LOW-COST ENGINE-FES HYBRID ORTHESIS FOR WALKING OF MEDULLAR INJURIES AND SIMULATION METHODS TO ASSIST DESIGN AND ADAPTATION (Q3156073)

From EU Knowledge Graph
Revision as of 15:57, 12 October 2021 by DG Regio (talk | contribs) (‎Removed claim: summary (P836): APPLICANTS HAVE BEEN WORKING FOR MORE THAN FIVE YEARS ON THE DEVELOPMENT OF LOW-COST KNEE-TONKLE-FOOT ACTIVE ORTHESIS FOR THE MARCH OF SPINAL INJURIES, HAVING REACHED A PROTOTYPE THAT USES AN ELECTRIC MOTOR TO MOVE THE KNEE DURING THE SWING AND BLOCK IT DURING THE SUPPORT, WHOSE PERFORMANCE IS CONTROLLED ACCORDING TO THE ROTATION OF THE ANKLE OF THE OPPOSITE FOOT (MEASURED WITH ENCODER) AND THE SUPPORT STATE (MEASURED WITH PLANTAR PRESSURE SEN...)
Jump to navigation Jump to search
Project Q3156073 in Spain
Language Label Description Also known as
English
LOW-COST ENGINE-FES HYBRID ORTHESIS FOR WALKING OF MEDULLAR INJURIES AND SIMULATION METHODS TO ASSIST DESIGN AND ADAPTATION
Project Q3156073 in Spain

    Statements

    0 references
    53,530.4 Euro
    0 references
    66,913.0 Euro
    0 references
    80.0 percent
    0 references
    1 January 2016
    0 references
    31 December 2018
    0 references
    UNIVERSIDADE DA CORUÑA
    0 references
    0 references

    43°29'4.88"N, 8°13'59.38"W
    0 references
    15036
    0 references
    LOS SOLICITANTES LLEVAN MAS DE CINCO AÑOS TRABAJANDO EN EL DESARROLLO DE ORTESIS ACTIVAS DE RODILLA-TOBILLO-PIE DE BAJO COSTE PARA LA MARCHA DE LESIONADOS MEDULARES, HABIENDO LLEGADO A UN PROTOTIPO QUE UTILIZA UN MOTOR ELECTRICO PARA MOVER LA RODILLA DURANTE EL BALANCEO Y BLOQUEARLA DURANTE EL APOYO, CUYA ACTUACION SE CONTROLA EN FUNCION DEL GIRO DEL TOBILLO DEL PIE CONTRARIO (MEDIDO CON ENCODER) Y DEL ESTADO DE APOYO (MEDIDO CON SENSORES DE PRESION PLANTAR). EL SISTEMA ES PORTABLE MEDIANTE UNA MOCHILA QUE LLEVA EL USUARIO, EN LA QUE SE UBICAN UN PEQUEÑO ORDENADOR, LA TARJETA DE ADQUISICION, LOS DRIVERS DE LOS MOTORES Y LA BATERIA. UNA PACIENTE LESIONADA MEDULAR HA COLABORADO CON EL EQUIPO DURANTE TODO EL TIEMPO DE DESARROLLO Y, DESDE PRINCIPIOS DE ESTE AÑO, ESTA SIENDO SOMETIDA AL PROCESO DE ADAPTACION A LAS ORTESIS._x000D_ EL PROYECTO QUE SE SOLICITA PRETENDE AVANZAR EN EL DESARROLLO DE LAS ORTESIS ACTIVAS MENCIONADAS SEGUN LAS SIGUIENTES DIRECCIONES: 1) MEJORAR EL DISPOSITIVO EXISTENTE, AUMENTANDO SU ROBUSTEZ (MENOS SENSORES Y MAS FIABLES), PORTABILIDAD (REDUCCION DEL EQUIPAMIENTO NECESARIO), USABILIDAD (FACILITAR TRANSICIONES) Y EFICIENCIA (REDUCCION DEL CONSUMO ENERGETICO); 2) INTRODUCIR LA ELECTROESTIMULACION FUNCIONAL (FES) EN EL DISPOSITIVO, FUENTE DE MUCHOS BENEFICIOS PARA EL PACIENTE, CONTEMPLANDO SU INTEGRACION CON LA ACTUACION DEL MOTOR; 3) ESTUDIAR LA UTILIDAD PARA USUARIOS CON DISTINTOS NIVELES DE LESION, AMPLIANDO EL NUMERO DE PACIENTES, DE MANERA QUE SE PUEDA ESTABLECER UN PROTOCOLO PARA EL PROCESO DE ADAPTACION, TAN IMPORTANTE PARA EL EXITO DEL DISPOSITIVO COMO LAS PROPIAS CARACTERISTICAS TECNICAS DEL MISMO; 4) PROFUNDIZAR EN LA UTILIZACION DE METODOS DE SIMULACION DE APOYO AL DISEÑO Y LA ADAPTACION, ABORDANDO EL ANALISIS Y LA PREDICCION DE MOVIMIENTO MEDIANTE MODELOS NEURO-MUSCULO-ESQUELETICOS SUJETO-ORTESIS PERSONALIZADOS. (Spanish)
    0 references
    Ferrol
    0 references

    Identifiers

    DPI2015-65959-C3-1-R
    0 references