DEVELOPMENT OF THE PHOTOVOLTAIC SYSTEM OF THE REHABILITATION HOSPITAL AND CLINIC IN NAGYKŐRÖS (Q3943864): Difference between revisions
Jump to navigation
Jump to search
(Removed claims) |
(Changed an Item: fix budget) |
||||||||||||||
Property / co-financing rate | |||||||||||||||
89.0 percent
| |||||||||||||||
Property / co-financing rate: 89.0 percent / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / budget | |||||||||||||||
118,092,975.0 forint
| |||||||||||||||
Property / budget: 118,092,975.0 forint / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / budget | |||||||||||||||
333,848.84 Euro
| |||||||||||||||
Property / budget: 333,848.84 Euro / rank | |||||||||||||||
Preferred rank | |||||||||||||||
Property / budget: 333,848.84 Euro / qualifier | |||||||||||||||
exchange rate to Euro: 0.002827 Euro
| |||||||||||||||
Property / budget: 333,848.84 Euro / qualifier | |||||||||||||||
point in time: 15 February 2022
| |||||||||||||||
Property / EU contribution | |||||||||||||||
105,102,747.75 forint
| |||||||||||||||
Property / EU contribution: 105,102,747.75 forint / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / EU contribution | |||||||||||||||
297,125.47 Euro
| |||||||||||||||
Property / EU contribution: 297,125.47 Euro / rank | |||||||||||||||
Preferred rank | |||||||||||||||
Property / EU contribution: 297,125.47 Euro / qualifier | |||||||||||||||
exchange rate to Euro: 0.002827 Euro
| |||||||||||||||
Property / EU contribution: 297,125.47 Euro / qualifier | |||||||||||||||
point in time: 15 February 2022
|
Revision as of 02:10, 15 February 2022
Project Q3943864 in Hungary
Language | Label | Description | Also known as |
---|---|---|---|
English | DEVELOPMENT OF THE PHOTOVOLTAIC SYSTEM OF THE REHABILITATION HOSPITAL AND CLINIC IN NAGYKŐRÖS |
Project Q3943864 in Hungary |
Statements
105,102,747.75 forint
0 references
118,092,975.0 forint
0 references
89.0 percent
0 references
21 July 2017
0 references
3 July 2018
0 references
Nagykorösi Rehabilitációs Szakkórház és Rendelointézet
0 references
Az energiatermelést biztosító napelemek a Kórház Fáskert utcai és a belvárosi Széchenyi téri telephelyén kerülnek kialakításra az alábbi részletek szerint: Összesen: 194,94 kWp beépített csúcsteljesítményű napelem modul, 175 kVA AC teljesítményű inverter. Keleti szárny: 214 db napelem panel 3 db 17,5KVA-es inverter. Nyugati szárny: 156 db napelem panel 1 db 17,5-es és 1 db 20KVA-es inverter Konyha: 104db. napelem panel. 2 db 12,5KVA-es inverter Kazánház: 52db. napelem panel. 1 db 12,5KVA-es inverter Patológia: 40db napelem panel. 1db 10KVA-es inverter Belvárosi rendelőintézet: 156db napelem panel. 1db 20-as és 1 db 17,5KVA-es inverter. A napelemek 270W átlagos teljesítményű, polikristályos típusú, alumínium kerettel ellátott panelek. 18-23 db, MC-4 típusú csatlakozóval sorba kötött napelem alkot egy-egy „string”-et, amelyek UV álló 4 mm2 keresztmetszetű, tartószerkezeten elhelyezett solar kábeleken keresztül csatlakoznak a PV-DC-x jelű szekrényekbe, majd az inverterekbe. Az inverterek a napelemek által létrehozott DC feszültséget 3 fázisú AC feszültséggé alakítja (3f 400V 50Hz). 270W átlagos teljesítménnyel számolva 722 db panelt használunk, így összesen 194,94 kWp beépített teljesítményt tervezünk. Az inverterek a tetőn lévő felépítmények, padlásterek, gépház oldalfalán kerülnek elhelyezésre. A panelekről érkező solar DC-kábelek PV-DC-x jelű túlfeszültségdobozokba futnak be, ahol a rendszer 1+2. típusú DC túlfeszültség-levezető eszközei találhatóak. A PV-DC-x szekrények az inverter mellett kapnak helyet. A PV-DC szekrényeket és az invertereket solar kábelekkel kötjük össze. Az inverterek által termelt energia 5x6 mm2 keresztmetszetű, NYY-J típus kábeleken keresztül PV-AC-y jelű gyűjtőszekrényekbe jut, ahol az inverterek túlfeszültség-védelmi és túláramvédelmi készülékei, valamint egy távvezérelhető leválasztó kapcsoló található. A PV-AC-y szekrények 5-eres erőátviteli kábellel lesznek összekötve az adott épület alelosztó berendezésével, ahol a napelemes rendszer túláramvédelmi készüléke kerül elhelyezésre. A napelemek által termelt energiát az létesítmény meglévő villamos hálózatán keresztül a létesítmény fogyasztói használják fel. A napelemes rendszer kórház telephelyén nem termelhet vissza a közcélú hálózatba, ezért a létesítmény 0,4 kV-os főelosztó berendezésébe visszatáplálás mentesítő rendszer beépítése szükséges, amely lekapcsolja vagy leszabályozza a napelemes rendszert, mielőtt a létesítményből energia kitáplálás történne. A belvárosi rendelőintézet telephelyén 50KVA teljesítmény alatti ún. HMKE kerül kialakítása az áramszolgáltatói elszámolás AD-VESZ mérős kialakítással, szaldó számítással történik. A napelemek elhelyezése miatt a meglévő villámvédelmi rendszert módosítani kell a vonatkozó előírások szerint. (Hungarian)
0 references
Solar panels for energy production will be installed at the Fáskert Street and downtown Széchenyi Square premises of the Hospital according to the following details: Total: 194,94 kWp built-in solar panel module, 175 kVA AC power inverter. East wing: 214 pcs solar panel 3 pcs 17.5KVA inverters. West wing: 156 pcs solar panel 1 pcs 17.5 and 1 inverter 20KVA Kitchen: 104pcs. solar panel. 2 12,5KVA inverter boiler house: 52pcs. solar panel. 1 pcs 12.5KVA inverter pathology: 40pcs solar panel. 1pc 10KVA inverter downtown: 156pcs solar panel. 1 pcs 20 and 1 17.5KVA inverter. Solar panels are panels with an average power of 270 W, polycrystalline type with aluminium frame. 18-23 solar panels in series with MC-4 connectors form a “string” that connects to the PV-DC-x cabinets and then to the inverters via UV standing 4 mm² solar cables placed on a support structure. The inverters convert the DC voltage generated by solar panels into 3 phase AC voltage (3f 400V 50 Hz). With an average power of 270 W, we use 722 panels, so a total of 194,94 kWp of built-in power is planned. The inverters are placed on the side walls of the rooftops, lofts, engine rooms. Solar DC cables from the panels run into PV-DC-x overvoltage boxes, where the system’s type 1+ 2 DC surge arrester devices are located. The PV-DC-x cabinets are located next to the inverter. PV-DC cabinets and inverters are connected with solar cables. The energy generated by the inverters is delivered through 5x6 mm² cross-section NYY-J cables into collection cabinets marked PV-AC-y, where the inverters’ overvoltage protection and overcurrent protection devices and a remotely controlled isolation switch are located. The PV-AC-y cabinets will be connected by a 5-meter power cable to the casing of the building, where the solar system overcurrent protection device is located. The energy generated by solar panels is used by the customers of the installation through the existing electricity network of the installation. The solar system cannot be regenerated to the public network at the hospital site, therefore it is necessary to install a regenerative system in the installation’s main distribution system of 0.4 kV to disconnect or deactivate the solar system before energy is released from the installation. On the premises of the institute in the city centre, the so-called HMKE under 50KVA performance will be set up by the electricity service provider with AD-VESZ meter design and calculation. Due to the installation of solar panels, the existing lightning protection system should be modified in accordance with the relevant requirements. (English)
9 February 2022
0 references
Des panneaux solaires pour la production d’énergie seront installés sur la rue Fáskert et dans les locaux de la place Széchenyi du centre-ville de l’hôpital selon les détails suivants: Total: Module de panneau solaire intégré de 194,94 kWp, onduleur d’alimentation CA de 175 kVA. Aile Est: 214 pcs panneau solaire 3 pcs 17,5KVA onduleurs. Aile ouest: 156 pcs panneau solaire 1 PCs 17,5 et 1 onduleur 20KVA Cuisine: 104pcs. panneau solaire. 2 12,5KVA chaufferie d’onduleur: 52pcs. panneau solaire. 1 pcs 12,5KVA pathologie de l’onduleur: Panneau solaire 40pcs. Onduleur 1pc 10KVA centre-ville: 156pcs panneau solaire. 1 pcs 20 et 1 17,5KVA onduleur. Les panneaux solaires sont des panneaux d’une puissance moyenne de 270 W, de type polycristallin avec cadre en aluminium. 18-23 panneaux solaires en série avec connecteurs MC-4 forment une «chaîne» qui se connecte aux armoires PV-DC-x, puis aux onduleurs via des câbles solaires UV de 4 mm² placés sur une structure de support. Les onduleurs convertissent la tension CC générée par les panneaux solaires en tension AC 3 phases (3f 400V 50 Hz). Avec une puissance moyenne de 270 W, nous utilisons 722 panneaux, donc un total de 194,94 kWp de puissance intégrée est prévu. Les onduleurs sont placés sur les parois latérales des toits, lofts, salles des machines. Les câbles à courant continu solaire des panneaux s’écoulent dans des boîtes de surtension PV-DC-x, où se trouvent les dispositifs de surtension de type 1+ 2 DC du système. Les armoires PV-DC-x sont situées à côté de l’onduleur. Les armoires et onduleurs PV-DC sont connectés avec des câbles solaires. L’énergie générée par les onduleurs est fournie par des câbles NYY-J de 5x6 mm² dans des armoires de collecte marquées PV-AC-y, où se trouvent les dispositifs de protection contre les surtensions et les surintensités ainsi qu’un interrupteur d’isolement télécommandé. Les armoires PV-AC-y seront reliées par un câble d’alimentation de 5 mètres au boîtier du bâtiment, où se trouve le dispositif de protection contre les surintensités du système solaire. L’énergie produite par les panneaux solaires est utilisée par les clients de l’installation via le réseau électrique existant de l’installation. Le système solaire ne pouvant être régénéré au réseau public sur le site de l’hôpital, il est donc nécessaire d’installer un système de régénération dans le réseau de distribution principal de l’installation de 0,4 kV pour déconnecter ou désactiver le système solaire avant que l’énergie ne soit libérée de l’installation. Dans les locaux de l’institut du centre-ville, les performances dites HMKE inférieures à 50KVA seront mises en place par le fournisseur d’électricité avec la conception et le calcul des compteurs AD-Vesz. En raison de l’installation de panneaux solaires, le système de protection contre la foudre existant devrait être modifié conformément aux exigences applicables. (French)
10 February 2022
0 references
Nagykőrös, Pest
0 references
Identifiers
KEHOP-5.2.11-16-2017-00107
0 references