(10360.14072017.115000236) E. MUNICIPAL SWIMMING POOL (Q2057110): Difference between revisions
Jump to navigation
Jump to search
(Changed label, description and/or aliases in nl, and other parts: Adding Dutch translations) |
(Changed label, description and/or aliases in de, and other parts: Adding German translations) |
||||||||||||||
label / de | label / de | ||||||||||||||
(10360.14072017.115000236) E. E. KOMMUNALES SCHWIMMBAD | |||||||||||||||
Property / summary | |||||||||||||||
MASSNAHME 1: WÄRMEDÄMMUNG VERTIKALER STRUKTUREN NACH DEM GERÜST WIRD DURCHGEFÜHRT, UM DIE VORHANDENE BESCHICHTUNG ZU ENTFERNEN UND DIE BETONWAND UNTEN ZU REINIGEN. DANN GEHEN WIR ZUR ANWENDUNG DER ISOLIERPLATTE DES EXTRUDIERTEN POLYSTYROLS MIT EINER DICKE VON 10 CM (? = 0,028 W/MQ*K) HAFTUNG AN DER WAND DURCH KLEBEN. DIE ARBEIT WIRD DURCH DIE AUFBRINGUNG EINER BESCHICHTUNG, BESTEHEND AUS EINER PLATTE MIT EINER SANDWICHSTRUKTUR IN AUFGEHELLTEM ZEMENTKONGLOMERAT MIT EINER DICKE VON 12 MM, BEIDSEITIG DURCH EIN FIBERGLASGEWEBE, DAS SEHR WIDERSTANDSFÄHIG GEGEN LACALS.INTERVENT 2: ERSATZ VON FENSTER- UND FENSTERRAHMEN SOLLTE DAS GLASFENSTERSYSTEM? MIT DER GESETZLICH VORGESCHRIEBENEN ÜBERTRAGUNG AUF DEN WERT VON U 1,3 W/MQK ÜBEREINSTIMMEN. DIE INTERVENTION MUSS DIE LIEFERUNG UND DEN EINBAU VON RAHMEN AUS VERZINKTEM STAHL UMFASSEN, DIE MIT CHEMISCHEN ANKERN UND STAHLSTIFTEN IN BETRIEB GENOMMEN WERDEN, WENN SIE NICHT VORHANDEN ODER UNGEEIGNET SIND. (German) | |||||||||||||||
Property / summary: MASSNAHME 1: WÄRMEDÄMMUNG VERTIKALER STRUKTUREN NACH DEM GERÜST WIRD DURCHGEFÜHRT, UM DIE VORHANDENE BESCHICHTUNG ZU ENTFERNEN UND DIE BETONWAND UNTEN ZU REINIGEN. DANN GEHEN WIR ZUR ANWENDUNG DER ISOLIERPLATTE DES EXTRUDIERTEN POLYSTYROLS MIT EINER DICKE VON 10 CM (? = 0,028 W/MQ*K) HAFTUNG AN DER WAND DURCH KLEBEN. DIE ARBEIT WIRD DURCH DIE AUFBRINGUNG EINER BESCHICHTUNG, BESTEHEND AUS EINER PLATTE MIT EINER SANDWICHSTRUKTUR IN AUFGEHELLTEM ZEMENTKONGLOMERAT MIT EINER DICKE VON 12 MM, BEIDSEITIG DURCH EIN FIBERGLASGEWEBE, DAS SEHR WIDERSTANDSFÄHIG GEGEN LACALS.INTERVENT 2: ERSATZ VON FENSTER- UND FENSTERRAHMEN SOLLTE DAS GLASFENSTERSYSTEM? MIT DER GESETZLICH VORGESCHRIEBENEN ÜBERTRAGUNG AUF DEN WERT VON U 1,3 W/MQK ÜBEREINSTIMMEN. DIE INTERVENTION MUSS DIE LIEFERUNG UND DEN EINBAU VON RAHMEN AUS VERZINKTEM STAHL UMFASSEN, DIE MIT CHEMISCHEN ANKERN UND STAHLSTIFTEN IN BETRIEB GENOMMEN WERDEN, WENN SIE NICHT VORHANDEN ODER UNGEEIGNET SIND. (German) / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / summary: MASSNAHME 1: WÄRMEDÄMMUNG VERTIKALER STRUKTUREN NACH DEM GERÜST WIRD DURCHGEFÜHRT, UM DIE VORHANDENE BESCHICHTUNG ZU ENTFERNEN UND DIE BETONWAND UNTEN ZU REINIGEN. DANN GEHEN WIR ZUR ANWENDUNG DER ISOLIERPLATTE DES EXTRUDIERTEN POLYSTYROLS MIT EINER DICKE VON 10 CM (? = 0,028 W/MQ*K) HAFTUNG AN DER WAND DURCH KLEBEN. DIE ARBEIT WIRD DURCH DIE AUFBRINGUNG EINER BESCHICHTUNG, BESTEHEND AUS EINER PLATTE MIT EINER SANDWICHSTRUKTUR IN AUFGEHELLTEM ZEMENTKONGLOMERAT MIT EINER DICKE VON 12 MM, BEIDSEITIG DURCH EIN FIBERGLASGEWEBE, DAS SEHR WIDERSTANDSFÄHIG GEGEN LACALS.INTERVENT 2: ERSATZ VON FENSTER- UND FENSTERRAHMEN SOLLTE DAS GLASFENSTERSYSTEM? MIT DER GESETZLICH VORGESCHRIEBENEN ÜBERTRAGUNG AUF DEN WERT VON U 1,3 W/MQK ÜBEREINSTIMMEN. DIE INTERVENTION MUSS DIE LIEFERUNG UND DEN EINBAU VON RAHMEN AUS VERZINKTEM STAHL UMFASSEN, DIE MIT CHEMISCHEN ANKERN UND STAHLSTIFTEN IN BETRIEB GENOMMEN WERDEN, WENN SIE NICHT VORHANDEN ODER UNGEEIGNET SIND. (German) / qualifier | |||||||||||||||
point in time: 24 December 2021
|
Revision as of 12:30, 24 December 2021
Project Q2057110 in Italy
Language | Label | Description | Also known as |
---|---|---|---|
English | (10360.14072017.115000236) E. MUNICIPAL SWIMMING POOL |
Project Q2057110 in Italy |
Statements
162,834.56 Euro
0 references
437,492.1 Euro
0 references
37.22 percent
0 references
3 April 2018
0 references
3 April 2020
0 references
16 November 2020
0 references
COMUNE DI BIBBIENA
0 references
INTERVENTO 1: ISOLAMENTO TERMICO DI STRUTTURE VERTICALI IN SEGUITO ALL?ALLESTIMENTO DEL PONTEGGIO SI PROCEDE ALLA RIMOZIONE DEL RIVESTIMENTO ESISTENTE E ALLA PULIZIA DELLA PARETE IN CALCESTRUZZO SOTTOSTANTE. SUCCESSIVAMENTE SI PROCEDE ALLA APPLICAZIONE DI PANNELLO COIBENTE DI POLISTIRENE ESTRUSO DELLO SPESSORE DI 10 CM (? = 0,028 W/MQ*K) IN ADERENZA ALLA PARETE MEDIANTE INCOLLAGGIO. L?OPERA VIENE COMPLETATA CON L?APPLICAZIONE DI RIVESTIMENTO COSTITUITO DA LASTRA CON STRUTTURA A SANDWICH IN CONGLOMERATO CEMENTIZIO ALLEGGERITO DELLO SPESSORE DI 12 MM, ARMATA SU ENTRAMBI I LATI DA UNA RETE IN FIBRA DI VETRO ALTAMENTE RESISTENTE AGLI ALCALI.INTERVENTO 2: SOSTITUZIONE DI SERRAMENTI ED INFISSI IL SISTEMA FINESTRA VETRO DOVR? ESSERE RISPONDENTE ALLA TRASMITTANZA PRESCRITTA PER LEGGE FISSATA NEL VALORE DI U 1,3 W/MQK. NELL?INTERVENTO SI DEVE COMPRENDERE LA FORNITURA E POSA DI CONTROTELAI IN ACCIAIO ZINCATO MESSI IN OPERA CON ANCORANTE CHIMICO E PERNI IN ACCIAIO OVE NON PRESENTI O NON IDONEI QU (Italian)
0 references
ACTION 1: THERMAL INSULATION OF VERTICAL STRUCTURES FOLLOWING THE SCAFFOLDING IS SET UP, THE EXISTING COATING IS REMOVED AND THE CONCRETE WALL IS CLEANED. SUBSEQUENTLY, HAVE EXTRUDED POLYSTYRENE IN THE THICKNESS OF 10 CM (? = 0,028 W/M²) IN ADHESION TO THE WALL BY BONDING. L? WORKS IS COMPLETED WITH THE COATING COATING MADE OF SANDWICH PANELS WITH A LIGHT CONGLOMERATE SANDWICH STRUCTURE WITH A THICKNESS OF 12 MM, ON BOTH SIDES WITH A HIGHLY RESISTANT GLASS FIBRE NETWORK IN ALCALI.INTERVENTO 2: WINDOW FRAMES AND WINDOWS IN THE GLASS WINDOW? BE COMPLIANT WITH THE STATUTORY TRANSMITTANCE SET IN U 1,3 W/MQK. IN? INTERVENTION, IT IS NECESSARY TO INCLUDE THE SUPPLY AND INSTALLATION OF GALVANISED STEEL ROPES AND FRAMES MADE BY CHEMICALS AND STUDS MADE OF STEEL WHEN NOT PRESENT OR UNFIT. (English)
0 references
ACTION 1: L’ISOLATION THERMIQUE DES STRUCTURES VERTICALES SUIVANT L’ÉCHAFAUDAGE EST RÉALISÉE POUR ENLEVER LE REVÊTEMENT EXISTANT ET NETTOYER LE MUR EN BÉTON CI-DESSOUS. ENSUITE, NOUS PROCÉDONS À L’APPLICATION D’UN PANNEAU ISOLANT DE POLYSTYRÈNE EXTRUDÉ D’UNE ÉPAISSEUR DE 10 CM (? = 0,028 W/MQ*K) ADHÉRENCE AU MUR PAR COLLAGE. LES TRAVAUX SONT COMPLÉTÉS PAR L’APPLICATION D’UN REVÊTEMENT CONSTITUÉ D’UNE DALLE AVEC UNE STRUCTURE SANDWICHE EN CONGLOMÉRAT DE CIMENT ÉCLAIRÉ D’UNE ÉPAISSEUR DE 12 MM, ARMÉ DES DEUX CÔTÉS D’UNE MAILLE EN FIBRE DE VERRE TRÈS RÉSISTANTE À LACALS.INTERVENT 2: REMPLACEMENT DES FENÊTRES ET DES CADRES DE FENÊTRES LE SYSTÈME DE FENÊTRES EN VERRE DEVRAIT? ÊTRE COMPATIBLE AVEC LA TRANSMISSION PRESCRITE PAR LA LOI FIXÉE À LA VALEUR U 1,3 W/MQK. L’INTERVENTION DOIT INCLURE LA FOURNITURE ET L’INSTALLATION DE CADRES EN ACIER GALVANISÉ MIS EN SERVICE AVEC DES ANCRAGES CHIMIQUES ET DES BROCHES EN ACIER LORSQU’ILS NE SONT PAS PRÉSENTS OU INADAPTÉS. (French)
16 December 2021
0 references
ACTIE 1: THERMISCHE ISOLATIE VAN VERTICALE CONSTRUCTIES NA DE STEIGER WORDT UITGEVOERD OM DE BESTAANDE COATING TE VERWIJDEREN EN DE BETONWAND HIERONDER TE REINIGEN. DAN GAAN WE VERDER MET DE TOEPASSING VAN ISOLATIEPANEEL VAN GEËXTRUDEERD POLYSTYREEN MET EEN DIKTE VAN 10 CM (? = 0.028 W/MQ*K) HECHTING AAN DE MUUR DOOR LIJMEN. HET WERK WORDT VOLTOOID DOOR HET AANBRENGEN VAN EEN COATING BESTAANDE UIT EEN PLAAT MET EEN SANDWICHSTRUCTUUR IN VERLICHT CEMENTCONGLOMERAAT MET EEN DIKTE VAN 12 MM, AAN BEIDE ZIJDEN BEWAPEND DOOR EEN GLASVEZELNETWERK DAT ZEER BESTAND IS TEGEN LACALS.INTERVENT 2: VERVANGING VAN RAMEN EN RAAMKOZIJNEN HET GLAZEN RAAMSYSTEEM MOET? IN OVEREENSTEMMING ZIJN MET DE DOOR DE WET VOORGESCHREVEN TRANSMISSIE OP DE WAARDE VAN U 1,3 W/MQK. DE INTERVENTIE OMVAT DE LEVERING EN INSTALLATIE VAN GEGALVANISEERDE STALEN FRAMES DIE MET CHEMISCHE ANKERS EN STALEN PINNEN IN WERKING WORDEN GESTELD WANNEER ZIJ NIET AANWEZIG OF ONGESCHIKT ZIJN. (Dutch)
23 December 2021
0 references
MASSNAHME 1: WÄRMEDÄMMUNG VERTIKALER STRUKTUREN NACH DEM GERÜST WIRD DURCHGEFÜHRT, UM DIE VORHANDENE BESCHICHTUNG ZU ENTFERNEN UND DIE BETONWAND UNTEN ZU REINIGEN. DANN GEHEN WIR ZUR ANWENDUNG DER ISOLIERPLATTE DES EXTRUDIERTEN POLYSTYROLS MIT EINER DICKE VON 10 CM (? = 0,028 W/MQ*K) HAFTUNG AN DER WAND DURCH KLEBEN. DIE ARBEIT WIRD DURCH DIE AUFBRINGUNG EINER BESCHICHTUNG, BESTEHEND AUS EINER PLATTE MIT EINER SANDWICHSTRUKTUR IN AUFGEHELLTEM ZEMENTKONGLOMERAT MIT EINER DICKE VON 12 MM, BEIDSEITIG DURCH EIN FIBERGLASGEWEBE, DAS SEHR WIDERSTANDSFÄHIG GEGEN LACALS.INTERVENT 2: ERSATZ VON FENSTER- UND FENSTERRAHMEN SOLLTE DAS GLASFENSTERSYSTEM? MIT DER GESETZLICH VORGESCHRIEBENEN ÜBERTRAGUNG AUF DEN WERT VON U 1,3 W/MQK ÜBEREINSTIMMEN. DIE INTERVENTION MUSS DIE LIEFERUNG UND DEN EINBAU VON RAHMEN AUS VERZINKTEM STAHL UMFASSEN, DIE MIT CHEMISCHEN ANKERN UND STAHLSTIFTEN IN BETRIEB GENOMMEN WERDEN, WENN SIE NICHT VORHANDEN ODER UNGEEIGNET SIND. (German)
24 December 2021
0 references
Identifiers
J38J18000070002
0 references