Thermomodernisation of administrative buildings of the Regional Road Administration – buildings of the Road Districts in Wolbrom and Sieradza (Q2708772)

From EU Knowledge Graph
Revision as of 10:35, 4 December 2021 by DG Regio (talk | contribs) (‎Changed label, description and/or aliases in fr, and other parts: Adding French translations)
Jump to navigation Jump to search
Project Q2708772 in Poland
Language Label Description Also known as
English
Thermomodernisation of administrative buildings of the Regional Road Administration – buildings of the Road Districts in Wolbrom and Sieradza
Project Q2708772 in Poland

    Statements

    0 references
    0 references
    0 references
    165,653.43 zloty
    0 references
    36,824.76 Euro
    0.2223 Euro
    0 references
    276,089.07 zloty
    0 references
    61,374.6 Euro
    0.2223 Euro
    0 references
    60.0 percent
    0 references
    14 September 2020
    0 references
    31 March 2021
    0 references
    WOJEWÓDZTWO MAŁOPOLSKIE
    0 references
    0 references

    50°23'5.3"N, 19°45'35.6"E
    0 references

    50°8'0.6"N, 20°53'9.2"E
    0 references
    Na podstawie przeprowadzonej analizy dla budynku Obwodu Drogowego w Wolbromiu został wybrany jako optymalny następujący wariant przedsięwzięcia:1. Docieplenie dachu płytami ze styropapy o grubości 18 cm i współczynniku przewodzenia ciepła materiału 0,040 W mK powierzchnia do docieplenia wynosi 228,1 m2.2. Wymiana i zamontowanie przy grzejnikach zaworów termostatycznych z automatyczną regulacją miejscową. 3. Przeprowadzenie płukania instalacji. 4. Wymiana źródła ciepła na kondensacyjny kocioł gazowy opalany gazem ziemnym. Zaplanowano kocioł gazowy kondensacyjny, jednofunkcyjny o mocy 21kWNa podstawie przeprowadzonej analizy dla budynku Obwodu Drogowego w Sieradzy został wybrany jako optymalny następujący wariant przedsięwzięcia:1. Docieplenie ścian zewnętrznych styropianem fasadowym o grubości 15 cm i współczynniku przewodzenia ciepła materiału 0,038 W mK z zastosowaniem technologii lekkiejmokrej. Powierzchnia ścian do docieplenia wynosi 453,68m2.2. Docieplenie stropodachu wentylowanego płytami z wełny mineralnej o grubości 25 cm i współczynniku przewodzenia ciepła materiału 0,042 W mK powierzchnia stropodachu do docieplenia wynosi 206,82m2.3. Wymiana okien na piętrze na okna z nawiewnikami, o współczynniku przewodzenia ciepła 1,1 W m2 K 21 sztuk okien o powierzchni 48,04m2.4. Wymiana i montaż przy grzejnikach zaworów termostatycznych z automatyczną regulacją miejscową.5. Przeprowadzenie płukania instalacji.6. Wymiana źródła ciepła na kondensacyjny kocioł gazowy opalany gazem ziemnym. Zaplanowano kocioł kondensacyjny, jednofunkcyjny o mocy 28kW.Po zamontowaniu w ww budynkach pieca gazowego, każdy z nich zostanie opomiarowany licznikiem gazu.cd w pkt Q (Polish)
    0 references
    On the basis of the analysis carried out for the Wolbrom Road Circuit Building, it was selected as the optimal option of the project:1. The insulation of the roof with 18 cm thick styropap plates and the thermal conduction coefficient of the material 0.040 W mK is 228.1 m².2. Replacement and installation of thermostatic valve heaters with automatic local control. 3. Carrying out rinsing of the installation. 4. Replacing the heat source with a condensing gas boiler fired with natural gas. A condensation gas boiler with a power of 21 kW was planned. Based on the analysis carried out for the Sieradza Road Circuit Building, it was selected as the optimal option of the project:1. Insulation of external walls with 15 cm thick polystyrene façade and thermal conductivity coefficient 0.038 W mK using light wet technology. The surface area of the walls for warming is 453,68 m².2. The warming of the vented floor with 25 cm thick mineral wool panels and the thermal conduction coefficient of the material 0.042 W mK shall be 206,82 m².3. Replacing windows on the floor with diffusers, with a heat conduction coefficient of 1.1 W m² K 21 pcs windows with an area of 48.04 m².4. Replacement and installation of thermostatic valve radiators with automatic local control.5. Rinsing of the system.6. Replacing the heat source with a condensing gas boiler fired with natural gas. A single-function boiler with a capacity of 28 kW is planned.After the installation of the gas furnace in the above buildings, each of them will be measured by a gas meter.cd in point Q (English)
    7 July 2021
    0 references
    Sur la base de l’analyse effectuée pour le bâtiment du circuit routier Wolbrom, il a été choisi comme l’option optimale du projet:1. L’isolation du toit avec 18 cm d’épaisseur styropap et le coefficient de conduction thermique du matériau 0,040 W mK est de 228,1 m².2. Remplacement et installation d’appareils de chauffage thermostatiques avec commande locale automatique. 3. Effectuer le rinçage de l’installation. 4. Remplacement de la source de chaleur par une chaudière à gaz de condensation alimentée au gaz naturel. Une chaudière à gaz à condensation d’une puissance de 21 kW a été prévue. Sur la base de l’analyse effectuée pour le bâtiment du circuit routier de Sieradza, elle a été sélectionnée comme l’option optimale du projet:1. Isolation des murs extérieurs avec façade en polystyrène de 15 cm d’épaisseur et coefficient de conductivité thermique 0,038 W mK en utilisant la technologie humide légère. La surface des murs pour le réchauffement est de 453,68 m².2. Le réchauffement du plancher ventilé avec des panneaux de laine minérale de 25 cm d’épaisseur et le coefficient de conduction thermique du matériau 0,042 W mK doivent être de 206,82 m².3. Remplacement des fenêtres au sol par des diffuseurs, avec un coefficient de conduction thermique de 1,1 W m² K 21 fenêtres pcs d’une superficie de 48,04 m².4. Remplacement et installation de radiateurs thermostatiques avec commande locale automatique.5. Rinçage du système.6. Remplacement de la source de chaleur par une chaudière à gaz de condensation alimentée au gaz naturel. Une chaudière à usage unique d’une capacité de 28 kW est prévue.Après l’installation du four à gaz dans les bâtiments ci-dessus, chacun d’eux sera mesuré par un compteur de gaz.cd au point Q (French)
    4 December 2021
    0 references

    Identifiers

    RPMP.04.03.02-12-0026/20
    0 references