498,273.31 Euro
0 references
586,203.89 Euro
0 references
0.85 percent
0 references
1 September 2017
0 references
1 November 2018
0 references
ilinský samosprávny kraj
0 references
Predkladaný projekt je zameraný na zvýenie EHB Spojenej koly ilina, a riei nedostatky v tepelnotechnickej, energetickej a hygienickej oblasti. V rámci realizácie pôjde o 2 budovy (kolská jedáleň, budova koly), kde na základe spracovaného EA vylo najavo, e objekty vykazujú nedostatočné tepelno-izolačné vlastnosti, zlý stav svietidiel a rozvodov ÚK a TV, s negatívnym dopadom na zvýenú energetickú a finančnú náročnos. Projektom sa zrealizuje výmena výplní otvorov, zateplenie obvodových a strených pláov, sekundárne rozvody ÚK a TV s cirkuláciou, vykurovanie MaR (nové rozvody vykurovania a vykurovacích telies v budovách), výmena svietidiel za nové úsporné (hradené z vlastných finančných zdrojov SK) v súlade s platnou PD.Obe budovy majú bezbariérové vstupy, ktoré ostanú aj po realizácii projektu. Plánuje sa dosiahnu úspora energie na vykurovanie vo výke 76,60 % pre jedáleň a 76,10 % pre budovu koly; úspora energie na osvetlenie pre jedáleň bude 74,96 % a pre budovu koly 64,25 %; globálny ukazovatež primárnej energie pre jedáleň sa dostane na úroveň 111,67 kWh/(m2.a) a pre budovu koly 61,54 kWh/(m2.a) a taktie dôjde k zníeniu produkcií sledovaných emisií. Oba objekty budov sa dostanú po projekte do energetickej triedy B - nízkoenergetická budova (Slovak)
0 references
The present project is aimed at increasing the EHB of the Joint Colla ilina, and addresses shortcomings in the thermal, energy and hygiene areas. As part of the implementation, there will be 2 buildings (school dining room, building coles), where on the basis of processed EA it became clear that the objects exhibit insufficient thermal insulation properties, poor condition of lighting and distribution of CEC and TV, with a negative impact on increased energy and financial demand. The project will realise the replacement of fillings of openings, insulation of perimeter and fixed plains, secondary distribution of CK and TV with circulation, MaR heating (new distribution of heating and heating elements in buildings), replacement of luminaires for new energy saving (reserved from own financial resources SK) in accordance with valid PD.Obe buildings have barrier-free inputs, which will remain after the implementation of the project. Energy savings for heating are planned to be 76.60 % for the canteen and 76.10 % for the coke building; the energy saving for lighting for the canteen will be 74.96 % and for the wheel building 64.25 %; the global primary energy indicator for the canteen reaches 111.67 kWh/(m².a) and 61.54 kWh/(m².a) for the wheel building, thus reducing the production of monitored emissions. Both buildings reach energy class B after the project – low-energy building (English)
15 September 2021
0 references
Identifiers
310041A502
0 references