Construction of the EC Gas cogeneration system (Q84912): Difference between revisions
Jump to navigation
Jump to search
(Removed claim: EU contribution (P835): 1,347,157.5647999998 euro) |
(Changed an Item: Fixing rounding issue) |
||||||||||||||
Property / EU contribution | |||||||||||||||
1,347,157.56 Euro
| |||||||||||||||
Property / EU contribution: 1,347,157.56 Euro / rank | |||||||||||||||
Preferred rank | |||||||||||||||
Property / EU contribution: 1,347,157.56 Euro / qualifier | |||||||||||||||
exchange rate to Euro: 0.24 Euro
| |||||||||||||||
Property / EU contribution: 1,347,157.56 Euro / qualifier | |||||||||||||||
point in time: 13 January 2020
|
Revision as of 07:13, 23 September 2020
Project in Poland financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | Construction of the EC Gas cogeneration system |
Project in Poland financed by DG Regio |
Statements
5,613,156.52 zloty
0 references
19,322,397.67 zloty
0 references
29.05 percent
0 references
1 November 2018
0 references
31 December 2020
0 references
PGNIG TERMIKA SPÓŁKA AKCYJNA
0 references
Nadrzędnym celem projektu jest zwiększenie efektywności wytwarzania en. elekt. i cieplnej co przełoży się na ogr. emisji do środowiska, w tym w szczególności emisji CO2. Ilość unikniętej emisji CO2 w wyniku realizacji projektu wynosi 31 927t/rok. Ilość CO2 emitowana rocznie przed projektem wynosi 47 976t/rok. Stąd obliczono, iż w wyn. realiz. proj. nastąpi redukcja emisji CO2 o 67%(wartość wyższa niż 30%). Metodologię obliczenia zamieszczono w zał. nr 4 i 9. Obecnie część M. Przemyśl zaopatrywana jest w en. cieplną wytwarzaną w ciepłowni węglowej, w wyniku realizacji projektu, obok ograniczenia emisji, osiągnięte zostanie ograniczenie wykorzystania paliw stałych (węgiel kamienny). Projekt wpisuje się w technologię wysokosprawnej kogeneracji. Współczynnik oszczędności energii pierwotnej (PES) spełnia kryterium określone w Załączniku II do Dyr. 2012/27/UE i wynosi 23,56% (Dyr. zakłada, iż wartość PES > 10%). Współczynnik wyliczono zgodnie z Dz.U.2014 poz. 1940 w zał. dod. nr2 (metologia). Zakres planowanych działań obejmuje zabudowę i uruchomienie elektrociepłowni gazowej na terenie sąsiadującym z Ciepłownią Zasanie należącą MPEC Przemyśl, zlokalizowanej przy ul. Emilii Plater 8, składającej się z układ dwóch gazowych agregatów kogeneracyjnych o mocy cieplnej ok. 4,5 MWt i mocy elektrycznej ok. 4,7 MWe, oraz dwóch konwencjonalnych kotłów wodnych o mocy 5 i 0,2 MWt. Zakładaną sprawność wytwarzania energii określono na poziomie 83,9%. Dodatkowo wybudowana zostanie sieć gazowa dostarczająca gaz do elektrociepłowni. Planowane do uruchomienia źródło przyczyni się do obniżenia zanieczyszczenia powietrza atmosferycznego w mieście poprzez całkowite wyeliminowanie w okresie letnim i częściowemu w zimie produkcji prowadzonej obecnie w lokalnej kotłowni węglowej. Projektowane źródło będzie zasilane gazem ziemnym wysokometanowym, zaś wytwarzane ciepło będzie sprzedawane do MPEC w oparciu o zapisy wieloletniej umowy sprzedaży ciepła. Z kolei wytworzona w układzie energia elektrycz (Polish)
0 references
The overall objective of the project is to increase the efficiency of the generation of electricity and electricity, which will translate into a tail in emissions into the environment, including in particular CO2 emissions.The amount of CO2 avoided as a result of the project is 31 927 t/year.The amount of CO2 emitted annually before the project is 47 976 t/year.Thus, a reduction in CO2 emissions of 67 % (higher than 30 %) will be achieved.The methodology for the calculation is set out in Annexes 4 and 9.Today, part of the M. Przemyśl is supplied to heat produced in the coal heating plant, as a result of project implementation, in addition to the reduction in emissions, a reduction in the use of solid fuels (coal) will be achieved.The project is in line with high efficiency cogeneration technology.The primary energy saving factor (PES) complies with the criterion set out in Annex II to Dir.2012/27/EU and stands at 23.56 % (Dir. it assumes that PES value > 10 %).The coefficient was calculated in accordance with the Journal of Laws 2014, item1940 in Annex No 2 (metology).The scope of the activities envisaged includes the construction and operation of a gas-fired power plant in a neighbouring area with the benefit of the MPEC Przemyśl, located at ul.Emilia Plast 8, consisting of a system of two gas-fired cogeneration units with thermal input.4,5 MWt and electric power ca.4,7 MWe and two conventional water boilers with a power of 5 and 0,2 MWt.The expected energy generation efficiency is set at 83.9 %.In addition, a gas network will be built to supply gas to CHP plants.The source will contribute to the reduction of atmospheric pollution in the city by completely eliminating the current production in the local coal boiler in summer and part in winter.The intended source will be powered by natural gas with methane-rich natural gas and the heat produced will be sold into the MPEC based on the provisions of the multi-annual contract of heat sales.On the other hand, the electricity generated by the electricity system (English)
0 references
Identifiers
POIS.01.06.01-00-0041/18
0 references