(10360.14072017.115000022) PRIMARY SCHOOL IN THE CAPITAL CITY (Q2155708): Difference between revisions
Jump to navigation
Jump to search
(Removed claim: financed by (P890): Directorate-General for Regional and Urban Policy (Q8361), Removing unnecessary financed by statement) |
(Changed label, description and/or aliases in fr, and other parts: Adding French translations) |
||||||||||||||
label / fr | label / fr | ||||||||||||||
(10360.14072017.115000022) ÉCOLE PRIMAIRE CAPITALE DE CAVRIGLIA | |||||||||||||||
Property / summary | |||||||||||||||
TRANSFORMATION DU BÂTIMENT EXISTANT EN UN BÂTIMENT À ÉNERGIE QUASI NULLE (NZEB) DONC? COMME PRÉVU À L’ANNEXE 1 DE L’ARRÊTÉ MINISTÉRIEL DU 26 JUIN 2015?EXIGENCES MINIMALES?. EN DÉTAIL, ALLEZ-VOUS Y ALLER? POUR EFFECTUER:- L’ISOLATION DES PAROIS DU PÉRIMÈTRE PAR L’INSTALLATION D’UNE COUCHE EXTÉRIEURE EN EPS (?=0,034 W/MK,?=40 KG/M3), D’UNE ÉPAISSEUR DE 16 CM;- L’ISOLATION DES TOITURES DES BÂTIMENTS À L’AIDE DE MATÉRIAUX ISOLANTS TELS QUE GARANTIR DES TRANSMISSIONS THERMIQUES ÉGALES OU INFÉRIEURES À 0,20 W/MQK.- INSTALLATION D’UN SYSTÈME D’AUTOMATISATION DU BÂTIMENT AVEC CHRONOTHERMOSTAT ET VANNES THERMOSTATIQUES SANS FIL SUR CHAQUE CORPS CHAUFFANT AVEC DES POSSIBILITÉS? GESTION À DISTANCE DES SYSTÈMES CONFORMÉMENT AU PARAGRAPHE 5.7.2 DES RÈGLES RELATIVES À L’APPLICATION DU COMPTE THERMIQUE 2.0;- REMPLACEMENT DES SURFACES VITRÉES ACTUELLES PAR DES CADRES DE FENÊTRE PAR UN CADRE EN PVC À 5 CHAMBRES ET DOUBLE VITRAGE 4+ 4/15/3/15/3+ 3 PAR DOUBLE TRAITEMENT FAIBLEMENT ÉMISSIF REMPLI DE GAZ D’ARGON;- REMPLACEMENT DU COURANT G (French) | |||||||||||||||
Property / summary: TRANSFORMATION DU BÂTIMENT EXISTANT EN UN BÂTIMENT À ÉNERGIE QUASI NULLE (NZEB) DONC? COMME PRÉVU À L’ANNEXE 1 DE L’ARRÊTÉ MINISTÉRIEL DU 26 JUIN 2015?EXIGENCES MINIMALES?. EN DÉTAIL, ALLEZ-VOUS Y ALLER? POUR EFFECTUER:- L’ISOLATION DES PAROIS DU PÉRIMÈTRE PAR L’INSTALLATION D’UNE COUCHE EXTÉRIEURE EN EPS (?=0,034 W/MK,?=40 KG/M3), D’UNE ÉPAISSEUR DE 16 CM;- L’ISOLATION DES TOITURES DES BÂTIMENTS À L’AIDE DE MATÉRIAUX ISOLANTS TELS QUE GARANTIR DES TRANSMISSIONS THERMIQUES ÉGALES OU INFÉRIEURES À 0,20 W/MQK.- INSTALLATION D’UN SYSTÈME D’AUTOMATISATION DU BÂTIMENT AVEC CHRONOTHERMOSTAT ET VANNES THERMOSTATIQUES SANS FIL SUR CHAQUE CORPS CHAUFFANT AVEC DES POSSIBILITÉS? GESTION À DISTANCE DES SYSTÈMES CONFORMÉMENT AU PARAGRAPHE 5.7.2 DES RÈGLES RELATIVES À L’APPLICATION DU COMPTE THERMIQUE 2.0;- REMPLACEMENT DES SURFACES VITRÉES ACTUELLES PAR DES CADRES DE FENÊTRE PAR UN CADRE EN PVC À 5 CHAMBRES ET DOUBLE VITRAGE 4+ 4/15/3/15/3+ 3 PAR DOUBLE TRAITEMENT FAIBLEMENT ÉMISSIF REMPLI DE GAZ D’ARGON;- REMPLACEMENT DU COURANT G (French) / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / summary: TRANSFORMATION DU BÂTIMENT EXISTANT EN UN BÂTIMENT À ÉNERGIE QUASI NULLE (NZEB) DONC? COMME PRÉVU À L’ANNEXE 1 DE L’ARRÊTÉ MINISTÉRIEL DU 26 JUIN 2015?EXIGENCES MINIMALES?. EN DÉTAIL, ALLEZ-VOUS Y ALLER? POUR EFFECTUER:- L’ISOLATION DES PAROIS DU PÉRIMÈTRE PAR L’INSTALLATION D’UNE COUCHE EXTÉRIEURE EN EPS (?=0,034 W/MK,?=40 KG/M3), D’UNE ÉPAISSEUR DE 16 CM;- L’ISOLATION DES TOITURES DES BÂTIMENTS À L’AIDE DE MATÉRIAUX ISOLANTS TELS QUE GARANTIR DES TRANSMISSIONS THERMIQUES ÉGALES OU INFÉRIEURES À 0,20 W/MQK.- INSTALLATION D’UN SYSTÈME D’AUTOMATISATION DU BÂTIMENT AVEC CHRONOTHERMOSTAT ET VANNES THERMOSTATIQUES SANS FIL SUR CHAQUE CORPS CHAUFFANT AVEC DES POSSIBILITÉS? GESTION À DISTANCE DES SYSTÈMES CONFORMÉMENT AU PARAGRAPHE 5.7.2 DES RÈGLES RELATIVES À L’APPLICATION DU COMPTE THERMIQUE 2.0;- REMPLACEMENT DES SURFACES VITRÉES ACTUELLES PAR DES CADRES DE FENÊTRE PAR UN CADRE EN PVC À 5 CHAMBRES ET DOUBLE VITRAGE 4+ 4/15/3/15/3+ 3 PAR DOUBLE TRAITEMENT FAIBLEMENT ÉMISSIF REMPLI DE GAZ D’ARGON;- REMPLACEMENT DU COURANT G (French) / qualifier | |||||||||||||||
point in time: 23 December 2021
|
Revision as of 08:05, 23 December 2021
Project Q2155708 in Italy
Language | Label | Description | Also known as |
---|---|---|---|
English | (10360.14072017.115000022) PRIMARY SCHOOL IN THE CAPITAL CITY |
Project Q2155708 in Italy |
Statements
146,529.7 Euro
0 references
598,080.37 Euro
0 references
24.5 percent
0 references
3 April 2018
0 references
3 April 2020
0 references
16 November 2020
0 references
COMUNE DI CAVRIGLIA
0 references
TRASFORMAZIONE DELL?EDIFICIO ESISTENTE IN EDIFICIO AD ENERGIA QUASI ZERO (NZEB) COS? COME PREVISTO ALL?ALLEGATO 1 DEL D.M. 26 GIUGNO 2015 ?REQUISITI MINIMI?. NEL DETTAGLIO SI ANDR? AD ESEGUIRE:- COIBENTAZIONE DELLE PARETI PERIMETRALI ATTRAVERSO L?INSTALLAZIONE DI UN CAPPOTTO ESTERNO IN EPS (?=0,034 W/MK, ?=40 KG/M3), DALLO SPESSORE DI 16 CM;- COIBENTAZIONE DELLA COPERTURE DEGLI EDIFICI MEDIANTE USO DI MATERIALI ISOLANTI TALI DA GARANTIRE TRASMITTANZE TERMICHE PARI O INFERIORI A 0,20 W/MQK.- INSTALLAZIONE DI UN SISTEMA DI BUILDING AUTOMATION CON CRONOTERMOSTATO E VALVOLE TERMOSTATICHE WIRELESS SU OGNI CORPO SCALDANTE CON POSSIBILIT? DI TELEGESTIONE DEGLI IMPIANTI DA REMOTO CONFORMEMENTE A QUANTO PREVISTO AL PAR. 5.7.2 DELLE REGOLE APPLICATIVE DEL CONTO TERMICO 2.0;- SOSTITUZIONE DELLE ATTUALI SUPERFICI VETRATE CON SERRAMENTI AVENTI TELAIO IN PVC A 5 CAMERE CAVE E DOPPIA VETROCAMERA 4+4/15/3/15/3+3 CON DOPPIO TRATTAMENTO BASSO EMISSIVO RIEMPITA IN GAS ARGON;- SOSTITUZIONE DEGLI ATTUALI G (Italian)
0 references
CONVERSION OF THE EXISTING BUILDING INTO NZEBS (NZEBS)? AS PROVIDED FOR IN ANNEX 1 TO THE MINISTERIAL DECREE OF 26 JUNE 2015? IN DETAIL, IS ANDR? DO YOU HAVE EXTERNAL WALLS IN EPS (? = 0,034 W/MK,? = 40 KG/M3), 16 CM THICK; — INSULATION OF THE PERIMETER WALLS IN EPS (? = W/MK,? = KG/M), CM IN THICKNESS; — INSULATION OF THE INSULATION OF THE BUILDING COVER BY THE USE OF INSULATING MATERIALS TO ENSURE A THERMAL TRANSMITTANCE OF 0,20 W/MQKD — INSTALLATION OF A SYSTEM OF BUILDING AUTOMATION WITH CHRONOTHERMOSTAT AND A SYSTEM OF “BUILDING AUTOMATION WITH CHRONIC-THERMOSTAT” AND “WIRELESS THERMOSTATIC VALVES” OVER EACH BODY WHICH IS READY TO DO SO? REMOTE MANAGEMENT OF REMOTE MANAGEMENT IN ACCORDANCE WITH PARAGRAPH 5.7.2 OF THE IMPLEMENTING RULES FOR THE THERMAL ACCOUNT 2.0; — REPLACEMENT OF THE CURRENT GLASS SURFACES WITH FRAMES WITH PVC FRAMES TO 5 HOLLOW AND DOUBLE WINDOWS 4 + 4/15/3/15/3 + 3 WITH DOUBLE EMISSION TREATMENT FILLED WITH ARGON; (English)
0 references
TRANSFORMATION DU BÂTIMENT EXISTANT EN UN BÂTIMENT À ÉNERGIE QUASI NULLE (NZEB) DONC? COMME PRÉVU À L’ANNEXE 1 DE L’ARRÊTÉ MINISTÉRIEL DU 26 JUIN 2015?EXIGENCES MINIMALES?. EN DÉTAIL, ALLEZ-VOUS Y ALLER? POUR EFFECTUER:- L’ISOLATION DES PAROIS DU PÉRIMÈTRE PAR L’INSTALLATION D’UNE COUCHE EXTÉRIEURE EN EPS (?=0,034 W/MK,?=40 KG/M3), D’UNE ÉPAISSEUR DE 16 CM;- L’ISOLATION DES TOITURES DES BÂTIMENTS À L’AIDE DE MATÉRIAUX ISOLANTS TELS QUE GARANTIR DES TRANSMISSIONS THERMIQUES ÉGALES OU INFÉRIEURES À 0,20 W/MQK.- INSTALLATION D’UN SYSTÈME D’AUTOMATISATION DU BÂTIMENT AVEC CHRONOTHERMOSTAT ET VANNES THERMOSTATIQUES SANS FIL SUR CHAQUE CORPS CHAUFFANT AVEC DES POSSIBILITÉS? GESTION À DISTANCE DES SYSTÈMES CONFORMÉMENT AU PARAGRAPHE 5.7.2 DES RÈGLES RELATIVES À L’APPLICATION DU COMPTE THERMIQUE 2.0;- REMPLACEMENT DES SURFACES VITRÉES ACTUELLES PAR DES CADRES DE FENÊTRE PAR UN CADRE EN PVC À 5 CHAMBRES ET DOUBLE VITRAGE 4+ 4/15/3/15/3+ 3 PAR DOUBLE TRAITEMENT FAIBLEMENT ÉMISSIF REMPLI DE GAZ D’ARGON;- REMPLACEMENT DU COURANT G (French)
23 December 2021
0 references
Identifiers
G38G17000040003
0 references