Q3109422 (Q3109422): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Changed an Item: Edited by the materialized bot - inferring region from the coordinates)
(‎Created claim: summary (P836): The main objective of this project is to develop efficient district heating (CZT) systems based on useful heat demand in Dunajská Streda. The project has 1 specific objective: Increase the efficiency of district heating operation of the K18-Mlyny circuit.  It will be implemented through 1 main activity: Reconstruction of central heat supply circuit K18 – Mlyny. The project solves the design of the reconstruction of CZT, which will supply heat to...)
Property / summary
 
The main objective of this project is to develop efficient district heating (CZT) systems based on useful heat demand in Dunajská Streda. The project has 1 specific objective: Increase the efficiency of district heating operation of the K18-Mlyny circuit.  It will be implemented through 1 main activity: Reconstruction of central heat supply circuit K18 – Mlyny. The project solves the design of the reconstruction of CZT, which will supply heat to buildings by a 2-tube hot water system from the existing boiler room K18 – Mlyny, with nominal parameters 95 °C, PN 6. New hot water compact heat transfer points (DOST) will be set up at each point of delivery. New hot water distributions connect to the existing gas boiler room K18 – Mlyny.The proposed route is a line building, which is located on the territory of the town Dunajská Streda, K18 – Mlyny boiler room, Square of friendship, ul. Jilemnického, ul. New Ves, ul. Attilu József and ul. It’s flax. All routes of new divorces are designed in underground design.The expected length of the route of the primary divorce:  1978 m. Thanks to the project dosiahne:zníženie heat loss in pipelines,reduction of dimensions of pre-extensified existing pipelines,cancellation of external distribution of DHW,reduction of water leakage in pipelines due to leakage of pipelines,reduction of repair costs for pipe failures.Reduction of energy intensity in heat distribution,reduction of ecological burden of the environment by reducing discharge of pollutants,reduction of greenhouse gas emissions.The project will contribute to the fulfillment of measurable indicators: Estimated annual greenhouse gas emission reductions – 224,4 t eqiv. CO2/year; Saving PEZ district heating systems – 1102,35 MWh/year; Number of district heating systems with higher efficiency – 1. (English)
Property / summary: The main objective of this project is to develop efficient district heating (CZT) systems based on useful heat demand in Dunajská Streda. The project has 1 specific objective: Increase the efficiency of district heating operation of the K18-Mlyny circuit.  It will be implemented through 1 main activity: Reconstruction of central heat supply circuit K18 – Mlyny. The project solves the design of the reconstruction of CZT, which will supply heat to buildings by a 2-tube hot water system from the existing boiler room K18 – Mlyny, with nominal parameters 95 °C, PN 6. New hot water compact heat transfer points (DOST) will be set up at each point of delivery. New hot water distributions connect to the existing gas boiler room K18 – Mlyny.The proposed route is a line building, which is located on the territory of the town Dunajská Streda, K18 – Mlyny boiler room, Square of friendship, ul. Jilemnického, ul. New Ves, ul. Attilu József and ul. It’s flax. All routes of new divorces are designed in underground design.The expected length of the route of the primary divorce:  1978 m. Thanks to the project dosiahne:zníženie heat loss in pipelines,reduction of dimensions of pre-extensified existing pipelines,cancellation of external distribution of DHW,reduction of water leakage in pipelines due to leakage of pipelines,reduction of repair costs for pipe failures.Reduction of energy intensity in heat distribution,reduction of ecological burden of the environment by reducing discharge of pollutants,reduction of greenhouse gas emissions.The project will contribute to the fulfillment of measurable indicators: Estimated annual greenhouse gas emission reductions – 224,4 t eqiv. CO2/year; Saving PEZ district heating systems – 1102,35 MWh/year; Number of district heating systems with higher efficiency – 1. (English) / rank
 
Normal rank
Property / summary: The main objective of this project is to develop efficient district heating (CZT) systems based on useful heat demand in Dunajská Streda. The project has 1 specific objective: Increase the efficiency of district heating operation of the K18-Mlyny circuit.  It will be implemented through 1 main activity: Reconstruction of central heat supply circuit K18 – Mlyny. The project solves the design of the reconstruction of CZT, which will supply heat to buildings by a 2-tube hot water system from the existing boiler room K18 – Mlyny, with nominal parameters 95 °C, PN 6. New hot water compact heat transfer points (DOST) will be set up at each point of delivery. New hot water distributions connect to the existing gas boiler room K18 – Mlyny.The proposed route is a line building, which is located on the territory of the town Dunajská Streda, K18 – Mlyny boiler room, Square of friendship, ul. Jilemnického, ul. New Ves, ul. Attilu József and ul. It’s flax. All routes of new divorces are designed in underground design.The expected length of the route of the primary divorce:  1978 m. Thanks to the project dosiahne:zníženie heat loss in pipelines,reduction of dimensions of pre-extensified existing pipelines,cancellation of external distribution of DHW,reduction of water leakage in pipelines due to leakage of pipelines,reduction of repair costs for pipe failures.Reduction of energy intensity in heat distribution,reduction of ecological burden of the environment by reducing discharge of pollutants,reduction of greenhouse gas emissions.The project will contribute to the fulfillment of measurable indicators: Estimated annual greenhouse gas emission reductions – 224,4 t eqiv. CO2/year; Saving PEZ district heating systems – 1102,35 MWh/year; Number of district heating systems with higher efficiency – 1. (English) / qualifier
 
point in time: 15 September 2021
Timestamp+2021-09-15T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0

Revision as of 16:31, 15 September 2021

Project Q3109422 in Slovakia
Language Label Description Also known as
English
No label defined
Project Q3109422 in Slovakia

    Statements

    0 references
    1,272,395.03 Euro
    0 references
    1,496,935.33 Euro
    0 references
    0.85 percent
    0 references
    3 January 2018
    0 references
    9 January 2018
    0 references
    SOUTHERM, s.r.o.
    0 references

    47°59'29.87"N, 17°37'14.27"E
    0 references
    Hlavným cieľom predkladaného projektu je rozvoj účinných   systémov centralizovaného zásobovania teplom (CZT) založených na dopyte po využiteľnom teple v meste Dunajská Streda.Projekt má 1 špecifický cieľ: Zvýšenie efektívnosti prevádzky centralizovaného zásobovania teplom okruhu K18 – Mlyny.  Bude sa realizovať prostredníctvom 1 hlavnej aktivity: Rekonštrukcia centrálneho zásobovania tepla okruhu K18 – Mlyny.Projekt rieši návrh rekonštrukcie CZT, ktoré bude dodávať teplo do objektov 2-rúrovým teplovodným systémom z jestvujúcej kotolne K18 - Mlyny, s menovitými parametrami 95 °C, PN 6. V jednotlivých odberných miestach sa zriadia nové teplovodné domové kompaktné odovzdávacie stanice tepla (DOST). Nové teplovodné rozvody sa napoja na existujúcu plynovú kotolňu K18 - Mlyny.Navrhovaná trasa je líniová stavba, ktorá je osadená na území mesta Dunajská Streda, okruh kotolne K18 - Mlyny, Námestie priateľstva, ul. Jilemnického, ul. Nová Ves, ul. Attilu Józsefa a ul. Ľanárska. Všetky trasy nových rozvodov sú navrhnuté v podzemnom vyhotovení.Predpokladaná dĺžka trasy primárneho rozvodu:  1978 m.Vďaka projektu sa dosiahne:zníženie tepelných strát v potrubných rozvodoch,zníženie dimenzií predimenzovaných existujúcich rozvodov ÚK,zrušenie vonkajších rozvodov TÚV,zníženie únikov vody v potrubných vedeniach vplyvom netesnosti potrubí,zníženie nákladov na opravy pri poruchách potrubí.zníženie energetickej náročnosti pri distribúcii tepla,zníženie ekologickej záťaže životného prostredia znížením vypúšťania znečisťujúcich látok,zníženie emisií skleníkových plynov.Projekt prispeje svojim zameraním k naplneniu merateľných ukazovateľov: Odhadované ročné zníženie emisií skleníkových plynov – 224,4 t ekviv. CO2/rok; Úspora PEZ  systémoch centralizovaného zásobovania teplom – 1 102,35 MWh/rok; Počet systémov centralizovaného zásobovania teplom s vyššou účinnosťou – 1. (Slovak)
    0 references
    The main objective of this project is to develop efficient district heating (CZT) systems based on useful heat demand in Dunajská Streda. The project has 1 specific objective: Increase the efficiency of district heating operation of the K18-Mlyny circuit.  It will be implemented through 1 main activity: Reconstruction of central heat supply circuit K18 – Mlyny. The project solves the design of the reconstruction of CZT, which will supply heat to buildings by a 2-tube hot water system from the existing boiler room K18 – Mlyny, with nominal parameters 95 °C, PN 6. New hot water compact heat transfer points (DOST) will be set up at each point of delivery. New hot water distributions connect to the existing gas boiler room K18 – Mlyny.The proposed route is a line building, which is located on the territory of the town Dunajská Streda, K18 – Mlyny boiler room, Square of friendship, ul. Jilemnického, ul. New Ves, ul. Attilu József and ul. It’s flax. All routes of new divorces are designed in underground design.The expected length of the route of the primary divorce:  1978 m. Thanks to the project dosiahne:zníženie heat loss in pipelines,reduction of dimensions of pre-extensified existing pipelines,cancellation of external distribution of DHW,reduction of water leakage in pipelines due to leakage of pipelines,reduction of repair costs for pipe failures.Reduction of energy intensity in heat distribution,reduction of ecological burden of the environment by reducing discharge of pollutants,reduction of greenhouse gas emissions.The project will contribute to the fulfillment of measurable indicators: Estimated annual greenhouse gas emission reductions – 224,4 t eqiv. CO2/year; Saving PEZ district heating systems – 1102,35 MWh/year; Number of district heating systems with higher efficiency – 1. (English)
    15 September 2021
    0 references

    Identifiers

    310041I489
    0 references