Modification of the internal stabilisation system for spine modelling during growth period (Q83917)
Jump to navigation
Jump to search
Project Q83917 in Poland
Language | Label | Description | Also known as |
---|---|---|---|
English | Modification of the internal stabilisation system for spine modelling during growth period |
Project Q83917 in Poland |
Statements
2,155,707.46 zloty
0 references
2,300,963.25 zloty
0 references
93.69 percent
0 references
1 December 2019
0 references
31 May 2021
0 references
NOVASPINE SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
0 references
Numer_referencyjny_programu_pomocowego: SA.41471(2015/X) Przeznaczenie_pomocy_publicznej: art: 25 rozporządzenia KE nr 651/2014 z dnia 17 czerwca 2014 r. uznające niektóre rodzaje pomocy za zgodne z rynkiem wewnętrznym w stosowaniu art. 107 i 108 Traktatu (Dz. Urz. UE L 187/1 z 26.06.2014). Celem projektu jest opracowanie technologii modyfikacji wewnętrznego stabilizatora kręgosłupa do leczenia skolioz u dzieci poprzez zwiększenie jego odporności na ścieranie, a tym samym zmniejszenie ryzyka degradacji tkankowej oraz zaburzeń w kinematyce kolumny kręgosłupa. Problem leczenia skolioz u dzieci nie został do dziś rozwiązany w sposób satysfakcjonujący. Opiera się on bowiem na dwóch wykluczających się założeniach: konieczności usztywnieniem stabilizowanego odcinka kręgosłupa oraz jednoczesnego umożliwienia niezahamowanego wzrostu. Obecnie stosowana jest tzw. etapowa metoda leczenia skolioz polegająca na rozsuwaniu stabilizatora metodami operacyjnymi. Konieczne jest opracowanie takiego rozwiązania, które pozwalałoby na jak najwcześniejszą korekcję skoliozy z jednoczesnym zmniejszeniem liczby operacji oraz ryzyka wystąpienia powikłań. Oferowane przez Novaspine Sp. z o.o. stabilizatory częściowo rozwiązują powyższy problem. Posiadają w swojej konstrukcji pary kinetyczne umożliwiające względne przemieszczenia elementów konstrukcyjnych stabilizatora bez konieczności ingerencji chirurgicznej. Rozwiązanie posiada jednak wady uniemożliwiające ich dalsze stosowanie. Występowanie tarcia pomiędzy rozsuwającymi się elementami stabilizatora powodujące degradację jego elementów i odkładanie cząstek stopów metalu w tkankach. To z kolei może być przyczyną występowania stanów zapalnych i skutków ubocznych. W wyniku realizacji projektu opracowane zostanie rozwiązanie umożlwiające wyeliminowanie występowania zużycia ciernego poprzez naniesienie powłoki DLC (Diamond Like Carbon) metodą PVD. Powłoki DLC charakteryzują się wysoką twardością i odpornością na ścieranie, a jednocześnie wykazu (Polish)
0 references
Reference number of the aid programme: SA.41471(2015/X) Purpose of public aid: Article: 25 EC Regulation No 651/2014 of 17 June 2014 declaring certain types of aid compatible with the internal market in the application of Articles 107 and 108 of the Treaty (OJ L. I'm sorry. EU L 187/1 of 26.06.2014). The aim of the project is to develop the technology of modifying the internal spine stabiliser for the treatment of scoliosis in children by increasing its resistance to abrasion, thereby reducing the risk of tissue degradation and disturbances in column kinematics of the spine. The problem of scoliosis treatment in children has not yet been solved satisfactorily. It is based on two excluded assumptions: the need to stiffen the stabilised spine and at the same time allow unrestrained growth. Currently, the so-called stage treatment of scoliosis is used, which consists of spreading the stabiliser using operating methods. It is necessary to develop a solution that would allow for the earliest possible correction of scoliosis, while reducing the number of operations and the risk of complications. The stabilisers offered by Novaspine Sp. z o.o. partially solve the above problem. They have kinetic pairs in their design allowing relative displacement of the structural elements of the stabiliser without the need for surgical interference. The solution, however, has defects that prevent them from being used. The occurrence of friction between the dispersing elements of the stabiliser causing degradation of its components and depositing of metal alloy particles in the tissues. This, in turn, can cause inflammation and side effects. As a result of the project, a solution will be developed to eliminate friction consumption by applying a DLC (Diamond Like Carbon) coating using the PVD method. DLC coatings are characterised by high hardness and resistance to abrasion, and at the same time a list (English)
14 October 2020
0 references
Reference_Aid_programme: SA.41471(2015/X) But_public_aid: Article: 25 du règlement (UE) no 651/2014 de la Commission du 17 juin 2014 déclarant certaines catégories d’aides compatibles avec le marché intérieur en application des articles 107 et 108 du traité URZ. EU L 187/1 du 26.6.2014). L’objectif du projet est de développer la technologie de modification du stabilisateur interne de la colonne vertébrale pour le traitement de la scoliose chez les enfants en augmentant sa résistance à l’abrasion, réduisant ainsi le risque de dégradation tissulaire et de troubles de la cinématique de la colonne vertébrale. Le problème du traitement de la scoliose chez les enfants n’a pas été résolu de manière satisfaisante à ce jour. Elle repose sur deux hypothèses mutuellement exclusives: la nécessité de raidir la colonne vertébrale stabilisée tout en permettant une croissance in stoppable. Actuellement, la méthode dite de traitement par étapes de la scoliose est utilisée, consistant à disperser le stabilisateur à l’aide de méthodes chirurgicales. Il est nécessaire de développer une solution qui permet la correction précoce de la scoliose tout en réduisant le nombre d’opérations et le risque de complications. Les stabilisateurs proposés par Novaspine Sp. z o.o. résolvent partiellement le problème ci-dessus. Ils ont des paires cinétiques dans leur conception qui permettent un déplacement relatif des éléments structuraux du stabilisateur sans nécessité d’intervention chirurgicale. Toutefois, la solution présente des inconvénients empêchant leur utilisation continue. L’apparition d’un frottement entre les éléments mobiles du stabilisateur causant une dégradation de ses composants et le dépôt de particules d’alliages métalliques dans les tissus. Ceci, à son tour, peut être la cause de l’inflammation et des effets secondaires. À la suite du projet, une solution sera mise au point pour éliminer l’usure du frottement en appliquant le revêtement DLC (Diamond Like Carbon) à l’aide de la méthode PVD. Les revêtements DLC sont caractérisés par une dureté élevée et une résistance à l’abrasion, et en même temps liste (French)
30 November 2021
0 references
Identifiers
POIR.04.01.01-00-0020/19
0 references