC 220-2V Solar 4000 TF (4,2 m²), cadre d’assemblage d’inserts niversaux, batterie de raccordement pour cadres de montage de tubes en acier, unité d’assemblage solaire, réservoir d’expansion de 25 litres, régulateur HC-1, soupape de sécurité à ressort 3/4", concentré de fluide de transfert antigel de 20 litres. Les capteurs solaires travaillent sur le stockage combiné HMV de 500 litres dans la chaufferie. Le nouveau stockage HMV est connecté au système d’eau chaude existant, sans conversion. (French)
    10 February 2022
    0 references
    Balatonkeresztúr, Somogy
    0 references

    Identifiers

    GINOP-4.1.2-18-2018-00153
    0 references