Building energy development for the use of renewable energy at K.Z.L. Kft. (Q3935495): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Removed claims)
(‎Changed an Item: fix budget)
Property / co-financing rate
 
55.0 percent
Amount55.0 percent
Unitpercent
Property / co-financing rate: 55.0 percent / rank
 
Normal rank
Property / budget
 
4,024,269.0 forint
Amount4,024,269.0 forint
Unitforint
Property / budget: 4,024,269.0 forint / rank
 
Normal rank
Property / budget
 
11,376.61 Euro
Amount11,376.61 Euro
UnitEuro
Property / budget: 11,376.61 Euro / rank
 
Preferred rank
Property / budget: 11,376.61 Euro / qualifier
 
exchange rate to Euro: 0.002827 Euro
Amount0.002827 Euro
UnitEuro
Property / budget: 11,376.61 Euro / qualifier
 
point in time: 13 February 2022
Timestamp+2022-02-13T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0
Property / EU contribution
 
2,213,347.0 forint
Amount2,213,347.0 forint
Unitforint
Property / EU contribution: 2,213,347.0 forint / rank
 
Normal rank
Property / EU contribution
 
6,257.13 Euro
Amount6,257.13 Euro
UnitEuro
Property / EU contribution: 6,257.13 Euro / rank
 
Preferred rank
Property / EU contribution: 6,257.13 Euro / qualifier
 
exchange rate to Euro: 0.002827 Euro
Amount0.002827 Euro
UnitEuro
Property / EU contribution: 6,257.13 Euro / qualifier
 
point in time: 13 February 2022
Timestamp+2022-02-13T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0

Revision as of 11:44, 13 February 2022

Project Q3935495 in Hungary
Language Label Description Also known as
English
Building energy development for the use of renewable energy at K.Z.L. Kft.
Project Q3935495 in Hungary

    Statements

    0 references
    0 references
    2,213,347.0 forint
    0 references
    6,257.13 Euro
    0.002827 Euro
    13 February 2022
    0 references
    4,024,269.0 forint
    0 references
    11,376.61 Euro
    0.002827 Euro
    13 February 2022
    0 references
    55.0 percent
    0 references
    6 November 2020
    0 references
    5 November 2021
    0 references
    K.Z.L. Korlátolt Felelősségű Társaság
    0 references
    0 references

    47°13'44.83"N, 16°37'7.54"E
    0 references
    A vállalkozás esetében a szakemberek által végzett számítások alapján 12 kWp-es napelemes rendszer Canadian Solar 300 W(p) panel típusú napelemes rendszer telepítése szükséges. A telepíteni kívánt napelem rendszer műszaki tartalma: 40 db Canadian Solar 300 W(p) panel: - max. teljesítmény: 300 W - üzemi feszültség: 32,7 V - üzemi áram: 9,18 A - cella típus: polikristály - méretek: 1675x992x35 mm SolarEdge SE 10K inverter: - névleges AC teljesítmény: 10.000 VA - névleges DC teljesítmény: 13.500 VA - max. bemeneti áramerősség: 16,5 Adc - méretek: 540x315x191 mm 40 db SolarEdge optimalizáló + wifi Ferde tetőre szerelt tartószerkezet. A kiserőmű csatlakozási teljesítménye nem haladja meg az 50 kVA-t. A HMKE létesítése hatósági engedélyhez nem kötött. A napelemes berendezés tartalmazza a napelem elhelyezéséhez szükséges tartószerkezetet, valamint a rendszer üzemképesre szereléséhez és hálózatra kapcsolásához szükséges egyéb anyagokat. A projektet megelőzően a szakemberek helyszíni felméréseket végeztek. Statikus ellenőrizte az épület teherbíró képességét. A telepítendő rendszer esetében fontos szempontok voltak a garanciális, szervizelési, megbízhatósági és teljesítménybeli elemek. A kivitelezést, megbízható, felkészült szakemberek fogják végezni. A napelemes rendszer nem csak anyagi megtérülést jelent, hanem hozzájárul a környezettudatos gazdálkodás végzéséhez. Az ingatlan előző évi összes villamos energia felhasználása: 14.797 kWh. Az épület tervezett villamos energia felhasználsa: 1.597 kWh. Elektromos fogyasztás összes primer energia felhasználása az eredeti állapotban: 36.992,5 Gj. A tervezett állapot energiafelhasználása 5,7492 GJ. A meglévő állapot szerinti CO2 kibocsátás mértéke: 11,132 t/év. A tervezett állapot CO2 kibocsátása: 1,20 t/év. A tervezett napelem villamos energia hozama: 13.200 kWh/év, primer energia termelése: 33.000 kWh/év. A primer energia megtakarítás mértéke %-ban: 89,21 %. A rendszer az épület tetőszerkezetének a nap által legsütöttebb oldalára kerül felhelyezésre, ezzel is biztosítva a napelemek ideális termelésének elősegítését. A tetőszerkezet típusa: ferdetető. (Hungarian)
    0 references
    In the case of the enterprise, according to calculations made by professionals, 12 kWp solar system is required to install Canadian Solar 300 W(p) panel type solar panel system. Technical content of the solar panel system you want to install: 40 Pcs Canadian Solar 300 W(p) Panel: — max. power: 300 W — operating voltage: 32,7 V — operating current: 9.18 A — cell type: polycrystal — dimensions: 1675x992x35 mm SolarEdge SE 10K inverter: — rated AC power: 10.000 VA — rated DC power: 13.500 VA — max. input current: 16.5 Adc — dimensions: 540x315x191 mm 40 pcs SolarEdge Optimiser + Wi-Fi Ferde Roof Mounted Holder. The connection power of the small power plant does not exceed 50 kVA. The construction of the HMKE is not subject to official authorisation. The solar panel equipment includes the support structure required for the installation of the solar panel, as well as other materials necessary for installing the system and connecting it to the network. Prior to the project, on-the-spot surveys were carried out by experts. Static checked the building’s carrying capacity. Warranty, servicing, reliability and performance elements were important aspects of the system to be installed. The construction will be carried out by reliable, well-trained professionals. The solar system not only represents a financial return, but also contributes to environmentally conscious management. Total electricity consumption of the property in the previous year: 14.797 kWh. Use of planned electricity in the building: 1.597 kWh. Electric consumption of total primary energy in the original state: 36.992.5 Gj. The energy consumption of the planned state is 5,7492 GJ. Level of CO2 emissions as existing: 11,132 tons/year. Planned state CO2 emissions: 1,20 tons/year. Electricity output of the planned solar panel: 13.200 kWh/year, primary energy production: 33.000 kWh/year. Primary energy savings in %: 89.21 %. The system is placed on the brightest side of the roof of the building, ensuring the ideal production of solar panels. Type of roof structure: it’s a slanting. (English)
    8 February 2022
    0 references
    Dans le cas de l’entreprise, selon les calculs effectués par les professionnels, le système solaire de 12 kWp est nécessaire pour installer le système de panneau solaire canadien de type panneau solaire 300 W(p). Contenu technique du système de panneaux solaires que vous souhaitez installer: 40 PC Canadian Solar 300 W(p) Panneau: — puissance maximale: 300 W — tension de fonctionnement: 32,7 V — courant de fonctionnement: 9.18 A — type de cellule: polycristal — dimensions: Onduleur SolarEdge SE 10K de 1675x992x35 mm: — puissance nominale AC: 10.000 VA — puissance nominale CC: 13.500 VA — courant d’entrée max.: 16.5 Adc — dimensions: 540x315x191 mm 40 pcs SolarEdge Optimizer + support de toit Wi-Fi Ferde. La puissance de raccordement de la petite centrale ne dépasse pas 50 kVA. La construction du HMKE n’est pas soumise à autorisation officielle. L’équipement du panneau solaire comprend la structure de support nécessaire à l’installation du panneau solaire, ainsi que d’autres matériaux nécessaires à l’installation du système et à sa connexion au réseau. Avant le projet, des enquêtes sur place étaient réalisées par des experts. Statique a vérifié la capacité de charge du bâtiment. Les éléments de garantie, d’entretien, de fiabilité et de performance étaient des aspects importants du système à installer. La construction sera réalisée par des professionnels fiables et bien formés. Le système solaire représente non seulement un rendement financier, mais contribue également à une gestion respectueuse de l’environnement. Consommation totale d’électricité de la propriété au cours de l’année précédente: 14,797 kWh. Utilisation de l’électricité prévue dans le bâtiment: 1,597 kWh. Consommation électrique d’énergie primaire totale dans l’état d’origine: 36.992.5 Gj. La consommation d’énergie de l’état prévu est de 5,7492 GJ. Niveau d’émissions de CO2 tel qu’il existe: 11 132 tonnes/an. Émissions de CO2 prévues par l’État: 1,20 tonnes/an. Production d’électricité du panneau solaire prévu: 13,200 kWh/an, production d’énergie primaire: 33,000 kWh/an. Économies d’énergie primaire en %: 89,21 %. Le système est placé sur le côté le plus lumineux du toit du bâtiment, assurant la production idéale de panneaux solaires. Type de structure de toit: C’est un penchant. (French)
    10 February 2022
    0 references
    Szombathely, Vas
    0 references

    Identifiers

    GINOP-4.1.4-19-2020-02606
    0 references