LOW-COST ENGINE-FES HYBRID ORTHESIS FOR WALKING OF MEDULLAR INJURIES AND SIMULATION METHODS TO ASSIST DESIGN AND ADAPTATION (Q3156073)

From EU Knowledge Graph
Revision as of 08:11, 4 December 2021 by DG Regio (talk | contribs) (‎Changed label, description and/or aliases in fr, and other parts: Adding French translations)
Jump to navigation Jump to search
Project Q3156073 in Spain
Language Label Description Also known as
English
LOW-COST ENGINE-FES HYBRID ORTHESIS FOR WALKING OF MEDULLAR INJURIES AND SIMULATION METHODS TO ASSIST DESIGN AND ADAPTATION
Project Q3156073 in Spain

    Statements

    0 references
    53,530.4 Euro
    0 references
    66,913.0 Euro
    0 references
    80.0 percent
    0 references
    1 January 2016
    0 references
    31 December 2018
    0 references
    UNIVERSIDADE DA CORUÑA
    0 references
    0 references

    43°29'4.88"N, 8°13'59.38"W
    0 references
    15036
    0 references
    LOS SOLICITANTES LLEVAN MAS DE CINCO AÑOS TRABAJANDO EN EL DESARROLLO DE ORTESIS ACTIVAS DE RODILLA-TOBILLO-PIE DE BAJO COSTE PARA LA MARCHA DE LESIONADOS MEDULARES, HABIENDO LLEGADO A UN PROTOTIPO QUE UTILIZA UN MOTOR ELECTRICO PARA MOVER LA RODILLA DURANTE EL BALANCEO Y BLOQUEARLA DURANTE EL APOYO, CUYA ACTUACION SE CONTROLA EN FUNCION DEL GIRO DEL TOBILLO DEL PIE CONTRARIO (MEDIDO CON ENCODER) Y DEL ESTADO DE APOYO (MEDIDO CON SENSORES DE PRESION PLANTAR). EL SISTEMA ES PORTABLE MEDIANTE UNA MOCHILA QUE LLEVA EL USUARIO, EN LA QUE SE UBICAN UN PEQUEÑO ORDENADOR, LA TARJETA DE ADQUISICION, LOS DRIVERS DE LOS MOTORES Y LA BATERIA. UNA PACIENTE LESIONADA MEDULAR HA COLABORADO CON EL EQUIPO DURANTE TODO EL TIEMPO DE DESARROLLO Y, DESDE PRINCIPIOS DE ESTE AÑO, ESTA SIENDO SOMETIDA AL PROCESO DE ADAPTACION A LAS ORTESIS._x000D_ EL PROYECTO QUE SE SOLICITA PRETENDE AVANZAR EN EL DESARROLLO DE LAS ORTESIS ACTIVAS MENCIONADAS SEGUN LAS SIGUIENTES DIRECCIONES: 1) MEJORAR EL DISPOSITIVO EXISTENTE, AUMENTANDO SU ROBUSTEZ (MENOS SENSORES Y MAS FIABLES), PORTABILIDAD (REDUCCION DEL EQUIPAMIENTO NECESARIO), USABILIDAD (FACILITAR TRANSICIONES) Y EFICIENCIA (REDUCCION DEL CONSUMO ENERGETICO); 2) INTRODUCIR LA ELECTROESTIMULACION FUNCIONAL (FES) EN EL DISPOSITIVO, FUENTE DE MUCHOS BENEFICIOS PARA EL PACIENTE, CONTEMPLANDO SU INTEGRACION CON LA ACTUACION DEL MOTOR; 3) ESTUDIAR LA UTILIDAD PARA USUARIOS CON DISTINTOS NIVELES DE LESION, AMPLIANDO EL NUMERO DE PACIENTES, DE MANERA QUE SE PUEDA ESTABLECER UN PROTOCOLO PARA EL PROCESO DE ADAPTACION, TAN IMPORTANTE PARA EL EXITO DEL DISPOSITIVO COMO LAS PROPIAS CARACTERISTICAS TECNICAS DEL MISMO; 4) PROFUNDIZAR EN LA UTILIZACION DE METODOS DE SIMULACION DE APOYO AL DISEÑO Y LA ADAPTACION, ABORDANDO EL ANALISIS Y LA PREDICCION DE MOVIMIENTO MEDIANTE MODELOS NEURO-MUSCULO-ESQUELETICOS SUJETO-ORTESIS PERSONALIZADOS. (Spanish)
    0 references
    APPLICANTS HAVE BEEN WORKING FOR MORE THAN FIVE YEARS ON THE DEVELOPMENT OF LOW-COST KNEE-TONKLE-FOOT ACTIVE ORTHESIS FOR THE MARCH OF SPINAL INJURIES, HAVING REACHED A PROTOTYPE THAT USES AN ELECTRIC MOTOR TO MOVE THE KNEE DURING THE SWING AND BLOCK IT DURING THE SUPPORT, WHOSE PERFORMANCE IS CONTROLLED ACCORDING TO THE ROTATION OF THE ANKLE OF THE OPPOSITE FOOT (MEASURED WITH ENCODER) AND THE SUPPORT STATE (MEASURED WITH PLANTAR PRESSURE SENSORS). THE SYSTEM IS PORTABLE BY MEANS OF A BACKPACK CARRIED BY THE USER, IN WHICH A SMALL COMPUTER, THE ACQUISITION CARD, THE DRIVERS OF THE ENGINES AND THE BATTERY ARE LOCATED. A MEDULAR PATIENT INCLUDED WITH THE DURANT EQUIPMENT ALL THE TIME OF DEVELOPMENT AND, FROM PRINCIPES OF THIS YEAR, I am adhering to the process of adaptation to ORTESIS._x000D_ THE PROJECT THIS REQUESTS TO BE IN THE DEVELOPMENT OF ACTIVE ORTHERS MENCIONED WITH THE Following Directions: 1) IMPROVE THE EXISTING DEVICE, INCREASING ITS ROBUSTNESS (LESS SENSORS AND MORE RELIABLE), PORTABILITY (REDUCING THE NECESSARY EQUIPMENT), USABILITY (FACILITATE TRANSITIONS) AND EFFICIENCY (REDUCING ENERGY CONSUMPTION); 2) INTRODUCE FUNCTIONAL ELECTROSTIMULATION (FES) INTO THE DEVICE, SOURCE OF MANY BENEFITS FOR THE PATIENT, CONTEMPLATING ITS INTEGRATION WITH THE OPERATION OF THE MOTOR; 3) STUDY THE USEFULNESS FOR USERS WITH DIFFERENT LEVELS OF INJURY, EXPANDING THE NUMBER OF PATIENTS, SO THAT A PROTOCOL FOR THE ADAPTATION PROCESS CAN BE ESTABLISHED, AS IMPORTANT FOR THE SUCCESS OF THE DEVICE AS THE TECHNICAL CHARACTERISTICS OF THE DEVICE ITSELF; 4) DEEPENING THE USE OF SIMULATION METHODS TO SUPPORT DESIGN AND ADAPTATION, ADDRESSING THE ANALYSIS AND PREDICTION OF MOVEMENT THROUGH CUSTOMISED NEURO-MUSCULO-SKELETON-SUBJECT-ORTHESIS MODELS. (English)
    12 October 2021
    0 references
    LES CANDIDATS TRAVAILLENT DEPUIS PLUS DE CINQ ANS À LA MISE AU POINT D’UNE THÈSE ACTIVE À FAIBLE COÛT POUR LE GENOU-TONKLE-PIED POUR LA MARCHE DES LÉSIONS DE LA COLONNE VERTÉBRALE, AYANT ATTEINT UN PROTOTYPE QUI UTILISE UN MOTEUR ÉLECTRIQUE POUR DÉPLACER LE GENOU PENDANT L’OSCILLATION ET LE BLOQUER PENDANT LE SUPPORT, DONT LES PERFORMANCES SONT CONTRÔLÉES SELON LA ROTATION DE LA CHEVILLE DU PIED OPPOSÉ (MESURÉE AVEC CODEUR) ET DE L’ÉTAT DE SOUTIEN (MESURÉ AVEC DES CAPTEURS DE PRESSION PLANTAIRE). LE SYSTÈME EST PORTABLE AU MOYEN D’UN SAC À DOS TRANSPORTÉ PAR L’UTILISATEUR, DANS LEQUEL SE TROUVENT UN PETIT ORDINATEUR, LA CARTE D’ACHAT, LES CONDUCTEURS DES MOTEURS ET LA BATTERIE. Un PATIENT MÉDULAIRE INCLUS AVEC L’ÉQUIPEMENT DURANT TOUT LE TEMPS DE DÉVELOPPEMENT ET, À partir des principes de cette année, j’adhère au processus d’adaptation à l’ORTESIS._x000D_Le PROJET DE CE QUESTIONS D’ÊTRE DANS LE DÉVELOPPEMENT D’ORTESIS ACTIFS AVEC LES instructions suivantes: 1) AMÉLIORER L’APPAREIL EXISTANT, EN AUGMENTANT SA ROBUSTESSE (MOINS DE CAPTEURS ET PLUS FIABLE), LA PORTABILITÉ (RÉDUCTION DE L’ÉQUIPEMENT NÉCESSAIRE), LA FACILITÉ D’UTILISATION (TRANSITIONS FACILITÉES) ET L’EFFICACITÉ (RÉDUCTION DE LA CONSOMMATION D’ÉNERGIE); 2) INTRODUIRE L’ÉLECTROSTIMULATION FONCTIONNELLE (FES) DANS L’APPAREIL, SOURCE DE NOMBREUX AVANTAGES POUR LE PATIENT, EN ENVISAGEANT SON INTÉGRATION AVEC LE FONCTIONNEMENT DU MOTEUR; 3) ÉTUDIER L’UTILITÉ POUR LES UTILISATEURS AVEC DIFFÉRENTS NIVEAUX DE BLESSURE, EN AUGMENTANT LE NOMBRE DE PATIENTS, DE SORTE QU’UN PROTOCOLE POUR LE PROCESSUS D’ADAPTATION PUISSE ÊTRE ÉTABLI, AUSSI IMPORTANT POUR LE SUCCÈS DU DISPOSITIF QUE LES CARACTÉRISTIQUES TECHNIQUES DE L’APPAREIL LUI-MÊME; 4) APPROFONDIR L’UTILISATION DE MÉTHODES DE SIMULATION POUR SOUTENIR LA CONCEPTION ET L’ADAPTATION, EN ABORDANT L’ANALYSE ET LA PRÉDICTION DU MOUVEMENT AU MOYEN DE MODÈLES PERSONNALISÉS DE NEURO-MUSCULO-SQUELETTE-SUJET-OUTHÈSE. (French)
    4 December 2021
    0 references
    Ferrol
    0 references

    Identifiers

    DPI2015-65959-C3-1-R
    0 references