THERMAL MODERNISATION OF THE SCHOOL BUILDING AT UL. GREY SERIALS 6 IN SUCHEDNIOW (Q127625)

From EU Knowledge Graph
Revision as of 11:16, 2 December 2021 by DG Regio (talk | contribs) (‎Created claim: summary (P836): Conformément aux audits de l’énergie et de l’efficacité énergétique, les travaux prévus comprennent la modernisation des cloisons: Plafond extérieur — épaisseur requise de la couche d’isolation thermique: 24 cm — DACH, Mur extérieur — épaisseur requise de la couche d’isolation thermique: 16 cm — FASADA, Hall extérieur — épaisseur requise. Couche isolante thermique: 9 cm — FASADA, Plafond extérieur — épaisseur requise de la couche d’isolation the...)
Jump to navigation Jump to search
Project Q127625 in Poland
Language Label Description Also known as
English
THERMAL MODERNISATION OF THE SCHOOL BUILDING AT UL. GREY SERIALS 6 IN SUCHEDNIOW
Project Q127625 in Poland

    Statements

    0 references
    1,492,022.31 zloty
    0 references
    358,085.35 Euro
    13 January 2020
    0 references
    1,755,320.37 zloty
    0 references
    421,276.89 Euro
    13 January 2020
    0 references
    85.0 percent
    0 references
    5 October 2016
    0 references
    30 September 2020
    0 references
    GMINA SUCHEDNIÓW
    0 references
    Zgodnie z Audytami energetycznym i efektywności energetycznej planowany zakres prac obejmuje modernizację przegród: Strop zewnętrzny – wymagana grubość warstwy izolacji termicznej: 24 cm – DACH, Ściana zewnętrzna – wymagana grubość warstwy izolacji termicznej: 16 cm – FASADA, Ściana zewnętrza sala – wymagana grubość . warstwy izolacji termicznej: 9 cm – FASADA, Strop zewnętrzny sala – wymagana grubość warstwy izolacji termicznej: 13 cm – DACH oraz modernizację grupy przegród :Okna 2,3” ‘Wentylacja grawitacyjna’ – wymagany współczynnik U dla nowej stolarki: 0,900 W/(m2xK), Okna 1,8” ‘Wentylacja grawitacyjna’ - wymagany współczynnik U dla nowej stolarki: 0,900 W/(m2xK), „Drzwi” ‘Wentylacja grawitacyjna’ - wymagany współczynnik U dla nowej stolarki: 1,300 W/(m2xK). Prace obejmują także modernizację instalacji grzewczej – wymiana wew. sieci c.o., wymianę grzejników, montaż zaworów termostatycznych, uruchomienie systemu regulacji pogodowej, - wymianę opraw oświetleniowych wewnętrznych żarowych i świetlówkowych na oprawy LED, - montaż paneli PV (fotowoltaika) w celu produkcji energii elektrycznej na potrzeby własne, instalacja o wielkości 39 kW. Projekt jest zgodny z celami szczegółowymi dla osi priorytetowej 3 oraz celem działania 3.3 - Zwiększona efektywność energetyczna budynków publicznych oraz sektora mieszkaniowego. Wskaźniki osiągnięte w wyniku realizacji projektu - produktu: Szacowany roczny spadek emisji gazów cieplarnianych 322,56 tony równoważnika CO2/rok, Liczba wybudowanych jednostek wytwarzania energii elektrycznej z OZE 1 szt., Liczba zmodernizowanych energetycznie budynków 1 szt., Powierzchnia użytkowa budynków poddanych termomodernizacji 2184,40 m2, Zmniejszenie rocznego zużycia energii pierwotnej w budynkach publicznych 1042751 kWh/rok oraz rezultatu: Ilość zaoszczędzonej energii elektrycznej 20,65 MWh/rok, Ilość zaoszczędzonej energii cieplnej 2916,44 GJ/rok, Zmniejszenie zużycia energii końcowej w wyniku realizacji projektów 2991,76 GJ/rok (Polish)
    0 references
    According to energy audits and energy efficiency, the planned scope of work includes the modernisation of partitions: Outer ceiling – required thickness of the thermal insulation layer: 24 cm – DACH, Outside wall – required thermal insulation layer thickness: 16 cm – facade, outer wall hall – required thickness. thermal insulation layer: 9 cm – facade, outer ceiling hall – required thickness of thermal insulation layer: 13 cm – DACH and modernisation of the group of partitions:Windows 2,3" ‘Gravitational centrifuge’ – required U coefficient for the new joinery: 0,900 W/(m2xK), Windows 1,8" ‘Gravitational centrifuge’ – U coefficient required for the new joinery: 0,900 W/(m2xK), “Door” ‘Gravitational centrifuge’ – the required U coefficient for the new woodworking: 1,300 W/(m2xK). The works also include modernisation of the heating system – replacement of the heating network, replacement of radiators, installation of thermostatic valves, commissioning of the weather control system, – replacement of internal incandescent and fluorescent luminaires with LED luminaires, – installation of PV panels (photovoltaics) to produce electricity for own use, installation of 39 kW. The project is in line with the specific objectives for priority axis 3 and the objective of Action 3.3 – Increased energy efficiency of public buildings and the housing sector. Indicators achieved as a result of the project – product: Estimated annual decrease in greenhouse gas emissions of 322.56 tonnes CO2/year, Number of built electricity generation units from RES 1 units, Number of energy upgraded buildings 1 units, Use area of buildings undergoing thermal modernisation 2184.40 m², Reduction of annual primary energy consumption in public buildings 1042751 kWh/year and the result: Amount of electricity saved 20,65 MWh/year, The amount of thermal energy saved 2916.44 GJ/year, Reduction of final energy consumption as a result of projects 2991,76 GJ/year (English)
    21 October 2020
    0 references
    Conformément aux audits de l’énergie et de l’efficacité énergétique, les travaux prévus comprennent la modernisation des cloisons: Plafond extérieur — épaisseur requise de la couche d’isolation thermique: 24 cm — DACH, Mur extérieur — épaisseur requise de la couche d’isolation thermique: 16 cm — FASADA, Hall extérieur — épaisseur requise. Couche isolante thermique: 9 cm — FASADA, Plafond extérieur — épaisseur requise de la couche d’isolation thermique: 13 cm — DACH et modernisation de przegród:Okna 2,3" ‘aération de masse’ — Facteur U requis pour une nouvelle menuiserie: 0,900 W/(m2xK), fenêtre 1,8" ‘aération de masse’ — Facteur U requis pour une nouvelle menuiserie: 0,900 W/(m2xK), ‘portes’ ‘aération de masse’ — Facteur U requis pour une nouvelle menuiserie: 1300 W/(m2xK). Les travaux comprennent également la modernisation du système de chauffage — remplacement des réseaux de chauffage interne, remplacement des radiateurs, installation de vannes thermostatiques, démarrage du système de contrôle des intempéries, — remplacement des luminaires à incandescence et fluorescents pour luminaires LED, — installation de panneaux photovoltaïques (photovoltaics) pour la production d’électricité pour usage propre, installation de 39 kW. Le projet est conforme aux objectifs spécifiques de l’axe prioritaire 3 et de l’action 3.3 — Amélioration de l’efficacité énergétique des bâtiments publics et du secteur du logement. Indicateurs obtenus grâce au projet — extrants: Diminution annuelle estimée des émissions de gaz à effet de serre 322,56 tonnes d’équivalent CO2/an, Nombre d’unités générées par SER construites 1 pcs., Nombre de bâtiments modernisés 1 pcs., Surface habitable des bâtiments faisant l’objet d’une rénovation thermique de 2 184,40 m², Réduction de la consommation annuelle d’énergie primaire dans les bâtiments publics 1 042 751 kWh/an et résultat: Quantité d’électricité économisée 20,65 MWh/an, quantité d’énergie thermique économisée 2916,44 GJ/an, Réduction de la consommation finale d’énergie à la suite des projets 2991,76 GJ/an (French)
    2 December 2021
    0 references

    Identifiers

    RPSW.03.03.00-26-0010/16