RENOVATION AND ENERGY EFFICIENCY OF THE ARENA. MEASURES ON THE BUILDING ENVELOPE AND THE CONSTRUCTION OF THERMAL INSTALLATIONS, ELECTRIC LIGHTING AND LIGHTING (Q2023510): Difference between revisions
Jump to navigation
Jump to search
(Changed an Item) |
(Created claim: summary (P836): REMOVAL AND REPLACEMENT OF ROOF SHEETS IN STATE OF DILAPIDATED OR DAMAGED PLATES, LAYING OF A LAYER OF INSULATING SUNLIGHT FOR THE INSULATION OF SUNLIGHT AND OF A PAINT WITH A HIGH RESISTANCE VARNISH FOR THE PROTECTION OF UV RADIATION, THE EXECUTION OF STRUCTURES FOR RAIN-PIPES AND VENTILATION OF ALUMINIUM, INTERVENTION ON THE PERIMETER WALLS (HUMIDIFICATION OF MASONRY, APPLICATION OF A CHEMICAL BARRIER TO THE EXTERNAL BASE AND LAYING OF A NETWO...) |
||
Property / summary | |||
REMOVAL AND REPLACEMENT OF ROOF SHEETS IN STATE OF DILAPIDATED OR DAMAGED PLATES, LAYING OF A LAYER OF INSULATING SUNLIGHT FOR THE INSULATION OF SUNLIGHT AND OF A PAINT WITH A HIGH RESISTANCE VARNISH FOR THE PROTECTION OF UV RADIATION, THE EXECUTION OF STRUCTURES FOR RAIN-PIPES AND VENTILATION OF ALUMINIUM, INTERVENTION ON THE PERIMETER WALLS (HUMIDIFICATION OF MASONRY, APPLICATION OF A CHEMICAL BARRIER TO THE EXTERNAL BASE AND LAYING OF A NETWORK OF GLASS FIBRE WITH FIXED CAP PRIMERS, CONSTRUCTION AND FITTING OF A COAT OF GLASS FIBRE WITH A CAP OF 30 CM THICK TO THE FOUR SIDES OF THE SPACE TO CONTAIN THE GROUND), ELECTRICAL SYSTEMS (NEW ELECTRICAL SWITCHBOARDS FOR TRIGENERATION, UTA AND SIST SYSTEMS) (English) | |||
Property / summary: REMOVAL AND REPLACEMENT OF ROOF SHEETS IN STATE OF DILAPIDATED OR DAMAGED PLATES, LAYING OF A LAYER OF INSULATING SUNLIGHT FOR THE INSULATION OF SUNLIGHT AND OF A PAINT WITH A HIGH RESISTANCE VARNISH FOR THE PROTECTION OF UV RADIATION, THE EXECUTION OF STRUCTURES FOR RAIN-PIPES AND VENTILATION OF ALUMINIUM, INTERVENTION ON THE PERIMETER WALLS (HUMIDIFICATION OF MASONRY, APPLICATION OF A CHEMICAL BARRIER TO THE EXTERNAL BASE AND LAYING OF A NETWORK OF GLASS FIBRE WITH FIXED CAP PRIMERS, CONSTRUCTION AND FITTING OF A COAT OF GLASS FIBRE WITH A CAP OF 30 CM THICK TO THE FOUR SIDES OF THE SPACE TO CONTAIN THE GROUND), ELECTRICAL SYSTEMS (NEW ELECTRICAL SWITCHBOARDS FOR TRIGENERATION, UTA AND SIST SYSTEMS) (English) / rank | |||
Normal rank |
Revision as of 09:41, 23 March 2020
Project in Italy financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | RENOVATION AND ENERGY EFFICIENCY OF THE ARENA. MEASURES ON THE BUILDING ENVELOPE AND THE CONSTRUCTION OF THERMAL INSTALLATIONS, ELECTRIC LIGHTING AND LIGHTING |
Project in Italy financed by DG Regio |
Statements
1,103,359.83 Euro
0 references
1,471,146.44 Euro
0 references
75.0 percent
0 references
26 September 2014
0 references
22 August 2018
0 references
COMUNE DI PIEDIMONTE MATESE
0 references
RIMOZIONE E SOSTITUZIONE SUI TETTI DELLE LAMIERE IN STATO DI FATISCENZA O DANNEGGIATE, POSA DI UNO STRATO MATERIALE ISOLANTE TERMOACUSTICO PER L'ISOLAMENTO DEL LASTRICO SOLARE E DI UNA VERNICE AD ALTA RESISTENZA PER PROTEZIONE DEI RAGGI UV, ESECUZIONE DI OPERE ALLE PLUVIALI E CANNE DI VENTILAZIONE IN ALLUMINIO, INTERVENTI ALLE PARETI PERIMETRALI (DEUMIDIFICAZIONE MURATURA, APPLICAZIONE BARRIERA CHIMICA ALLA BASE ESTERNA E POSA DI UNA RETE IN FIBRA DI VETRO CON PRIMER FISSATIVO COMBINATO, REALIZZAZIONE E POSA DI UN CAPPOTTO ALLE PARETI PERIMETRALI), INFISSI INTERNI ED ESTERNI (PORTONCINO BLINDATO E INFISSI ESTERNI, DOTATI DI TRIPLO VETROCAMERA BASSO-EMISSIVO), OPERE STRUTTURALI (REALIZZAZIONE DI UN LOCALE TECNICO IN CONGLOMERATO CEMENTIZIO ARMATO, PER UN'ALTEZZA COMPLESSIVA DI M 3,70 DA INTERRO E SETTI DELLO SPESSORE DI 30 CM AI QUATTRO LATI DEL LOCALE PER CONTENERE LA SPINTA DEL TERRENO), IMPIANTI ELETTRICI (NUOVI QUADRI ELETTRICI DI ALIMENTAZIONE SISTEMA DI TRIGENERAZIONE, UTA E SISTE (Italian)
0 references
REMOVAL AND REPLACEMENT OF ROOF SHEETS IN STATE OF DILAPIDATED OR DAMAGED PLATES, LAYING OF A LAYER OF INSULATING SUNLIGHT FOR THE INSULATION OF SUNLIGHT AND OF A PAINT WITH A HIGH RESISTANCE VARNISH FOR THE PROTECTION OF UV RADIATION, THE EXECUTION OF STRUCTURES FOR RAIN-PIPES AND VENTILATION OF ALUMINIUM, INTERVENTION ON THE PERIMETER WALLS (HUMIDIFICATION OF MASONRY, APPLICATION OF A CHEMICAL BARRIER TO THE EXTERNAL BASE AND LAYING OF A NETWORK OF GLASS FIBRE WITH FIXED CAP PRIMERS, CONSTRUCTION AND FITTING OF A COAT OF GLASS FIBRE WITH A CAP OF 30 CM THICK TO THE FOUR SIDES OF THE SPACE TO CONTAIN THE GROUND), ELECTRICAL SYSTEMS (NEW ELECTRICAL SWITCHBOARDS FOR TRIGENERATION, UTA AND SIST SYSTEMS) (English)
0 references
Identifiers
D17H13002260008
0 references