Energy modernisation of the municipal building in Łukawiec and the School Complex building in Jasionka (Q118672): Difference between revisions
Jump to navigation
Jump to search
(Changed label, description and/or aliases in 1 language: translated_label) |
(Changed label, description and/or aliases in 2 languages: Changing unique label-description pair) |
||
description / en | description / en | ||
Project in Poland | Project Q118672 in Poland | ||
description / pl | description / pl | ||
Projekt w Polsce | Projekt Q118672 w Polsce |
Revision as of 15:43, 29 October 2020
Project Q118672 in Poland
Language | Label | Description | Also known as |
---|---|---|---|
English | Energy modernisation of the municipal building in Łukawiec and the School Complex building in Jasionka |
Project Q118672 in Poland |
Statements
434,655.92 zloty
0 references
511,359.97 zloty
0 references
85.0 percent
0 references
23 March 2016
0 references
31 October 2017
0 references
GMINA TRZEBOWNISKO
0 references
Projekt obejmuje zadania inwestycyjne polegające na wykonaniu prac termomodernizacyjnych w 2 budynkach użyteczności publicznej zlokalizowanych w gminie Trzebownisko : 1. Budynek użyteczności publicznej w Łukawcu, 2. Budynek Zespołu Szkół w Jasionce, Dotychczasowy stan techniczny i energetyczny budynków objętych projektem jest dalece niezadowalający. Budynki wykazują znaczne straty energii cieplnej co spowodowane jest nieocieplonymi ścianami, stropami i nieefektywnym systemem cieplnym. W budynku komunalnym w Łukawcu zaplanowano:- izolacja ścian budynku styropianem o współczynniku przewodzenia ciepła ? = 0,033 W/(m*K),- ocieplenie stropodachu płytami wełny mineralnej o współczynniku przewodzenia ciepła ? = 0,035 W/(m*K), - wymiana starych okien na nowe o współczynniku przenikania ciepła nie gorszym niż U = 0,9 W/(m2*K), - wymiana starych drzwi na nowe o współczynniku przenikania ciepła nie gorszym niż U = 1,3 W/(m2*K), -modernizacja systemu CWU. Likwidacja lokalnych podgrzewaczy elektrycznych i montaż centralnej instalacji CWU zasilanej z kotła gazowego,- modernizacja systemu grzewczego. W budynku Zespołu Szkół w Jasionce zaplanowano:- ocieplenie stropu zewnętrznego (poddasze) płytami wełny mineralnej o współczynniku przewodzenia ciepła ? = 0,033 W/(m*K),- wymiana starych drzwi zewnętrznych na nowe o współczynniku przenikania ciepła nie gorszym niż U = 1,3 W/(m2*K), - wymiana starych okien zewnętrznych na nowe o współczynniku przenikania ciepła nie gorszym niż U = 0,9 W/(m2*K).Realizacja inwestycji pozwoli na uzyskanie:1. W budynku komunalnym w Łukawcu wskaźnika EP na poziomie 202,95 [kWh/m2/rok] oraz zostanie zmniejszone zapotrzebowanie na zużycie energii o 77%,2. W budynku ZS w Jasionce wskaźnika EP na poziomie 198,40 [kWh/m2/rok] oraz zostanie zmniejszone zapotrzebowanie na zużycie energii o 25%, W wyniku projektu prace termomodernizacyjne przeprowadzone zostaną w dwóch budynkach o łącznej kubaturze 15 961,08 m3. (Polish)
0 references
The project includes investment tasks consisting of carrying out thermal modernisation works in 2 public buildings located in Trzebownisko commune: 1. Public utility building in Łukawiec, 2. The building of the School Complex in Jasionka, The technical and energy status of the buildings covered by the project is extremely unsatisfactory. Buildings show significant thermal energy losses due to unwarming walls, ceilings and inefficient heat system. In the municipal building in Łukawiec it is planned:- insulation of the walls of the building with styrofoam coefficient? = 0,033 W/(m*K),- glazing with mineral wool plates with heat conduction coefficient? = 0,035 W/(m*K), – replacement of old windows with a heat transfer coefficient not worse than U = 0,9 W/(m²*K), – replacement of old doors with a heat transfer coefficient not worse than U = 1,3 W/(m²*K), -modernisation of the CWU system. Liquidation of local electric heaters and installation of central CWU system powered by a gas boiler,- modernisation of the heating system. In the building of the School Complex in Jasionka it is planned:- warming of the outer ceiling (attic) with mineral wool plates with heat conduction coefficient? = 0,033 W/(m*K),- replacement of old external doors for new ones with a heat transfer coefficient not worse than U = 1,3 W/(m²*K), – replacement of old external windows with a heat transfer coefficient not worse than U = 0,9 W/(m²*K). In the municipal building in Łukawiec, the EP index of 202.95 [kWh/m²/year] will be reduced and the demand for energy consumption will be reduced by 77 %,2. In the ZS building in Jasionka the EP indicator of 198.40 [kWh/m²/year] and the demand for energy consumption will be reduced by 25 %. As a result of the project, thermal modernisation works will be carried out in two buildings with a total volume of 15961.08 m³. (English)
20 October 2020
0 references
Identifiers
RPPK.03.02.00-18-0037/16
0 references