Applied development of LG/LP type VVN insulators with high short-circuit resistance up to 63 kA (Q11200): Difference between revisions
Jump to navigation
Jump to search
(Removed claim: summary (P836): The project shall address research into the technological options for the production of bar insulators of the VVN type LG/LP type according to IEC 60 383, including the determination of the appropriate design of a complete hinge and protective fittings with a short-circuit resistance of up to 63 kA in the case of the IEC 61 467 short-circuit test and subsequent implementation in grid networks in the EU. The project output will be operational p...) |
(Created claim: summary (P836): The project deals with research of technological possibilities of production of HVN bar insulators of LG/LP type according to IEC 60 383 incl. determination of suitable construction of the whole hinge and protective valves with short circuit resistance up to 63 kA during short-circuit test according to IEC 61 467 and subsequent implementation in distribution networks in the EU. The output of the project will be functional prototypes. It will be...) |
||||||||||||||
Property / summary | |||||||||||||||
The project deals with research of technological possibilities of production of HVN bar insulators of LG/LP type according to IEC 60 383 incl. determination of suitable construction of the whole hinge and protective valves with short circuit resistance up to 63 kA during short-circuit test according to IEC 61 467 and subsequent implementation in distribution networks in the EU. The output of the project will be functional prototypes. It will be verified whether ceramic materials according to IEC 673 C120/C130 are able to withstand the thermal effect of a plasma discharge with a current of 63kA while maintaining moss. properties. a. (English) | |||||||||||||||
Property / summary: The project deals with research of technological possibilities of production of HVN bar insulators of LG/LP type according to IEC 60 383 incl. determination of suitable construction of the whole hinge and protective valves with short circuit resistance up to 63 kA during short-circuit test according to IEC 61 467 and subsequent implementation in distribution networks in the EU. The output of the project will be functional prototypes. It will be verified whether ceramic materials according to IEC 673 C120/C130 are able to withstand the thermal effect of a plasma discharge with a current of 63kA while maintaining moss. properties. a. (English) / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / summary: The project deals with research of technological possibilities of production of HVN bar insulators of LG/LP type according to IEC 60 383 incl. determination of suitable construction of the whole hinge and protective valves with short circuit resistance up to 63 kA during short-circuit test according to IEC 61 467 and subsequent implementation in distribution networks in the EU. The output of the project will be functional prototypes. It will be verified whether ceramic materials according to IEC 673 C120/C130 are able to withstand the thermal effect of a plasma discharge with a current of 63kA while maintaining moss. properties. a. (English) / qualifier | |||||||||||||||
point in time: 22 October 2020
|
Revision as of 15:41, 22 October 2020
Project in Czech Republic financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | Applied development of LG/LP type VVN insulators with high short-circuit resistance up to 63 kA |
Project in Czech Republic financed by DG Regio |
Statements
2,956,378.96 Czech koruna
0 references
8,040,193.0 Czech koruna
0 references
36.77 percent
0 references
26 April 2017
0 references
30 June 2019
0 references
Elektroporcelán a.s.
0 references
44001
0 references
Projekt řeší výzkum technologických možností výroby tyčových izolátorů VVN typu LG/LP dle IEC 60 383 vč. stanovení vhodné konstrukce celého závěsu a ochranných armatur se zkratovou odolností až 63 kA při zkratové zkoušce dle IEC 61 467 a následnou implementaci v rozvodných sítích v EU. Výstupem projektu budou funkční prototypy. Dojde k ověření, zda keramické materiály dle IEC 673 C120/C130 jsou schopny odolat tepelnému vlivu plazmatického výboje s proudem 63kA při zachování mech. vlastností. a. (Czech)
0 references
The project deals with research of technological possibilities of production of HVN bar insulators of LG/LP type according to IEC 60 383 incl. determination of suitable construction of the whole hinge and protective valves with short circuit resistance up to 63 kA during short-circuit test according to IEC 61 467 and subsequent implementation in distribution networks in the EU. The output of the project will be functional prototypes. It will be verified whether ceramic materials according to IEC 673 C120/C130 are able to withstand the thermal effect of a plasma discharge with a current of 63kA while maintaining moss. properties. a. (English)
22 October 2020
0 references
Identifiers
CZ.01.1.02/0.0/0.0/16_083/0010075
0 references