Thermal rehabilitation of housing blocks in Rm. Valcea: Block B2, Block A6, Block N4, Block N5, Block 9 (Q2744334): Difference between revisions
Jump to navigation
Jump to search
(Changed label, description and/or aliases in en: translated_label) |
(Changed an Item: Edited by the beneficiary bot - attach the beneficiary based on the string) |
||
Property / beneficiary | |||
Q2754317 (Deleted Item) | |||
Property / beneficiary: Q2754317 (Deleted Item) / rank | |||
Normal rank |
Revision as of 11:58, 21 June 2021
Project Q2744334 in Romania
Language | Label | Description | Also known as |
---|---|---|---|
English | Thermal rehabilitation of housing blocks in Rm. Valcea: Block B2, Block A6, Block N4, Block N5, Block 9 |
Project Q2744334 in Romania |
Statements
3,397,033.3 Romanian Leu
0 references
6,660,849.6 Romanian Leu
0 references
0.51 percent
0 references
1 March 2014
0 references
30 April 2020
0 references
UAT Ramnicu Valcea
0 references
Q2754317 (Deleted Item)
0 references
Lucrari care se vor executa: izolare termica a peretilor exteriori cu un strat de polistiren expandat ignifugat de 10 cm pe partea exterioara; inlocuirea ferestrelor si usilor existente cu ferestre tip termopan cu tamplarie de PVC cu 5 camere); inchiderea tuturor balcoanelor, inclusiv izolarea parapetilor de beton sau profile metalice si montare de tamplarie PVC tip termopan; inlocuirea si izolarea conductelor de distributie din subsol si montarea de robinete de reglare pe racordul retur; montarea conductei de recirculare pentru apa calda menajera; montarea de contoare energetice la reteaua de termoficare. (Romanian)
0 references
Works that will be executed: thermal insulation of the exterior walls with an expanded flame retardant polystyrene layer of 10 cm on the outside; replacing existing windows and doors with double-glazed windows with 5-room PVC carpentry); closing of all balconies, including insulation of concrete parapets or metallic profiles and mounting of PVC carpentry type thermo resistant; replacement and insulation of distribution pipes in the basement and mounting of adjusting taps on the return connection; installation of the recirculation pipe for domestic hot water; installation of energy meters to the district heating network. (English)
17 June 2021
0 references
VL, Localizare proiect: Regiunea Sud – Vest Oltenia, Mun. Rm. Valcea, jud. Valcea1. Blocul de locuinţa B2 - Aleea Primaverii nr.6,2. Blocul de locuinta A6 - Strada Crinilor nr.2,3. Blocul de locuinta N4 - Aleea Mioritei nr.3, 4. Blocul de locuinta N5 - Aleea Mioritei nr.2, 5. Blocul de locuinta 9 - Calea lui Traian nr. 179
0 references
Identifiers
117070
0 references