(Created claim: summary (P836): Specific works applied to the thermal insulation of the hospital building envelopes (outdoor walls, windows, carpentry, floor above the last floor floor over the basement, etc.), of sarpents and wrappers including finishing works, by installing a modern mechanical ventilation system with energy recovery, by replacing the installations for preparing, distributing and using the heating agent for heating and hot water, installing high energy valves...) |
||||||||||||||
Property / summary | |||||||||||||||
Specific works applied to the thermal insulation of the hospital building envelopes (outdoor walls, windows, carpentry, floor above the last floor floor over the basement, etc.), of sarpents and wrappers including finishing works, by installing a modern mechanical ventilation system with energy recovery, by replacing the installations for preparing, distributing and using the heating agent for heating and hot water, installing high energy valves with high energy consumption, changing the life of the fluorescent bodies. (English) | |||||||||||||||
Property / summary: Specific works applied to the thermal insulation of the hospital building envelopes (outdoor walls, windows, carpentry, floor above the last floor floor over the basement, etc.), of sarpents and wrappers including finishing works, by installing a modern mechanical ventilation system with energy recovery, by replacing the installations for preparing, distributing and using the heating agent for heating and hot water, installing high energy valves with high energy consumption, changing the life of the fluorescent bodies. (English) / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / summary: Specific works applied to the thermal insulation of the hospital building envelopes (outdoor walls, windows, carpentry, floor above the last floor floor over the basement, etc.), of sarpents and wrappers including finishing works, by installing a modern mechanical ventilation system with energy recovery, by replacing the installations for preparing, distributing and using the heating agent for heating and hot water, installing high energy valves with high energy consumption, changing the life of the fluorescent bodies. (English) / qualifier | |||||||||||||||
point in time: 17 June 2021
|
Revision as of 12:03, 17 June 2021
Project Q2744892 in Romania
Language | Label | Description | Also known as |
---|---|---|---|
English | No label defined |
Project Q2744892 in Romania |
Statements
10,910,973.6685 Romanian Leu
0 references
12,836,439.610000001 Romanian Leu
0 references
0.85 percent
0 references
13 June 2018
0 references
31 May 2021
0 references
SPITALUL MUNICIPAL ORASTIE
0 references
Lucrari specifice aplicate izolatiei termice a anvelopei cladirilor spitalului (pereti exteriori, ferestre, tamplarie, planseu peste ultimul nivel planseu peste subsol, etc), a sarpantelor si invelitorilor inclusiv lucrari de finisaje, prin instalarea unui sistem de ventilare mecanica modern cu recuperarea energiei, prin inlocuirea instalatiilor pentru prepararea, distributia si utilizarea agentului termic pentru incalzire si pentru apa calda, instalarea de robineti monobloc cu senzor, inlocuirea corpurilor de iluminat fluorescent cu corpuri de iluminat cu eficienta energetica ridicata si durata mare de viata - corpuri de tip LED, respectiv prin inlocuirea a 3 lifturi mari consumatoare de energie cu altele noi, menite sa reduca pierderile de energie electrica. (Romanian)
0 references
Specific works applied to the thermal insulation of the hospital building envelopes (outdoor walls, windows, carpentry, floor above the last floor floor over the basement, etc.), of sarpents and wrappers including finishing works, by installing a modern mechanical ventilation system with energy recovery, by replacing the installations for preparing, distributing and using the heating agent for heating and hot water, installing high energy valves with high energy consumption, changing the life of the fluorescent bodies. (English)
17 June 2021
0 references
Hunedoara, Orăștie
0 references
Identifiers
115658
0 references