(10360.14072017.115000056) (Q2056978)

From EU Knowledge Graph
Revision as of 09:58, 23 March 2020 by DG Regio (talk | contribs) (‎Created claim: summary (P836): ACTION 1: DOES THE OPERATION PROVIDE FOR THE APPLICATION OF POLYSTYRENE FOAM PANEL PANELS (EPS,? = 0,033 W/MK, 12 CM THICKNESS). THE SELECTED THICKNESS OF THE PACKAGE ALLOWS THE WALL PACKET TO ACHIEVE A TRANSMITTANCE OF 0,233 W/M2K, WHICH IS BELOW THE LIMIT LAID DOWN IN THE LEGISLATION OF 2: DOES THE INTERVENTION INCLUDE THE APPLICATION OF SINTERED POLYSTYRENE FOAM PANEL (EPS,? = 0,033 W/MK, THICKNESS 14 CM). THE SELECTED THICKNESS OF THE PACKAG...)
Jump to navigation Jump to search
Project in Italy financed by DG Regio
Language Label Description Also known as
English
(10360.14072017.115000056)
Project in Italy financed by DG Regio

    Statements

    0 references
    90,645.24 Euro
    0 references
    307,272.0 Euro
    0 references
    29.5 percent
    0 references
    29 March 2018
    0 references
    29 March 2020
    0 references
    16 November 2020
    0 references
    COMUNE DI CASCINA
    0 references
    0 references

    43°46'11.53"N, 11°15'20.09"E
    0 references
    INTERVENTO 1: COIBENTAZIONE DELLE PARETI PERIMETRALIL'INTERVENTO PREVEDE L'APPLICAZIONE DI PANNELLI DI POLISTIRENE ESPANSO SINTERIZZATO (EPS, ?=0,033 W/MK, SPESSORE 12 CM). LO SPESSORE SCELTO CONSENTE AL PACCHETTO MURARIO DI RAGGIUNGERE UNA TRASMITTANZA DI 0,233 W/M2K, INFERIORE AL LIMITE PREVISTO DALLA LEGISLAZIONE VIGENTE.INTERVENTO 2: COIBENTAZIONE DEL SOLAIO DI COPERTURAL'INTERVENTO PREVEDE L'APPLICAZIONE DI PANNELLI DI POLISTIRENE ESPANSO SINTERIZZATO (EPS, ?=0,033 W/MK, SPESSORE 14 CM). LO SPESSORE SCELTO CONSENTE AL PACCHETTO MURARIO DI RAGGIUNGERE UNA TRASMITTANZA DI 0,208 W/M2K, INFERIORE AL LIMITE PREVISTO DALLA LEGISLAZIONE VIGENTE.INTERVENTO 3: COIBENTAZIONE DEL SOLAIO RIVOLTO VERSO SOTTOTETTO NON SCALDATO L'INTERVENTO PREVEDE L'APPLICAZIONE DI PANNELLI DI POLISTIRENE ESPANSO SINTERIZZATO (EPS, ?=0,033 W/MK, SPESSORE 10 CM). LO SPESSORE SCELTO CONSENTE AL PACCHETTO MURARIO DI RAGGIUNGERE UNA TRASMITTANZA DI 0,27 W/M2K, INFERIORE AL LIMITE PREVISTO DALLA LEGISLAZIONE VIGENTE (Italian)
    0 references
    ACTION 1: DOES THE OPERATION PROVIDE FOR THE APPLICATION OF POLYSTYRENE FOAM PANEL PANELS (EPS,? = 0,033 W/MK, 12 CM THICKNESS). THE SELECTED THICKNESS OF THE PACKAGE ALLOWS THE WALL PACKET TO ACHIEVE A TRANSMITTANCE OF 0,233 W/M2K, WHICH IS BELOW THE LIMIT LAID DOWN IN THE LEGISLATION OF 2: DOES THE INTERVENTION INCLUDE THE APPLICATION OF SINTERED POLYSTYRENE FOAM PANEL (EPS,? = 0,033 W/MK, THICKNESS 14 CM). THE SELECTED THICKNESS OF THE PACKAGE ALLOWS THE WALL PACKET TO ACHIEVE A TRANSMITTANCE OF 0,208 W/M2K, WHICH IS BELOW THE LIMIT LAID DOWN IN THE LEGISLATION OF 3: SOCKET INSULATION FOR THE NON-HEATED SUB-FLOOR OF THE INTERVENTION, THE OPERATION PROVIDES FOR THE APPLICATION OF SINTERED POLYSTYRENE FOAM PANEL PANELS (EPS,? = 0,033 W/MK, THICKNESS 10 CM). THE THICKNESS CHOSEN ALLOWS THE WALL PACKET TO ACHIEVE A TRANSMITTANCE OF 0,27 W/M2K, WHICH IS BELOW THE LIMIT PROVIDED FOR IN THE LEGISLATION IN FORCE. (English)
    0 references

    Identifiers