Implementation of a statistical reconstructive algorithm for a CT scan diagnostic station characterised by a reduced dose of radiation absorbed by the patient during the study (Q78019)

From EU Knowledge Graph
Revision as of 08:14, 7 December 2021 by DG Regio (talk | contribs) (‎Changed label, description and/or aliases in de, and other parts: Adding German translations)
Jump to navigation Jump to search
Project Q78019 in Poland
Language Label Description Also known as
English
Implementation of a statistical reconstructive algorithm for a CT scan diagnostic station characterised by a reduced dose of radiation absorbed by the patient during the study
Project Q78019 in Poland

    Statements

    0 references
    457,232.04 zloty
    0 references
    109,735.69 Euro
    13 January 2020
    0 references
    601,662.0 zloty
    0 references
    144,398.88 Euro
    13 January 2020
    0 references
    75.99 percent
    0 references
    1 October 2017
    0 references
    30 September 2018
    0 references
    STATREK SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
    0 references
    0 references

    50°48'32.4"N, 19°7'27.8"E
    0 references
    Numer_referencyjny_programu_pomocowego: SA.41471(2015/X) Przeznaczenie_pomocy_publicznej: art. 25 rozporządzenia KE nr 651/2014 z dnia 17 czerwca 2014 r. uznające niektóre rodzaje pomocy za zgodne z rynkiem wewnętrznym w stosowaniu art. 107 i 108 Traktatu (Dz. Urz. UE L 187/1 z 26.06.2014). Celem tego projektu jest zbudowanie systemu komputerowego wykorzystującego opracowaną przez kierownika tego projektu nowatorską statystyczną iteracyjną metodę rekonstrukcji obrazu z projekcji. Działanie tego systemu informatycznego adresowane jest ściśle na potrzeby tomografii komputerowej CT. Chodzi tutaj w szczególności o udokumentowaną naukowo dużą szkodliwość promieniowania rentgenowskiego dla ludzkiego zdrowia. W związku z tym producenci tomografów komputerowych poszukują usilnie metod ograniczenia dawki promieniowania pochłanianej przez badanych tą techniką pacjentów, aby zapewnić zbyt produkowanym przez siebie aparatom CT. System opracowany w ramach tego projektu stanowić będzie wsparcie dla medycznego aparatu rentgenowskiego tomografii komputerowej, który w bardzo krótkim czasie pozwoli na otrzymywanie diagnostycznych obrazów tomograficznych. Rozwiązanie takie charakteryzować się będzie znacznym zmniejszeniem dawki promieniowania rentgenowskiego pochłoniętej przez pacjenta w trakcie badania. Przewagą tego systemu nad istniejącymi rozwiązaniami konkurencyjnymi jest własność proponowanego do implementacji w ramach tego projektu rozwiązania algorytmicznego w postaci nieporównywalnie mniejszej złożoności obliczeniowej, głównie dzięki możliwości zastosowania w nim algorytmów FFT. Ponadto, z matematycznego punktu widzenia, sposób sformułowania w tej metodzie problemu rekonstrukcyjnego zapewnia większą odporność algorytmu na szumy pomiarowe występujące w tomografii CT. W ramach projektu przeprowadzone zostaną prace nad praktycznymi metodami zrównoleglenia obliczeń wykonywanych przez algorytm rekonstrukcyjny z wykorzystaniem różnych podejść softwarowych i hardwarowych. (Polish)
    0 references
    Reference number of the aid programme: SA.41471(2015/X) Purpose of public aid: Article 25 of EC Regulation No 651/2014 of 17 June 2014 declaring certain types of aid compatible with the internal market in the application of Articles 107 and 108 of the Treaty (OJ L. I'm sorry. EU L 187/1 of 26.06.2014). The aim of this project is to build a computer system using an innovative statistical iterative method of reconstructing the projection image developed by the project manager. The operation of this IT system is addressed strictly for the purposes of CT computed tomography. This concerns in particular the scientifically documented high harmfulness of X-rays to human health. As a result, manufacturers of computer tomographs are looking for methods to reduce the dose of radiation absorbed by this technique in order to provide too-produced CT apparatus. The system developed within this project will provide support for the medical X-ray apparatus tomography, which in a very short time will allow for receiving diagnostic tomographic images. This solution will be characterised by a significant reduction in the dose of X-ray absorbed by the patient during the study. The advantage of this system over existing competitive solutions is the property of the proposed algorithm solution in the form of incomparably less computational complexity, mainly due to its ability to use FFT algorithms. In addition, from a mathematical point of view, the method of formulating the reconstructive problem in this method ensures greater resistance of the algorithm to measurement noises occurring in CT tomography. As part of the project, work will be carried out on practical methods of parallelisation of calculations performed by the reconstructive algorithm using various software and hardware approaches. (English)
    14 October 2020
    0 references
    Reference_Aid_programme: SA.41471(2015/X) But_public_aid: Article 25 du règlement (CE) no 651/2014 du 17 juin 2014 déclarant certaines catégories d’aides compatibles avec le marché intérieur en application des articles 107 et 108 du traité (JO URZ. EU L 187/1 du 26.6.2014). L’objectif de ce projet est de construire un système informatique à l’aide d’une méthode innovante et itérative statistique de reconstruction de l’image de projection développée par le chef de projet. Le fonctionnement de ce système informatique est strictement traité pour la tomodensitométrie CT. Cela concerne, en particulier, les dommages élevés des rayons X pour la santé humaine scientifiquement documentés. Par conséquent, les producteurs de CT recherchent des méthodes pour réduire la dose de rayonnement absorbée par cette technique afin de fournir un équipement de tomodensitométrie qu’ils produisent trop. Le système développé dans le cadre de ce projet soutiendra l’appareil de radiographie médicale de la tomodensitométrie, qui permettra en très peu de temps de recevoir des images de tomographie diagnostique. Cela se caractérisera par une réduction significative de la dose de rayons X absorbée par le patient au cours de l’étude. L’avantage de ce système par rapport aux solutions concurrentielles existantes est la propriété de la solution algorithmique proposée pour ce projet sous la forme d’une complexité incomparablement moins computationnelle, principalement en raison de sa capacité à utiliser les algorithmes FFT. En outre, d’un point de vue mathématique, la méthode de formulation du problème de reconstruction dans cette méthode assure une plus grande résistance de l’algorithme au bruit de mesure trouvé dans la tomographie CT. Dans le cadre du projet, des travaux seront menés sur des méthodes pratiques de parallélisation des calculs effectués par l’algorithme de reconstruction à l’aide de diverses approches logicielles et matérielles. (French)
    30 November 2021
    0 references
    Referenz_Aid_Programm: SA.41471(2015/X) Zweck_public_aid: Artikel 25 der Verordnung (EG) Nr. 651/2014 vom 17. Juni 2014 zur Feststellung der Vereinbarkeit bestimmter Gruppen von Beihilfen mit dem Binnenmarkt in Anwendung der Artikel 107 und 108 AEUV (ABl. URZ. EU L 187/1 vom 26.6.2014). Ziel dieses Projekts ist es, ein Computersystem mit der innovativen statistischen iterativen Methode zur Rekonstruktion des vom Projektmanager entwickelten Projektionsbildes zu bauen. Der Betrieb dieses IT-Systems ist streng auf die CT-Tomographie von CT ausgerichtet. Dies betrifft insbesondere den wissenschaftlich dokumentierten hohen Schaden von Röntgenstrahlen für die menschliche Gesundheit. Daher suchen CT-Hersteller nach Methoden, um die durch diese Technik absorbierte Strahlungsdosis zu reduzieren, um CT-Geräte bereitzustellen, die sie zu viel produzieren. Das im Rahmen dieses Projekts entwickelte System wird den medizinischen Röntgenapparat der Computertomographie unterstützen, der in kürzester Zeit diagnostische Tomographiebilder erhalten kann. Dies wird durch eine signifikante Verringerung der vom Patienten während der Studie aufgenommenen Röntgendosis gekennzeichnet sein. Der Vorteil dieses Systems gegenüber bestehenden Wettbewerbslösungen ist das Eigentum an der vorgeschlagenen algorithmischen Lösung für dieses Projekt in Form einer unvergleichlich geringeren Rechenkomplexität, vor allem aufgrund seiner Fähigkeit, FFT-Algorithmen zu verwenden. Darüber hinaus sorgt die Methode zur Formulierung des rekonstruktiven Problems in dieser Methode aus mathematischer Sicht für einen größeren Widerstand des Algorithmus gegen das Messgeräusch in der CT-Tomographie. Im Rahmen des Projekts werden praktische Methoden zur Parallelisierung von Berechnungen durch den rekonstruktiven Algorithmus mit unterschiedlichen Software- und Hardwareansätzen durchgeführt. (German)
    7 December 2021
    0 references

    Identifiers

    POIR.01.01.01-00-0463/17
    0 references