COMPREHENSIVE THERMAL RENOVATION OF THE SCHOOL TEAM WITH AN ADDITIONAL SCIENCE OF BELARUSIAN LANGUAGE IN HAJNÓWKA (Q116991): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Changed an Item: Fixing rounding issue)
(‎Removed claim: summary (P836): The project, due to very poor thermal insulation parameters and, consequently, the exceptionally low energy efficiency of the building, provides for the following construction works: * The insulation of fundamental walls in the base of polystyrene extruded at 12 cm, * insulation of the wall wall of core styropiate Foundation by 12 cm, * insulation of the outer wall at the level of floor height of the facades by 15 cm with trim of silicon and/o...)
Property / summary
The project, due to very poor thermal insulation parameters and, consequently, the exceptionally low energy efficiency of the building, provides for the following construction works: * The insulation of fundamental walls in the base of polystyrene extruded at 12 cm, * insulation of the wall wall of core styropiate Foundation by 12 cm, * insulation of the outer wall at the level of floor height of the facades by 15 cm with trim of silicon and/or silicon wool in the composition of the ‘Baranek’, * insulation of the ventilation valve above the ground mineral wool by 30 cm, * replacement of the floor with a non-ventilated mineral wool by 10 cm, * replacement of the interior of the lighting with a non-ventilated mineral wool by 10 cm, * replacement of the interior lighting system with 2 cm ventilation unit and exhaust heat recovery, * replacement of a heat interchange, * installation of solar panels with a combined output of 15 kWp. According to estimates made in the energy audit every year, 6245 GJ of final energy are used for heating and hot water and lighting for hot water. The execution of the above works will allow it to be reduced by around 52 %. This will entail a reduction in CO2 emissions of 294 tonnes. (English)
 
Property / summary: The project, due to very poor thermal insulation parameters and, consequently, the exceptionally low energy efficiency of the building, provides for the following construction works: * The insulation of fundamental walls in the base of polystyrene extruded at 12 cm, * insulation of the wall wall of core styropiate Foundation by 12 cm, * insulation of the outer wall at the level of floor height of the facades by 15 cm with trim of silicon and/or silicon wool in the composition of the ‘Baranek’, * insulation of the ventilation valve above the ground mineral wool by 30 cm, * replacement of the floor with a non-ventilated mineral wool by 10 cm, * replacement of the interior of the lighting with a non-ventilated mineral wool by 10 cm, * replacement of the interior lighting system with 2 cm ventilation unit and exhaust heat recovery, * replacement of a heat interchange, * installation of solar panels with a combined output of 15 kWp. According to estimates made in the energy audit every year, 6245 GJ of final energy are used for heating and hot water and lighting for hot water. The execution of the above works will allow it to be reduced by around 52 %. This will entail a reduction in CO2 emissions of 294 tonnes. (English) / rank
Normal rank
 

Revision as of 15:19, 20 October 2020

Project in Poland financed by DG Regio
Language Label Description Also known as
English
COMPREHENSIVE THERMAL RENOVATION OF THE SCHOOL TEAM WITH AN ADDITIONAL SCIENCE OF BELARUSIAN LANGUAGE IN HAJNÓWKA
Project in Poland financed by DG Regio

    Statements

    0 references
    1,305,448.2 zloty
    0 references
    313,307.57 Euro
    13 January 2020
    0 references
    1,864,926.0 zloty
    0 references
    447,582.24 Euro
    13 January 2020
    0 references
    70.0 percent
    0 references
    27 July 2017
    0 references
    13 September 2018
    0 references
    POWIAT HAJNOWSKI
    0 references

    52°43'54.1"N, 23°34'16.3"E
    0 references
    Projekt ze względu na bardzo złe parametry izolacyjności termicznej, a co za tym idzie wyjątkowo niską efektywność energetyczną budynku przewiduje wykonanie następujących prac budowlanych: * ocieplenie ścian fundamentowych w gruncie polistyrenem ekstrudowanym o gr. 12 cm, * wykonanie docieplenia ścian cokołów styropianem fundamentowym o gr. 12 cm, * ocieplenie ścian zewnętrznych na poziomie kondygnacji styropianem fasadowym o gr. 15 cm z wykończeniem tynkiem krzemianowo-silikonowym lub silikonowym w uziarnieniu „baranek”, * ocieplenie stropów wentylowanych nad parterowymi przybudówkami, łącznikiem dwukondygnacyjnym z salą gimnastyczną oraz aulą granulatem wełny mineralnej gr. 30 cm metodą „wdmuchiwania ciepła”, * izolację stropu poddasza nieużytkowego styropianem, * izolację stropu nad klatką schodową styropianem o gr. 10 cm, * docieplenie stropodachów niewentylowanych wełną mineralną o gr. 10 cm wraz z wykonaniem pokrycia dachowego papą termozgrzewalną, * wymianę części oświetlenia wbudowanego na energooszczędne typu LED, * zastąpienie dwóch układów wentylacji mechanicznej kuchni i jadalni 2 centralami wentylacyjnymi nawiewno-wywiewnymi z wymiennikiem obrotowym oraz odzyskiem ciepła z powietrza wywiewanego, * wymianę węzła cieplnego, * instalację paneli fotowoltaicznych o łącznej mocy 15 kWp. Zgodnie z szacunkami zawartymi w audycie energetycznym każdego roku na ogrzewanie budynku i przygotowanie ciepłej wody oraz oświetlenie zużywanych jest 6245 GJ energii końcowej. Przeprowadzenie wymienionych wyżej robót pozwoli na jej ograniczenie o około 52%. Wiązać się to będzie ze zmniejszeniem emisji CO2 rzędu 294 ton. (Polish)
    0 references

    Identifiers

    RPPD.05.03.01-20-0094/16
    0 references