(10360.14072017.115000055) GALERI CASCINA (Q2056977)
Jump to navigation
Jump to search
Project in Italy financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | (10360.14072017.115000055) GALERI CASCINA |
Project in Italy financed by DG Regio |
Statements
105,768.02 Euro
0 references
358,535.64 Euro
0 references
29.5 percent
0 references
29 March 2018
0 references
29 March 2020
0 references
16 November 2020
0 references
COMUNE DI CASCINA
0 references
INTERVENTO 1: COIBENTAZIONE DEL SOLAIO RIVOLTO VERSO SOTTOTETTOPER DIMINUIRE LE DISPERSIONI ATTRAVERSO L?INVOLUCRO OPACO SI AGISCE SUL SOLAIO RIVOLTO VERSO AMBIENTI NON SCALDATI. L'INTERVENTO PREVEDE L'APPLICAZIONE DI PANNELLI DI POLISTIRENE ESPANSO SINTERIZZATO DI 10 CM (EPS, ?=0,033 W/MK). LO SPESSORE SCELTO CONSENTE AL PACCHETTO SOLAIO DI RAGGIUNGERE UNA TRASMITTANZA DI 0,23-0,24 W/M2KINTERVENTO 2: SOSTITUZIONE DELL?INVOLUCRO TRASPARENTEL'INTERVENTO PREVEDE LA SOSTITUZIONE DEGLI INFISSI CON ALTRI PI? PERFORMANTI, CON TELAIO IN PVC (PROFILO VUOTO; CON CINQUE CAMERE CAVE - TRASMITTANZA DEL TELAIO 1,20 W/M?K) E VETRO DOPPIO BASSO EMISSIVO CON INTERCAPEDINE CON GAS INERTE (EMISSIVIT? 0,05; INTERCAPEDINI CON GAS ARGON AL 90%; STRATIGRAFIA 4-20-4 - TRASMITTANZA DELLA PARTE VETRATA 1,20 W/M?K) PER UNA TRASMITTANZA COMPLESSIVA MEDIA PARI A CIRCA 1,3 W/M2KINTERVENTO 3: INSTALLAZIONE DI VALVOLE TERMOSTATICHE IN OGNI TERMINALE INSTALLAZIONE DI SISTEMI DI TERMOREGOLAZIONE IDONEI ALLE NUOVE TEC (Italian)
0 references
ACTION 1: INSULATION OF THE SOLENOID, WHICH IS DIRECTED TOWARDS A SUBSYSTEM TO REDUCE LEAKAGE THROUGH THE MATT ENVELOPE, SHALL ACT ON THE FLOOR INTENDED FOR NON-SCALABLE ENVIRONMENTS. DOES THE INTERVENTION PROVIDE FOR THE APPLICATION OF 10 CM SINTERED FOAM PANEL PANELS (EPS,? = 0,033 W/MK). THE CHOSEN THICKNESS OF THE PACKAGE ALLOWS THE SLAB TO ACHIEVE A TRANSMITTANCE OF 0,23-0,24 W/M2KINTERVENUTO 2: DO YOU INTEND TO REPLACE THE TRANSPARENTE-SPOT ENVELOPE WHEN REPLACING THE FIXTURES BY OTHER PI? PROOF OF PERFORMANCE, WITH PVC FRAME (EMPTY; WITH FIVE QUARRIES — TRANSMITTANCE OF FRAME 1,20 W/M? K) AND LOW EMISSION GLASS WITH GAP WITH INERT GAS (EMISSIVIT? 0,05; IRON CAVITY WITH 90 % OF THE GASES; STRATIGRAPHY 4-20-4 — LAMP TRANSMITTANCE 1,20 W/M? K) FOR AN OVERALL AVERAGE TRANSMITTANCE OF ABOUT 1,3 W/M2KINTERVENTO 3: INSTALLATION OF THERMOSTATIC CONTROL VALVES IN EACH TERMINAL INSTALLATION OF TEMPERATURE-CONTROL SYSTEMS SUITABLE FOR NEW TEC (English)
0 references
Identifiers
C57F18000050006
0 references