Improvement of the wastewater management in the metropolitan area of the metropolitan area (Q85206): Difference between revisions
Jump to navigation
Jump to search
(Changed an Item) |
(Removed claim: EU contribution (P835): 10,613,137.699199999 euro) |
||||||||||||||
Property / EU contribution | |||||||||||||||
| |||||||||||||||
Property / EU contribution: 10,613,137.699199999 Euro / rank | |||||||||||||||
Property / EU contribution: 10,613,137.699199999 Euro / qualifier | |||||||||||||||
| |||||||||||||||
Property / EU contribution: 10,613,137.699199999 Euro / qualifier | |||||||||||||||
|
Revision as of 18:34, 23 September 2020
Project in Poland financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | Improvement of the wastewater management in the metropolitan area of the metropolitan area |
Project in Poland financed by DG Regio |
Statements
44,221,407.08 zloty
0 references
52,025,184.81 zloty
0 references
85.0 percent
0 references
1 January 2015
0 references
31 December 2020
0 references
WODOCIĄGI KIELECKIE SP. Z O.O.
0 references
Projekt realizowany na terenie miasta Kielce, gminy Masłów, gminy Sitkówka Nowiny. Zakres rzeczowy obejmuje: -wybudowanie sieci kanalizacji sanitarnej - 38,9 km, -wyremontowanie kanalizacji sanitarnej - 3,5 km, -wybudowanie sieci wodociągowej - 2,7 km, -wyremontowanie sieci wodociągowej - 11,2 km, -wymiana generatora biogazowego na terenie OŚ Sitkówka, -przebudowa stacji uzdatniania gazu na OŚ, - zakupu i montażu wirówki zagęszczającej, -modernizacji membranowego zbiornika gazu na OŚ, -rozbudowa zintegrowanego systemu monitoringu i zarządzania sieciami wodkan typu SCADA, -zakup samochodów specjalistycznych (do przewozu osadu oraz do czyszczenia kanalizacji) (Polish)
0 references
Project carried out in the city of Kielce, the municipality of Maasan, the municipality of Sitkówka Nowiny.The material scope consists of:— Construction of a sanitary sewage system — 38.9 km, -renovation of the sanitary sewage system — 3.5 km, -construction of a water supply network — 2.7 km, -renovation of the water supply network — 11.2 km, -replacement of a biogas generator on the premises of the Sitkówka WWTP, -renewal of a gas treatment station for the WIOŚ, — extension of the membrane of a gas tank to the WWTP, extension of the integrated system for monitoring and managing the sewerage system of the SCADA type, -purchase of specialised cars (for the transportation of sludge and for cleaning of the sewerage system) (English)
0 references
Identifiers
POIS.02.03.00-00-0028/17
0 references