Energy modernisation of the facility of the Primary School in Good Street. Level 5, Municipality of Good (Q137632)

From EU Knowledge Graph
Revision as of 21:30, 2 December 2021 by DG Regio (talk | contribs) (‎Created claim: summary (P836): Le sujet de l’étude est d’effectuer des travaux de thermomodernisation au bâtiment public SP à Dobroj, ul. Proximal 5, commune du bien, à savoir: 1) réchauffement du roseau — toit en polystyrène et plancher d’une épaisseur de 20 cm. Le réchauffement de l’Attique avec le travail d’accompagnement a également été pris en compte. Zone de réchauffement — 628,60 m² 2) isolation des murs extérieurs (sud-ouest, sud-est, nord-ouest, nord-est, sud-est, su...)
Jump to navigation Jump to search
Project Q137632 in Poland
Language Label Description Also known as
English
Energy modernisation of the facility of the Primary School in Good Street. Level 5, Municipality of Good
Project Q137632 in Poland

    Statements

    0 references
    274,661.99 zloty
    0 references
    65,918.88 Euro
    13 January 2020
    0 references
    323,131.78 zloty
    0 references
    77,551.63 Euro
    13 January 2020
    0 references
    85.0 percent
    0 references
    20 July 2016
    0 references
    13 November 2017
    0 references
    GMINA DOBRA
    0 references
    0 references
    Przedmiotem opracowania jest dokonanie prac termomodernizacyjnych przy budynku Publicznej SP w Dobrej przy ul. Poziomkowej 5,Gmina Dobra, a mianowicie: 1) docieplenie stropodachu – styropianem dach i podłoga o grubości 20 cm. Uwzględniono także docieplenie attyki wraz z pracami towarzyszącymi. Powierzchnia docieplenia – 628,60 m2 2) docieplenie ścian zewnętrznych (południowy -zachód, południowy -wschód, północny-zachód, północny wschód, południowy -wschód) – np. termoorganika – fasada – Platinum plus (lub równoważne) o grubości 18 cm 3) wymiana stolarki okiennej na nową (okno przy hydroforni i kotłowni), na nowe EI 60, powierzchnia wymiany stolarki – 4,20 m2 4) wymiana stolarki drzwiowej na nową (drzwi hydroforni), na nowe EI 60, powierzchnia wymiany – 3,60 m2 Dany obiekt został wybudowany w 1964 r. i do dziś funkcjonuje jako budynek szkolny. Budynek posiada konstrukcję tradycyjną murowaną, nieizolowaną termicznie,jednokondygnacyjną, o kubaturze 1775,32 m3 i powierzchni netto– 592,20 m2. Z obiektu korzysta 277 osób. Okna zostały już wymienione na nowe–pozostało do wymiany okno i drzwi w hydroforni oraz przy kotłowni, ściany fundamentowe betonowe, ściany wewnętrzne murowane, natomiast podłoga na gruncie ma tradycyjny układ warstw z lat 70 ubiegłego wieku. Roczne zapotrzebowanie na ciepło do ogrzewania budynku (bez uwzględnienia sprawności systemu grzewczego i przerw w ogrzewaniu) – 596,29 GJ/rok . Dzięki przeprowadzonym pracom modernizacyjnym oszczędność zapotrzebowania ciepłą wyniesie 61,29 %, czyli powyżej 25% Inwestycja jest etapem szerszego przedsięwzięcia związanego z rozbudową szkoły w Dobrej. Efektem realizacji będzie bowiem wdrożenie działań związanych z głęboką, kompleksową modernizacją energetyczną obiektu oświatowego, który służy dzisiaj zarówno dzieciom jak i nauczycielom pracującym w obiekcie. (Polish)
    0 references
    The subject of the study is to carry out thermal modernisation works at the Public SP building in Dobry Street. Level 5, commune of Good, namely: 1) warming of the ceiling – Styrofoam roof and floor with a thickness of 20 cm. Warming of attic and accompanying work is also included. Warming area – 628.60 m² 2) warming of external walls (south -west, south-east, north-west, northeast, south-east) – e.g. thermoorganics – facade – Platinum plus (or equivalent) with a thickness of 18 cm 3) replacement of the window joinery with a new (window by hydroforne and boiler room), for the new EI 60, the area of the new woodwork – 4.20 m² 4. The building has a traditional brick structure, not thermally insulated, one storey, with a volume of 1775.32 m³ and a net area of 592,20 m². The facility is used by 277 people. The windows have already been replaced with new windows and doors in the hydroforne and boiler room, concrete foundation walls, brick interior walls, while the floor on the ground has traditional layers from the 70s of the last century. Annual heat demand for building heating (without taking into account the efficiency of the heating system and breaks in heating) – 596,29 GJ/year. Thanks to the modernisation work carried out, the warm demand savings will be 61.29 %, i.e. over 25 % The investment is a stage of a wider project related to the expansion of the school in Good. The result of the implementation will be the implementation of activities related to deep, comprehensive energy modernisation of the educational facility, which today serves both children and teachers working in the facility. (English)
    21 October 2020
    0 references
    Le sujet de l’étude est d’effectuer des travaux de thermomodernisation au bâtiment public SP à Dobroj, ul. Proximal 5, commune du bien, à savoir: 1) réchauffement du roseau — toit en polystyrène et plancher d’une épaisseur de 20 cm. Le réchauffement de l’Attique avec le travail d’accompagnement a également été pris en compte. Zone de réchauffement — 628,60 m² 2) isolation des murs extérieurs (sud-ouest, sud-est, nord-ouest, nord-est, sud-est, sud-est) — par exemple thermoorganique — façade — Platinum plus (ou équivalent) 18 cm d’épaisseur 3) remplacement de la menuiserie de fenêtre par une nouvelle (fenêtre à hydrophore et chaufferie), pour la nouvelle EI 60, la zone de remplacement de la menuiserie — 4,20 m² 4) le remplacement de la menuiserie de porte par une nouvelle (porte hydrophore), la nouvelle EI 60, la surface de remplacement — 3,60 m² Dana le bâtiment a été construit en 1964 et fonctionne encore comme un bâtiment scolaire. Le bâtiment a une structure traditionnelle en brique, non isolée thermique, d’un étage, d’un volume de 1 775,32 m³ et d’une superficie nette de 592,20 m². La propriété est utilisée par 277 personnes. Les fenêtres ont déjà été remplacées par une nouvelle fenêtre et des portes dans l’hydroforesterie et à la chaufferie, des murs de fondation en béton, des murs en briques internes, tandis que le sol au sol a une disposition traditionnelle de couches des années 70 du siècle dernier. Demande annuelle de chaleur pour le chauffage du bâtiment (sans tenir compte de l’efficacité du système de chauffage et des interruptions de chauffage) — 596.29 GJ/an. Grâce aux travaux de modernisation, les économies de chaleur seront de 61,29 %, soit plus de 25 %. L’investissement est une étape d’un projet plus large lié à l’expansion de l’école en Bon. Le résultat de la mise en œuvre sera la mise en œuvre de mesures liées à une modernisation énergétique approfondie et complète de l’établissement d’enseignement, qui dessert aujourd’hui à la fois les enfants et les enseignants qui y travaillent. (French)
    2 December 2021
    0 references

    Identifiers

    RPZP.02.06.00-32-A004/16
    0 references