ENERGY IMPROVEMENT OF HOUSING IN C/S (Q3259567)
Jump to navigation
Jump to search
Project Q3259567 in Spain
Language | Label | Description | Also known as |
---|---|---|---|
English | ENERGY IMPROVEMENT OF HOUSING IN C/S |
Project Q3259567 in Spain |
Statements
26,419,967.2 Euro
0 references
33,024,959.0 Euro
0 references
80.0 percent
0 references
1 June 2018
0 references
31 December 2020
0 references
JUNTA DE ANDALUCIA
0 references
11028
0 references
CON CARGO A LA OPERACIÓN SE REALIZARÁN ACTUACIONES DE REHABILITACIÓN ENERGÉTICA EN 1 EDIFICIO DE VIVIENDAS DE TIPOLOGÍA PLURIFAMILIAR CON 2 ALTURAS SOBRE RASANTE EN LA CALLE SAGASTA 89, PUERTO REAL (CÁDIZ). EL USO DEL EDIFICIO ES PREDOMINANTEMENTE RESIDENCIAL, EXISTIENDO GARAJES Y 1 LOCAL COMERCIAL EN PLANTA BAJA. SE INTERVENDRÁ EN LA FACHADA, IMPLANTANDO UN SISTEMA DE AISLAMIENTO TÉRMICO POR LE EXTERIOR (SATE) QUE PALIARÁ LA FALTA DE AISLAMIENTO Y ADEMÁS RENOVARÁ LA IMAGEN EXTERIOR DE LOS EDIFICIOS. EN CUBIERTA SE IMPLEMENTARÁ UNA CUBIERTA INCLINADA VENTILADA CON AISLAMIENTO TÉRMICO. EN HUECOS DE FACHADA SE SUSTITUIRÁ EL VIEJO CONJUNTO DE CARPINTERÍA, VIDRIO Y PERSIANA POR UNO NUEVO CON ROTURA DE PUENTE TÉRMICO, VIDRIO BAJO EMISIVO DE 6MM + 15MM DE AIRE + 4 MM CON EQUIPO DE PERSIANA ESTANCA, AISLADO Y CON AIREADORES INTEGRADOS EN LA PERFILERÍA. LAS CARPINTERÍAS SERÁN DE MADERA RESPETANDO ASÍ EL GRADO DE PROTECCIÓN DE LA EDIFICACIÓN. SE ESTUDIARÁ LA POSIBILIDAD DE INSTALAR EQUIPOS DE GENERACIÓN Y ACUMULACIÓN COMUNITARIA DE CALOR PARA AGUA CALIENTE SANITARIA (ACS) O EQUIPOS DE AEROTERMIA COMPATIBLES CON EL GRADO DE PROTECCIÓN DE LA EDIFICACIÓN. SE INSTALARÁN EQUIPOS DE MONITORIZACIÓN DE CONSUMOS ENERGÉTICOS, CONDICIONES DE CONFORT Y CALIDAD DEL AIRE CON EL OBJETIVO DE CONOCER EL EFECTIVO CUMPLIMIENTO DE LOS OBJETIVOS PROPUESTOS Y FACILITAR INFORMACIÓN SOBRE EL COMPORTAMIENTO Y HÁBITOS DE LOS USUARIOS DE LAS VIVIENDAS. (Spanish)
0 references
UNDER THE OPERATION, ENERGY REHABILITATION ACTIONS WILL BE CARRIED OUT IN 1 MULTI-FAMILY TYPE HOUSING BUILDING WITH 2 HEIGHTS ABOVE GROUND IN CALLE SAGASTA 89, PUERTO REAL (CADIZ). THE USE OF THE BUILDING IS PREDOMINANTLY RESIDENTIAL, THERE ARE GARAGES AND 1 COMMERCIAL PREMISES ON THE GROUND FLOOR. IT WILL INTERVENE IN THE FAÇADE, IMPLANTING A THERMAL INSULATION SYSTEM BY THE EXTERIOR (SATE) THAT WILL ALLEVIATE THE LACK OF INSULATION AND ALSO RENEW THE EXTERIOR IMAGE OF THE BUILDINGS. ON DECK A VENTILATED INCLINED ROOF WITH THERMAL INSULATION SHALL BE IMPLEMENTED. IN FAÇADE GAPS THE OLD ASSEMBLY OF CARPENTRY, GLASS AND SHUTTER WILL BE REPLACED BY A NEW ONE WITH THERMAL BRIDGE BREAK, LOW EMISSIVE GLASS OF 6MM + 15MM OF AIR + 4 MM WITH EQUIPMENT OF WATERTIGHT SHUTTER, INSULATED AND WITH AERATORS INTEGRATED IN THE PROFILE. THE CARPENTERS WILL BE MADE OF WOOD THUS RESPECTING THE DEGREE OF PROTECTION OF THE BUILDING. THE POSSIBILITY OF INSTALLING COMMUNITY HEAT GENERATION AND ACCUMULATION EQUIPMENT FOR DOMESTIC HOT WATER (ACS) OR AEROTHERMAL EQUIPMENT COMPATIBLE WITH THE DEGREE OF PROTECTION OF THE BUILDING WILL BE CONSIDERED. EQUIPMENT WILL BE INSTALLED TO MONITOR ENERGY CONSUMPTION, COMFORT CONDITIONS AND AIR QUALITY IN ORDER TO KNOW THE EFFECTIVE FULFILMENT OF THE PROPOSED OBJECTIVES AND PROVIDE INFORMATION ON THE BEHAVIOUR AND HABITS OF THE USERS OF THE HOMES. (English)
14 October 2021
0 references
Puerto Real
0 references
Identifiers
A1431014F00014
0 references