Complete energy modernisation of Hunyadi street store, solar panel installation (Q3932148)

From EU Knowledge Graph
Revision as of 21:49, 14 February 2022 by DG Regio (talk | contribs) (‎Changed an Item: fix budget)
Jump to navigation Jump to search
Project Q3932148 in Hungary
Language Label Description Also known as
English
Complete energy modernisation of Hunyadi street store, solar panel installation
Project Q3932148 in Hungary

    Statements

    0 references
    29,753,582.0 forint
    0 references
    84,113.38 Euro
    0.002827 Euro
    14 February 2022
    0 references
    59,507,164.0 forint
    0 references
    168,226.75 Euro
    0.002827 Euro
    14 February 2022
    0 references
    50.0 percent
    0 references
    16 September 2019
    0 references
    30 April 2021
    0 references
    Kovács Bálint egyéni vállalkozó
    0 references
    0 references

    46°12'54.14"N, 20°28'30.36"E
    0 references
    A Makó, Hunyadi u. 10. hrsz-ú 5559 ingatlan a múlt szád első felében épült masszív épület, viszont energetikai szempontból jelentős felújításra szorul.Az ingatlan elhelyezkedése piaci szempontból kedvező, a városközpontban helyezkedik el, a posta, intézmények lakótelepek ölelik körül..Támogatási kérelmünk szakmai megalapozása érdekében a Renema Kft ( Békéscsaba, Borjú u. 33.) energetikai szakértőt bíztuk meg az épület jelenlegi állapotának felmérésével, valamint a tervezett energetikai mutatók eléréséhez szükséges beruházások, azok paramétereinek meghatározására. Az elkészült szaktanulmány szerint épületünk jelenleg GG épületenergetikai besorolásba esik, amely átlagosnak felel meg. Megállapítást nyert, hogy indokolt a korszerűsítés, mely során az alábbi beruházások kivitelezése szükséges: - utólagos hőszigetelés a külső határoló falakon 15 cm EPS szigetelő anyaggal, a padlásfödémen esetében 20 cm kőzetgyapottal. - nyílászárók cseréje U=1,15 W/m2K egyenértékű szerkezeti elemekkel. Meglévő faablak szerkezet kicserélése az épület stílusával egyező egyedi gyártású faablak szerkezetre háromrétegű hőszigetelő üvegezéssel. - árnyékoló berendezések felszerelése, - teljes fűtési rendszer korszerűsítése: levegő-hőszivattyú telepítése, kondenzációs gázkazán telepítése, fan-coil hőleadókkal. A jelenlegi fűtés helyett egy VÍZ-LEVEGO hőszivattyú beépítésével megoldott fűtési rendszert tervezünk kialakítani. A fűtési rendszer szerelése során a radiátoros rendszert 55/45-os hőfoklépcsőre méretezzük. A meglévő fűtési rendszer teljes átgondolásával, korszerű fűtésszabályzók beépítésével és ahol lehet kihasználva felület fűtési lehetőségeket, továbbá a nyári hűtés biztosítása érdekében ( a meglévő spit klímák kiiktatása mellett) Fan-coil rendszerű hűtés kialakítása lesz biztosítva a levegő-hőszivattyú által. - napelemes rendszer kiépítése. Az épület méretéből, valamint többfunkciós mivoltából fakadóan a tervezett napelemes rendszer esetében feltétlen indokolt egy legalább 20 kW összteljesítményű rendszer beszerzése, annak érdekében, hogy közel a teljes energiaszükségletet megújuló energiaforrásból tudjuk fedezni. - mozgásérzékelő és energiatakarékos világítási testek beszerelése. Ezek együttes megvalósításával elérhető minősítés: BB (Közel nulla energiaigényre vonatkozó követelményeknek megfelelő). (Hungarian)
    0 references
    The 5559 property of Makó, Hunyadi u. 10 is a massive building built in the first half of your last mouth, but it needs to be renovated significantly from an energetic point of view. The location of the property is favourable from a market point of view, it is located in the city centre, surrounded by the postal and institutions housing estates. In order to establish the professional basis of our request for support, Renema Kft. (Békéscsaba, Borjú u. 33) has been commissioned to assess the current state of the building and to determine the necessary investments and parameters for achieving the planned energy indicators. According to the completed study, our building is currently classified as GG building energy, which corresponds to an average. It was found that the modernisation is justified, in which the following investments are required: — retrospective thermal insulation on external boundaries with 15 cm EPS insulating material, 20 cm in the case of the attic floor with rock wool. — replacement of doors and windows with equivalent structural elements U=1,15 W/m2K. Replacement of an existing wooden window structure with a custom-made wooden window structure that matches the style of the building with three layers of thermal insulation glazing. — installation of shielding devices, — modernisation of the entire heating system: installation of air-heat pump, installation of condensation gas boiler with fan-coil heat take-offs. Instead of the current heating system, we are planning to create a heating system by installing a heat pump. During the installation of the heating system, the radiator system is dimensioned to a temperature step 55/45. By rethinking the existing heating system, installing state-of-the-art heating controls and making use of surface heating options, and in order to ensure summer cooling (in addition to eliminating existing spit climates), Fan-coil cooling will be provided by the air-heat pump. — installation of a solar system. Due to the size and multifunctional nature of the building, it is absolutely necessary to purchase a system with a total power of at least 20 kW in the case of the planned solar system, in order to cover nearly the total energy demand from renewable sources. — installation of motion sensor and energy-saving lighting bodies. A rating that can be achieved by implementing them together: BB (meaning zero energy requirements). (English)
    8 February 2022
    0 references
    La propriété 5559 de Makó, Hunyadi u. 10 est un bâtiment massif construit dans la première moitié de votre dernière bouche, mais il a besoin d’être rénové de manière significative d’un point de vue énergétique. L’emplacement de la propriété est favorable du point de vue du marché, il est situé dans le centre-ville, entouré par les zones d’habitation postale et des institutions. Afin d’établir la base professionnelle de notre demande de soutien, Renema Kft. (Békéscsaba, Borjú u. 33) a été chargé d’évaluer l’état actuel du bâtiment et de déterminer les investissements et les paramètres nécessaires pour atteindre les indicateurs énergétiques prévus. Selon l’étude terminée, notre bâtiment est actuellement classé comme énergie du bâtiment GG, ce qui correspond à une moyenne. Il a été constaté que la modernisation est justifiée et que les investissements suivants sont nécessaires: — isolation thermique rétrospective sur les limites extérieures avec matériau isolant EPS de 15 cm, 20 cm dans le cas du plancher grenier avec de la laine de roche. — remplacement des portes et fenêtres par des éléments structurels équivalents U=1,15 W/m2K. Remplacement d’une structure de fenêtre en bois existante par une structure de fenêtre en bois sur mesure qui correspond au style du bâtiment par trois couches de vitrage isolant thermique. — installation de dispositifs de blindage, — modernisation de l’ensemble du système de chauffage: installation d’une pompe à chaleur-air, installation d’une chaudière à gaz de condensation avec décollages de chaleur à ventilo. Au lieu du système de chauffage actuel, nous prévoyons de créer un système de chauffage en installant une pompe à chaleur. Lors de l’installation du système de chauffage, le système de radiateur est dimensionné à une étape de température 55/45. En repensant le système de chauffage existant, en installant des commandes de chauffage à la fine pointe de la technologie et en utilisant des options de chauffage de surface, et afin d’assurer le refroidissement en été (en plus d’éliminer les climats de crache existants), le refroidissement du ventilateur sera assuré par la pompe à chaleur-air. — installation d’un système solaire. En raison de la taille et du caractère multifonctionnel du bâtiment, il est absolument nécessaire d’acheter un système d’une puissance totale d’au moins 20 kW dans le cas du système solaire prévu, afin de couvrir presque la demande totale d’énergie provenant de sources renouvelables. — installation d’un capteur de mouvement et de corps d’éclairage économes en énergie. Une note qui peut être obtenue en les mettant en œuvre ensemble: BB (c’est-à-dire zéro consommation d’énergie). (French)
    10 February 2022
    0 references
    Makó, Csongrád-Csanád
    0 references

    Identifiers

    GINOP-4.1.2-18-2019-00424
    0 references