Construction of a geothermal-biomass heating plant in Sieradz with injection hole Sieradz GT-2 (Q2692706)

From EU Knowledge Graph
Revision as of 18:32, 3 December 2021 by DG Regio (talk | contribs) (‎Changed label, description and/or aliases in fr, and other parts: Adding French translations)
Jump to navigation Jump to search
Project Q2692706 in Poland
Language Label Description Also known as
English
Construction of a geothermal-biomass heating plant in Sieradz with injection hole Sieradz GT-2
Project Q2692706 in Poland

    Statements

    0 references
    31,616,401.08 zloty
    0 references
    7,028,325.96 Euro
    0.2223 Euro
    0 references
    60,330,001.8 zloty
    0 references
    13,411,359.4 Euro
    0.2223 Euro
    0 references
    52.41 percent
    0 references
    1 September 2020
    0 references
    30 June 2023
    0 references
    PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ SPÓŁKA Z OGRANICZONA ODPOWIEDZIALNOŚCIĄ
    0 references
    0 references
    0 references

    52°15'21.2"N, 18°16'4.4"E
    0 references
    Przedsięwzięcie będzie polegać na budowie ciepłowni geotermalno-biomasowej w Sieradzu o mocy 22 MWt wraz z odwierceniem otworu zatłaczającego SIERADZ GT-2. Otwór zostanie wykonany jako kierunkowy typu "J" o głębokości końcowej wynoszącej ok. 1898 m przy rzeczywistej pionowej głębokości końcowej wynoszącej ok. 1525 m +/- 10%. Ciepłownia geotermalna będzie się opierać na pracy dubletu geotermalnego, tj. dwóch otworów geotermalnych: zrealizowanego otworu eksploatacyjnego Sieradz GT-1 oraz projektowanego otworu zatłaczającego Sieradz GT-2. Woda geotermalna pozyskiwana z otworu eksploatacyjnego Sieradz GT-1 będzie wykorzystywana na dwa sposoby: • W pierwszej kolejności jako bezpośrednie źródło ciepła dla systemu ciepłowniczego (wstępne podgrzewanie wody sieciowej powrotnej) poprzez przekazanie ciepła w płytowych skręcanych wymiennikach ciepła; wymienniki ciepła umożliwią podgrzanie wody sieciowej do maksymalnie 52°C, przy jednoczesnym schłodzeniu wody geotermalnej do ok. 49-50°C (schłodzenie wody geotermalnej będzie zależne od temperatury wody sieciowej powrotnej i może wynosić od 0 do ok. 5 K); • W drugiej kolejności woda geotermalna będzie stanowiła dolne źródło ciepła dla pomp ciepła; zakłada się zastosowanie 2 absorpcyjnych bromolitowych pomp ciepła o mocy cieplnej ok. 10 MWt każda. (Polish)
    0 references
    The project will consist of the construction of a geothermal-biomassage heating plant in Sieradz with a capacity of 22 MWt, together with the drilling of the injection hole SIERADZ GT-2. The opening shall be made as directional type “J” with a final depth of approx. 1898 m at an actual vertical final depth of approx. 1525 m ± 10 %. The geothermal heat room will be based on the work of the geothermal double, i.e. two geothermal holes: the Sieradz GT-1 operating hole and the Sieradz GT-2 injection hole. Geothermal water obtained from the Sieradz GT-1 operating hole will be used in two ways: • As a direct heat source for district heating (pre-heating of mains water return) by transferring heat in plate-twisted heat exchangers; heat exchangers will allow to heat the mains water to a maximum of 52 °C, while cooling the geothermal water to approx. 49-50 °C (cooling of the geothermal water will depend on the return mains water temperature and can range from 0 to approx. 5 K); • In the second place, geothermal water will be the lower heat source for heat pumps; it is assumed to use 2 absorption bromolite heat pumps with a heat output of approx. 10 MWt each. (English)
    7 July 2021
    0 references
    Le projet consistera en la construction d’une centrale de chauffage géothermique-biomassage à Sieradz d’une capacité de 22 MWt, ainsi que le forage du trou d’injection Sieradz GT-2. L’ouverture doit être faite en tant que type directionnel «J» avec une profondeur finale d’environ. 1 898 m à une profondeur finale verticale réelle d’env. 1 525 m ± 10 %. La salle de chauffage géothermique sera basée sur le travail du double géothermique, c’est-à-dire deux trous géothermiques: le trou d’opération Sieradz GT-1 et le trou d’injection Sieradz GT-2. L’eau géothermique obtenue à partir du trou d’exploitation de Sieradz GT-1 sera utilisée de deux manières: • En tant que source de chaleur directe pour le chauffage urbain (préchauffage du retour de l’eau du réseau) par transfert de chaleur dans des échangeurs de chaleur à plaques; les échangeurs de chaleur permettront de chauffer l’eau du réseau à un maximum de 52 °C, tout en refroidissant l’eau géothermique à environ. 49-50 °C (le refroidissement de l’eau géothermique dépendra de la température de l’eau du réseau de retour et peut varier de 0 à environ. 5 K); • En deuxième lieu, l’eau géothermique sera la source de chaleur inférieure pour les pompes à chaleur; il est supposé utiliser 2 pompes à chaleur à absorption bromolite d’une puissance calorifique d’env. 10 MWt chacun. (French)
    3 December 2021
    0 references

    Identifiers

    POIS.01.01.01-00-0004/19
    0 references