Boiler economiser (Q3163058): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Removed claim: summary (P836): The function of the economiser is to recover the existing heat in the discharge fumes by heating the water that comes from the mother tank approximately from 90 °C to 110 °C, and from the same to charge to the boiler. Currently this water is heated with one of the existing gas boilers; therefore, such consumption will no longer be necessary with the new installation. _x000D_ the project will allow to increase the steady performance by 8-10 %,...)
(‎Created claim: summary (P836): The function of the economiser is to recover the existing heat in the discharge fumes by heating the water that comes from the mother tank approximately from 90 °C to 110 °C, and from the same to charge to the boiler. Currently this water is heated with one of the existing gas boilers; therefore, such consumption will no longer be necessary with the new installation. _x000D_ the project will allow to increase the steady performance by 8-10 %, th...)
Property / summary
 
The function of the economiser is to recover the existing heat in the discharge fumes by heating the water that comes from the mother tank approximately from 90 °C to 110 °C, and from the same to charge to the boiler. Currently this water is heated with one of the existing gas boilers; therefore, such consumption will no longer be necessary with the new installation. _x000D_ the project will allow to increase the steady performance by 8-10 %, thus reducing the distance between the energy delivered to the silo and the demand in the manufacturing process, being undoubtedly a step forward in reducing the ppm in smoke suspension, reducing operating costs and maximising overall efficiency; for every 10 °C decrease in exhaust gas temperature, the degree of efficiency is increased by 1 %. (English)
Property / summary: The function of the economiser is to recover the existing heat in the discharge fumes by heating the water that comes from the mother tank approximately from 90 °C to 110 °C, and from the same to charge to the boiler. Currently this water is heated with one of the existing gas boilers; therefore, such consumption will no longer be necessary with the new installation. _x000D_ the project will allow to increase the steady performance by 8-10 %, thus reducing the distance between the energy delivered to the silo and the demand in the manufacturing process, being undoubtedly a step forward in reducing the ppm in smoke suspension, reducing operating costs and maximising overall efficiency; for every 10 °C decrease in exhaust gas temperature, the degree of efficiency is increased by 1 %. (English) / rank
 
Normal rank
Property / summary: The function of the economiser is to recover the existing heat in the discharge fumes by heating the water that comes from the mother tank approximately from 90 °C to 110 °C, and from the same to charge to the boiler. Currently this water is heated with one of the existing gas boilers; therefore, such consumption will no longer be necessary with the new installation. _x000D_ the project will allow to increase the steady performance by 8-10 %, thus reducing the distance between the energy delivered to the silo and the demand in the manufacturing process, being undoubtedly a step forward in reducing the ppm in smoke suspension, reducing operating costs and maximising overall efficiency; for every 10 °C decrease in exhaust gas temperature, the degree of efficiency is increased by 1 %. (English) / qualifier
 
point in time: 12 October 2021
Timestamp+2021-10-12T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0

Revision as of 17:02, 12 October 2021

Project Q3163058 in Spain
Language Label Description Also known as
English
Boiler economiser
Project Q3163058 in Spain

    Statements

    0 references
    5,394,511.5 Euro
    0 references
    10,789,023.0 Euro
    0 references
    50.0 percent
    0 references
    27 July 2018
    0 references
    11 April 2021
    0 references
    LIVEN, S.A.
    0 references
    0 references

    42°6'4.14"N, 1°50'43.73"E
    0 references
    08022
    0 references
    La función del economizador consiste en recuperar el calor existente en los humos de descarga calentando el agua que procede del tanque nodriza aproximadamente desde 90ºC hasta 110ºC, y desde el mismo cargar a la caldera. Actualmente dicha agua se calienta con una de las calderas de gas existentes; por lo que dicho consumo dejará de ser necesario con la nueva instalación. _x000D_ El proyecto permitirá aumentar un 8-10% el rendimiento estacionario, consiguiendo reducir la distancia entre la energía entregada al silo y la demanda en el proceso de fabricación, siendo sin duda un paso adelante en la disminución de los ppm en suspensión de los humos, reducción de costes operativos y maximización de la eficiencia global; por cada 10ºC de disminución de la temperatura de los gases de escape, se incrementa el grado de eficiencia en un 1%. (Spanish)
    0 references
    The function of the economiser is to recover the existing heat in the discharge fumes by heating the water that comes from the mother tank approximately from 90 °C to 110 °C, and from the same to charge to the boiler. Currently this water is heated with one of the existing gas boilers; therefore, such consumption will no longer be necessary with the new installation. _x000D_ the project will allow to increase the steady performance by 8-10 %, thus reducing the distance between the energy delivered to the silo and the demand in the manufacturing process, being undoubtedly a step forward in reducing the ppm in smoke suspension, reducing operating costs and maximising overall efficiency; for every 10 °C decrease in exhaust gas temperature, the degree of efficiency is increased by 1 %. (English)
    12 October 2021
    0 references
    Berga
    0 references

    Identifiers

    FN17IND02414
    0 references