Energy renovation of the municipal building in Lucakawa and in the building of the Group of Schools in Jasionka (Q118672): Difference between revisions
Jump to navigation
Jump to search
(Removed claims) |
(Changed an Item) |
||||||||||||||
Property / budget | |||||||||||||||
511,359.97 zloty
| |||||||||||||||
Property / budget: 511,359.97 zloty / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / budget | |||||||||||||||
122,726.39 Euro
| |||||||||||||||
Property / budget: 122,726.39 Euro / rank | |||||||||||||||
Preferred rank | |||||||||||||||
Property / budget: 122,726.39 Euro / qualifier | |||||||||||||||
exchange rate to Euro: 0.24 Euro
| |||||||||||||||
Property / budget: 122,726.39 Euro / qualifier | |||||||||||||||
point in time: 13 January 2020
|
Revision as of 20:55, 22 June 2020
Project in Poland financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | Energy renovation of the municipal building in Lucakawa and in the building of the Group of Schools in Jasionka |
Project in Poland financed by DG Regio |
Statements
434,655.92 zloty
0 references
511,359.97 zloty
0 references
85.0 percent
0 references
23 March 2016
0 references
31 October 2017
0 references
GMINA TRZEBOWNISKO
0 references
Projekt obejmuje zadania inwestycyjne polegające na wykonaniu prac termomodernizacyjnych w 2 budynkach użyteczności publicznej zlokalizowanych w gminie Trzebownisko : 1. Budynek użyteczności publicznej w Łukawcu, 2. Budynek Zespołu Szkół w Jasionce, Dotychczasowy stan techniczny i energetyczny budynków objętych projektem jest dalece niezadowalający. Budynki wykazują znaczne straty energii cieplnej co spowodowane jest nieocieplonymi ścianami, stropami i nieefektywnym systemem cieplnym. W budynku komunalnym w Łukawcu zaplanowano:- izolacja ścian budynku styropianem o współczynniku przewodzenia ciepła ? = 0,033 W/(m*K),- ocieplenie stropodachu płytami wełny mineralnej o współczynniku przewodzenia ciepła ? = 0,035 W/(m*K), - wymiana starych okien na nowe o współczynniku przenikania ciepła nie gorszym niż U = 0,9 W/(m2*K), - wymiana starych drzwi na nowe o współczynniku przenikania ciepła nie gorszym niż U = 1,3 W/(m2*K), -modernizacja systemu CWU. Likwidacja lokalnych podgrzewaczy elektrycznych i montaż centralnej instalacji CWU zasilanej z kotła gazowego,- modernizacja systemu grzewczego. W budynku Zespołu Szkół w Jasionce zaplanowano:- ocieplenie stropu zewnętrznego (poddasze) płytami wełny mineralnej o współczynniku przewodzenia ciepła ? = 0,033 W/(m*K),- wymiana starych drzwi zewnętrznych na nowe o współczynniku przenikania ciepła nie gorszym niż U = 1,3 W/(m2*K), - wymiana starych okien zewnętrznych na nowe o współczynniku przenikania ciepła nie gorszym niż U = 0,9 W/(m2*K).Realizacja inwestycji pozwoli na uzyskanie:1. W budynku komunalnym w Łukawcu wskaźnika EP na poziomie 202,95 [kWh/m2/rok] oraz zostanie zmniejszone zapotrzebowanie na zużycie energii o 77%,2. W budynku ZS w Jasionce wskaźnika EP na poziomie 198,40 [kWh/m2/rok] oraz zostanie zmniejszone zapotrzebowanie na zużycie energii o 25%, W wyniku projektu prace termomodernizacyjne przeprowadzone zostaną w dwóch budynkach o łącznej kubaturze 15 961,08 m3. (Polish)
0 references
The project consists of investment tasks consisting of the completion of thermal modernisation works in 2 public buildings located in the municipality of Trzebowlow: 1. Public amenity building in Lucatecu, 2. A building group building in the Jasionka School, the current technical and energy condition of the buildings covered by the project is very unsatisfactory. Buildings show a significant loss of heat as a result of non-insulated walls, ceilings and an inefficient thermal system. The following is planned in the municipal building in Lukawica: — the insulation of the building wall with a heat leadership coefficient? = 0,033 W/(m * K), — warming up of the mineral wool sheet with a heat conduction coefficient? = 0,035 W/(m * K), — replacement of old windows with new heat transfer factors no worse than U = 0,9 W/(m² * K), — replacement of old doors with a new heat transfer coefficient of not less than U = 1,3 W/(m² * K), The dismantling of local electric heaters and the installation of a central installation of CWU powered by a gas boiler, — modernisation of the heating system. In the building of the School Complex in Jasionka, “- insulation of the outer ceiling (lighter) of mineral wool plates with a thermal conductivity is planned? = 0,033 W/(m * K), — replacement of old external doors with a new heat transfer coefficient of not less than U = 1,3 W/(m² * K), — replacement of old external windows with new heat transfer factors not worse than U = 0,9 W/(m² * K).Implementation of the investment will enable: 1. The EP level 202,95 [kWh/m²/year] will be reduced by 77 % for energy consumption and 2 for energy consumption. In the ZS building in Jasionka, the ‘EP’ ratio of 198,40 [kWh/m²/year] and a reduced energy consumption demand of 25 % will be reduced, as a result of the project, energy efficiency works will be carried out in two buildings with a total volume of 15 961.08 m³. (English)
0 references
Identifiers
RPPK.03.02.00-18-0037/16
0 references