Objetivo: Optimización y estudio de utilidad de un compuesto químico patentado por nuestro grupo, cuyo uso como tinta marcadora radio-opaca supone una novedad en el campo de la biomedicina. Diseño: A partir de este compuesto ya desarrollado, en una primera fase se realizarán ensayos químicos de laboratorio para determinar su composición óptima, el aplicador más práctico y el protocolo de uso más eficaz sobre fantomas de simulación del cuerpo humano, para su validación como marcador en estudios radiográficos estándar. En una segunda fase, se realizará un estudio longitudinal prospectivo de pacientes (N= 200) con patología traumatológica en Urgencias y Quirófanos de Traumatología, para determinar su utilidad “in vivo”. Se exigirá consentimiento informado en todos los casos y autorización del Comité de Bioética. La asignación al grupo de estudio se hará de forma aleatoria. En el grupo “Casos” se aplicará de manera controlada la tinta radio-opaca para los estudios radiológicos e intervenciones quirúrgicas y se comparará con un grupo de “Controles” en los que será aplicada otra tinta no radio-opaca “placebo”. Se analizarán indicadores de mejoría en la eficacia del diagnóstico radiológico y en la técnica quirúrgica, de acortamiento en los tiempos quirúrgicos y de disminución de la exposición a radiación de pacientes y personal sanitario, con el uso del nuevo marcador. Instrumentos-determinaciones Se utilizarán instrumentos y criterios diagnósticos con fiabilidad documentada, y clasificaciones oficiales como AO/ASIF de fracturas o la Escala Visual Analógica del dolor . La eficacia diagnóstica será evaluada por un panel de expertos “ciegos” a la intervención. (Spanish)
0 references
Objective: Optimisation and study of usefulness of a chemical compound patented by our group, whose use as a radio-opaque marker ink is a novelty in the field of biomedicine. Design: From this compound already developed, in a first phase will be carried out laboratory chemical tests to determine its optimal composition, the most practical applicator and the most effective protocol of use on simulation fantoms of the human body, for validation as a marker in standard radiographic studies. In a second phase, a prospective longitudinal study of patients (N=200) with traumatic pathology in the ER and Traumatology Operators will be carried out to determine their usefulness “in vivo”. Informed consent shall be required in all cases and authorisation of the Bioethics Committee. Assignment to the study group shall be done at random. In the case group, radio-opaque ink shall be applied in a controlled manner for radiological studies and surgical interventions and compared with a group of “Controls” in which another non-radio-opaque “placebo” ink will be applied. Indicators of improvement in the effectiveness of radiological diagnosis and surgical technique, shortening in surgical times and reduction of radiation exposure of patients and healthcare personnel will be analysed, with the use of the new marker. Instruments-determinations Diagnostic instruments and criteria will be used with documented reliability, and official classifications such as AO/ASIF fractures or the Analog Visual Pain Scale. The diagnostic effectiveness will be evaluated by a panel of experts “blind” to the intervention. (English)
12 October 2021
0 references
Objectif: Optimisation et étude de l’utilité d’un composé chimique breveté par notre groupe, dont l’utilisation comme marqueur radio-opaque est une nouveauté dans le domaine de la biomédecine. Conception: À partir de ce composé déjà développé, dans une première phase seront réalisés des essais chimiques de laboratoire pour déterminer sa composition optimale, l’applicateur le plus pratique et le protocole d’utilisation le plus efficace sur les fantomes de simulation du corps humain, pour la validation comme marqueur dans les études radiographiques standard. Dans une deuxième phase, une étude longitudinale prospective de patients (N=200) présentant une pathologie traumatique dans les urgences et les opérateurs de Traumatologie sera réalisée afin de déterminer leur utilité «in vivo». Le consentement éclairé est requis dans tous les cas et l’autorisation du comité de bioéthique. L’affectation au groupe d’étude se fait au hasard. Dans le groupe de cas, l’encre radioopaque doit être appliquée de manière contrôlée pour les études radiologiques et les interventions chirurgicales et comparée à un groupe de «contrôles» dans lequel une autre encre «placebo» non radioopaque sera appliquée. Les indicateurs d’amélioration de l’efficacité du diagnostic radiologique et de la technique chirurgicale, de raccourcissement des temps de chirurgie et de réduction de l’exposition aux rayonnements des patients et du personnel de santé seront analysés, avec l’utilisation du nouveau marqueur. Les instruments et les critères de diagnostic seront utilisés avec une fiabilité documentée, et des classifications officielles telles que les fractures AO/ASIF ou l’échelle de douleur visuelle analogique. L’efficacité du diagnostic sera évaluée par un groupe d’experts «aveugle» à l’intervention. (French)