(10360.14072017.115000100) CALVINO (Q2057010): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Changed an Item)
(‎Created claim: summary (P836): AND? DO YOU PROVIDE FOR THE CONVERSION OF THE EXISTING BUILDING INTO NZEBS (NZEBS)? AS PROVIDED FOR IN ANNEX 1 TO THE MINISTERIAL DECREE OF 26 JUNE 2015? MINIMUM REQUIREMENTS? TO EXECUTE: — COIBENING OF THE EDGE WALLS THROUGH THE INSTALLATION OF AN OUTER EPS IN EPS (? = 0,034 W/MK,? = 40 KG/M3), SO AS TO GUARANTEE A THERMAL TRANSMITTANCE OF LESS THAN 0,23 W/MQK; REMOTE MANAGEMENT OF REMOTE INSTALLATIONS; — SUBSTITUTION OF THE CURRENT GLASS SURFA...)
Property / summary
 
AND? DO YOU PROVIDE FOR THE CONVERSION OF THE EXISTING BUILDING INTO NZEBS (NZEBS)? AS PROVIDED FOR IN ANNEX 1 TO THE MINISTERIAL DECREE OF 26 JUNE 2015? MINIMUM REQUIREMENTS? TO EXECUTE: — COIBENING OF THE EDGE WALLS THROUGH THE INSTALLATION OF AN OUTER EPS IN EPS (? = 0,034 W/MK,? = 40 KG/M3), SO AS TO GUARANTEE A THERMAL TRANSMITTANCE OF LESS THAN 0,23 W/MQK; REMOTE MANAGEMENT OF REMOTE INSTALLATIONS; — SUBSTITUTION OF THE CURRENT GLASS SURFACES WITH FRAMES WITH PVC FRAMES TO 5 HOLLOW CHAMBERS AND VETARMERA 3 + 3/15/3 + 3 WITH LOW EMISSIONS FILLED IN ARGON; AND SUBSTITUTION OF THE CURRENT HEAT GENERATOR TO METHANE WITH AIR/WATER HEAT PUMP AND REPLACEMENT OF (English)
Property / summary: AND? DO YOU PROVIDE FOR THE CONVERSION OF THE EXISTING BUILDING INTO NZEBS (NZEBS)? AS PROVIDED FOR IN ANNEX 1 TO THE MINISTERIAL DECREE OF 26 JUNE 2015? MINIMUM REQUIREMENTS? TO EXECUTE: — COIBENING OF THE EDGE WALLS THROUGH THE INSTALLATION OF AN OUTER EPS IN EPS (? = 0,034 W/MK,? = 40 KG/M3), SO AS TO GUARANTEE A THERMAL TRANSMITTANCE OF LESS THAN 0,23 W/MQK; REMOTE MANAGEMENT OF REMOTE INSTALLATIONS; — SUBSTITUTION OF THE CURRENT GLASS SURFACES WITH FRAMES WITH PVC FRAMES TO 5 HOLLOW CHAMBERS AND VETARMERA 3 + 3/15/3 + 3 WITH LOW EMISSIONS FILLED IN ARGON; AND SUBSTITUTION OF THE CURRENT HEAT GENERATOR TO METHANE WITH AIR/WATER HEAT PUMP AND REPLACEMENT OF (English) / rank
 
Normal rank

Revision as of 09:58, 23 March 2020

Project in Italy financed by DG Regio
Language Label Description Also known as
English
(10360.14072017.115000100) CALVINO
Project in Italy financed by DG Regio

    Statements

    0 references
    145,527.21 Euro
    0 references
    593,988.62 Euro
    0 references
    24.5 percent
    0 references
    3 April 2018
    0 references
    3 April 2020
    0 references
    16 November 2020
    0 references
    COMUNE DI SERAVEZZA
    0 references
    0 references

    43°46'11.53"N, 11°15'20.09"E
    0 references
    E? PREVISTA LA TRASFORMAZIONE DELL?EDIFICIO ESISTENTE IN EDIFICIO AD ENERGIA QUASI ZERO (NZEB) COS? COME PREVISTO DALL?ALLEGATO 1 DEL D.M. 26 GIUGNO 2015 ?REQUISITI MINIMI?.SI ANDR? AD ESEGUIRE:-COIBENTAZIONE DELLE PARETI PERIMETRALI ATTRAVERSO LA POSA DI UN CAPPOTTO ESTERNO IN EPS (?=0,034 W/MK, ?=40 KG/M3), TALE DA GARANTIRE TRASMITTANZE TERMICHE INFERIORI A 0,23 W/MQK;-COIBENTAZIONE DELLA COPERTURA DELL?EDIFICIO MEDIANTE USO DI MATERIALEI ISOLANTI TALI DA GARANTIRE TRASMITTANZE TERMICHE PARI O INFERIORI A 0,20 W/MQK;-INSTALLAZIONE DI UN SISTEMA DI BUILDING AUTOMATION CON CRONOTERMOSTATO E VALVOLE TERMOSTATICHE WIRELESS SU OGNI CORPO SCALDANTE CON POSSIBILIT? DI TELEGESTIONE DEGLI IMPIANTI DA REMOTO;-SOSTITUZIONE DELLE ATTUALI SUPERFICI VETRATE CON SERRAMENTI AVENTI TELAIO IN PVC A 5 CAMERE CAVE E VETROCAMERA 3+3/15/3+3 CON TRATTAMENTO BASSO EMISSIVO RIEMPITA IN GAS ARGON;-SOSTITUZIONE DELL?ATTUALE GENERATORE DI CALORE A METANO CON POMPA DI CALORE ARIA/ACQUA E SOSTITUZIONE DEGLI (Italian)
    0 references
    AND? DO YOU PROVIDE FOR THE CONVERSION OF THE EXISTING BUILDING INTO NZEBS (NZEBS)? AS PROVIDED FOR IN ANNEX 1 TO THE MINISTERIAL DECREE OF 26 JUNE 2015? MINIMUM REQUIREMENTS? TO EXECUTE: — COIBENING OF THE EDGE WALLS THROUGH THE INSTALLATION OF AN OUTER EPS IN EPS (? = 0,034 W/MK,? = 40 KG/M3), SO AS TO GUARANTEE A THERMAL TRANSMITTANCE OF LESS THAN 0,23 W/MQK; REMOTE MANAGEMENT OF REMOTE INSTALLATIONS; — SUBSTITUTION OF THE CURRENT GLASS SURFACES WITH FRAMES WITH PVC FRAMES TO 5 HOLLOW CHAMBERS AND VETARMERA 3 + 3/15/3 + 3 WITH LOW EMISSIONS FILLED IN ARGON; AND SUBSTITUTION OF THE CURRENT HEAT GENERATOR TO METHANE WITH AIR/WATER HEAT PUMP AND REPLACEMENT OF (English)
    0 references

    Identifiers