Solar system connected to the network at the plant building of Balmaz Sütöde Kft. (Q3933624): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Changed an Item: Adding French translations)
(‎Removed claims)
Property / co-financing rate
55.0 percent
Amount55.0 percent
Unitpercent
 
Property / co-financing rate: 55.0 percent / rank
Normal rank
 
Property / EU contribution
14,437,020 forint
Amount14,437,020 forint
Unitforint
 
Property / EU contribution: 14,437,020 forint / rank
Normal rank
 
Property / EU contribution
39,921.39 Euro
Amount39,921.39 Euro
UnitEuro
 
Property / EU contribution: 39,921.39 Euro / rank
Preferred rank
 
Property / EU contribution: 39,921.39 Euro / qualifier
exchange rate to Euro: 0.00276521 Euro
Amount0.00276521 Euro
UnitEuro
 
Property / EU contribution: 39,921.39 Euro / qualifier
point in time: 3 December 2021
Timestamp+2021-12-03T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0
 
Property / budget
71,755.286 Euro
Amount71,755.286 Euro
UnitEuro
 
Property / budget: 71,755.286 Euro / rank
Preferred rank
 
Property / budget: 71,755.286 Euro / qualifier
exchange rate to Euro: 0.0027336256 Euro
Amount0.0027336256 Euro
UnitEuro
 
Property / budget: 71,755.286 Euro / qualifier
point in time: 15 December 2021
Timestamp+2021-12-15T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0
 
Property / budget
26,249,127.273 forint
Amount26,249,127.273 forint
Unitforint
 
Property / budget: 26,249,127.273 forint / rank
Normal rank
 

Revision as of 11:00, 13 February 2022

Project Q3933624 in Hungary
Language Label Description Also known as
English
Solar system connected to the network at the plant building of Balmaz Sütöde Kft.
Project Q3933624 in Hungary

    Statements

    0 references
    1 April 2020
    0 references
    31 December 2021
    0 references
    BALMAZ-SÜTŐDE Élelmiszeripari Feldolgozó és Kereskedelmi Korlátolt Felelősségű Társaság
    0 references
    0 references

    47°36'41.87"N, 21°20'37.46"E
    0 references
    A költséges szünetmentes funkció kialakításának indoka, hogy az üzem nagyon modern számítógépes vezérléssel felszerelt gépekkel dolgozik, melyek a rövid áramkimaradásokra is érzékenyek, így ezek a rövid feszültség ingadozások kiküszöbölése az elsődleges célja a szünetmentes funkciónak. A kialakításra kerülő napelemes rendszer a várakozás szerint fedezni fogja a teljes fogyasztás jelentős részét, mintegy 54780 kWh zöld energia megtermelésével, így költséget csökkent, és zöld energia felhasználást biztosítja. Részletes szakmai tartalom: A létesítmény jelenleg meglévő villamos-energia igénye a fogyasztásmérési ponton lehetővé teszi a háztartási méretű kiserőműnél megengedett maximum 50kVA termelői berendezés csatlakozását. A tervezett rendszer AC-oldali teljesítménye: 45 kW A fogyasztásmérőnél elhelyezett főelosztóhoz csatlakozik az inverterek AC kimenetén megjelenő230V hálózati feszültség NYY 4x25mm2 kábellel. A DC kábelek a szendvics panel tető héjazatot az ereszen túl átlépve, a külső falsíkon, fém kábelcsatornába helyezve, függőleges nyomvonalon vezetve, a földszinti belső falfelületen elhelyezett inverterekhez kapcsolódnak. Alkalmazott inverterek: • 4 db Fronius Symo hybrid 5.0 kW • 1 db Fronius Symo 25 kW. Az alkalmazandó inverterek E.ON hálózati területen rendszerengedélyes inverterek. A hybrid inverterek hálózati áramkimaradás esetén szünetmentes áramellátás biztosítására képesek oly módon, hogy 3 db 4,5 kWh teljesítményű Fronius Solar Battery System akkumulátor egység energia menedzsmentjét látják el. A szünetmentes áramellátást a hálózat adott pontjaira kapcsolt termelő berendezések vezérlői, valamint informatikai berendezések kapják abból a célból, hogy a rövid időre bekövetkező áramkimaradások azokat ne károsítsák, illetőleg ne okozzanak újraindítási folyamatokat – következésképpen, gyártás kiesést. A napelemek egyetlen tetősíkon helyezkednek el, szendvicspanel héjazaton, tetősíkkal azonos síkban elhelyezett tartószerkezetre rögzítve. A tartószerkezet szabványos, rozsdamentes kötőelemek és szolár szerelő sínek alkalmazásával rögzíti a napelemeket. Javasolt gyári rendszer: K2 gyártmány. Az inverter DC oldali bemenetére csatlakozik összesen 166 db 300 Wp teljesítményű Canadian Solar HC poly (vágott cellás poli-kristályos) napelem. Ebből 4x20 db napelem a 4 db Fronius Symo 5 kW hybrid inverter, 1x86 db napelem a Fronius Symo 25 kW inverter DC-oldali terhelését biztosítja. A napelemek kapcsolási módját, az egyes stringek bekötését a terv részét képező tervlapok tartalmazzák. A napelemek tetősíkon történő elrendezési rajzát, valamint az inverterek elhelyezését és az AC vezeték főelosztóig vezető nyomvonalát a mellékelt tervlapok tartalmazzák. (Hungarian)
    0 references
    The reason for the costly uninterruptible function is that the plant works with machines equipped with very modern computer controls, which are also sensitive to short power outages, so these short voltage fluctuations are the primary purpose of the uninterrupted function. The solar system to be installed is expected to cover a significant part of the total consumption, producing around 54 780 kWh of green energy, thus reducing costs and ensuring the use of green energy. Detailed professional content: The current electricity demand of the installation at the metering point allows the connection of a maximum of 50kVA production equipment at the household-sized small power plant. AC-side performance of the planned system: 45 kW The main divider at the meter is connected to the AC output of the inverters with a 230V main voltage NYY 4x25 mm² cable. The DC cables are connected to inverters placed on the outer wall plane, placed in a metal duct, along a vertical trail, passing the sandwich panel roof shell beyond the eaves of the wall. Inverters used: • 4 Fronius SYMO hybrid 5.0 kW • 1 Fronius SYMO 25 kW. The inverters to be used in the E.ON network area are system-authorised inverters. Hybrid inverters can provide uninterrupted power in case of power failure by providing energy management of 3 Fronius Solar Battery System battery units with a power output of 4.5 kWh. The uninterrupted power supply is provided to the controllers of the generating equipment connected to the given points of the network, as well as to IT equipment, so that short-term power failures do not damage them or cause restarting processes — consequently, production failures. The solar panels are located on a single roof plane, on a sandwich panel shell, attached to a supporting structure located in the same plane as the roof plane. The support structure fixes the solar panels using standard stainless steel fasteners and solar mounting rails. Recommended factory system: Make K2. The DC side input of the inverter is connected to a total of 166 pcs 300 Wp Canadian Solar HC poly (cut cell poly-crystalline) solar panels. Of these 4x20 solar panels are the 4 Fronius SYMO 5 kW hybrid inverters, 1x86 pcs solar panel provides the DC side load of Fronius SYMO 25 kW inverter. The method of switching solar panels, the connection of the individual strings, is included in the design sheets that form part of the plan. The layout drawings of the solar panels on the roof plane, as well as the positioning of the inverters and the trace of the AC line to the main divider, are set out in the attached design sheets. (English)
    8 February 2022
    0 references
    La raison de la fonction ininterrompue coûteuse est que l’usine fonctionne avec des machines équipées de commandes informatiques très modernes, qui sont également sensibles aux coupures de courant courtes, de sorte que ces fluctuations de courte tension sont l’objectif principal de la fonction ininterrompue. Le système solaire à installer devrait couvrir une part importante de la consommation totale, produisant environ 54 780 kWh d’énergie verte, réduisant ainsi les coûts et assurant l’utilisation de l’énergie verte. Contenu professionnel détaillé: La demande actuelle d’électricité de l’installation au point de mesure permet le raccordement d’un équipement de production de 50 kVA maximum à la petite centrale électrique de taille domestique. Performances côté courant du système prévu: 45 kW Le diviseur principal au compteur est raccordé à la sortie AC des onduleurs avec un câble de tension principale 230V NYY 4x25 mm². Les câbles CC sont reliés à des onduleurs placés sur le plan du mur extérieur, placés dans un conduit métallique, le long d’un sentier vertical, en passant par la coque de toit du panneau sandwich au-delà des avant-toits du mur. Onduleurs utilisés: • 4 Fronius SYMO hybride 5,0 kW • 1 Fronius SYMO 25 kW. Les onduleurs à utiliser dans la zone réseau E.ON sont des onduleurs autorisés par système. Les onduleurs hybrides peuvent fournir une puissance ininterrompue en cas de panne de courant en assurant la gestion de l’énergie de 3 unités de batterie du système de batterie solaire Fronius d’une puissance de 4,5 kWh. L’alimentation électrique ininterrompue est fournie aux contrôleurs de l’équipement de production connecté aux points donnés du réseau, ainsi qu’aux équipements informatiques, de sorte que les pannes de courant à court terme ne les endommagent pas ou ne provoquent pas de redémarrage des processus — par conséquent, des défaillances de production. Les panneaux solaires sont situés sur un seul plan de toit, sur une coque de panneau sandwich, fixé à une structure de support située dans le même plan que le plan du toit. La structure de support fixe les panneaux solaires à l’aide de fixations standard en acier inoxydable et de rails de montage solaires. Système d’usine recommandé: Faire K2. L’entrée côté DC de l’onduleur est reliée à un total de 166 pcs 300 Wp Canadian Solar HC poly (cellule coupée polycristallin) panneaux solaires. Parmi ces panneaux solaires 4x20 sont les onduleurs hybrides 4 Fronius SYMO 5 kW, 1x86 pcs panneau solaire fournit la charge latérale DC de Fronius SYMO 25 kW inverseur. La méthode de commutation des panneaux solaires, la connexion des chaînes individuelles, est incluse dans les feuilles de conception qui font partie du plan. Les plans de mise en page des panneaux solaires sur le plan du toit, ainsi que le positionnement des onduleurs et la trace de la ligne AC jusqu’au séparateur principal, sont indiqués dans les feuilles de conception jointes. (French)
    10 February 2022
    0 references
    Balmazújváros, Hajdú-Bihar
    0 references