Insulation (thermal modernisation) of Gymnasium, upgrading the staircase and the insulation and reconstruction of the bridge of the building complex in Adamowo (Q105394): Difference between revisions
Jump to navigation
Jump to search
(Changed an Item: Fixing rounding issue) |
(Removed claim: summary (P836): The main objective is to improve the efficiency of the use of energy in the public buildings of the municipality of Adamów. Improving air quality in the municipality. In administrative terms, the municipality belongs to the Lubelskie region and to the district of Lukowskiego. The building is the property of the Adamów municipality, which is located at ul. KLEEEBGA 5, Adamów. Project indicators: Amount of thermal energy saved GJ/year — 1001,1,...) |
||
Property / summary | |||
Property / summary: The main objective is to improve the efficiency of the use of energy in the public buildings of the municipality of Adamów. Improving air quality in the municipality. In administrative terms, the municipality belongs to the Lubelskie region and to the district of Lukowskiego. The building is the property of the Adamów municipality, which is located at ul. KLEEEBGA 5, Adamów. Project indicators: Amount of thermal energy saved GJ/year — 1001,1, Reduction of annual primary energy consumption in public buildings (CI32) 228 100 kWh/year, estimated annual decrease in greenhouse gas emissions (CI34) 51,2 tonnes/year, thermal energy production from newly built/emerging energy. DIA. RES 253,4 MWHT/year, Number of renovated units generating heat from RES — 1 tonnes, Number of energy modernised buildings — 1 unit, usable area of buildings renovated 2 611.2 m², Number of facilities for refurbishment. — 1, Additional capacity for generating renewable heat of 0.2 MW, additional capacity for power generation from renewable sources 0.2 MW. the project scope includes the insulation of walls and floors — replacement of joinery, modernisation of the installation of c.. exchange of heat source with automation and metering system, replacement of lighting with energy-efficient. According to the SOOP guidelines, requirements have been adopted since 1.01.2021 by the Regulation (Dz. (Polish Journal of Laws of 18.09.2015, item EUR 1422). The wall insulation has been assumed in light wet technology (s), steep (s) with the injected pellet (s), the lead factor 0,036-0,037. The window is used with a U-value of = 0,7 W/m²/K, door 1,2 W/m²/K. the project will also establish an energy management system, data collected from the sensors and the data entered manually in the system and will identify the most critical moments of production or consumption. The target group is students, teachers and residents. The facility will be adapted to meet the needs of the people of incomplete ones. (English) / rank | |||
Revision as of 08:59, 20 October 2020
Project in Poland financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | Insulation (thermal modernisation) of Gymnasium, upgrading the staircase and the insulation and reconstruction of the bridge of the building complex in Adamowo |
Project in Poland financed by DG Regio |
Statements
1,271,090.31 zloty
0 references
1,495,400.37 zloty
0 references
85.0 percent
0 references
18 October 2016
0 references
30 October 2018
0 references
GMINA ADAMÓW
0 references
Celem głównym jest Poprawa efektywności wykorzystania energii w budynkach użyteczności publicznej Gminy Adamów. Poprawa jakości powietrza na terenie Gminy. Pod względem administracyjnym gmina należy do województwa lubelskiego i powiatu łukowskiego. Budynek stanowi własność Gminy Adamów z siedzibą przy ul. Kleeberga 5 w Adamowie. Wskaźniki projektu: Ilość zaoszczędzonej energii cieplnej GJ/rok - 1001,1, Zmniejszenie rocznego zużycia energii pierwotnej w budynkach publicznych (CI32) 228100 kWh/rok, Szacowany roczny spadek emisji gazów cieplarnianych (CI34) 51,2 Tony/rok, , Produkcja energii cieplnej z nowo wybudowanych/nowych inst. Wyk. OZE 253,4 MWht/rok, Liczba przebudowanych jednostek wytwarzania energii cieplnej z OZE - 1 szt, Liczba zmodernizowanych energetycznie budynków - 1 szt, Powierzchnia użytkowa budynków poddanych termomodernizacji 2611,2 m2, Liczba obiektów dostos. dla osób z niepełn. - 1, Dodatkowa zdolność wytwarzania energii cieplnej ze źródeł odnawialnych 0,2 MW, Dodatkowa zdolność wytwarzania energii ze źródeł odnawialnych 0,2 MW Zakres rzeczowy projektu obejmuje docieplenie ścian i stropów -, wymianę stolarki, modernizacja instalacji c. o. wymiana źródła ciepła wraz z automatyką i układem opomiarowania, wymiana oświetlenia na energooszczędne. Zgodnie z wytycznymi zawartymi w SOOP (RPO WL) przyjęto wymagania w tym zakresie obowiązujące od 1.01.2021 według rozporządzenia (Dz. U. z 18.09.2015 r., poz. 1422). Docieplenie ścian założono w technologii lekkiej mokrej, stropów za pomocą wdmuchiwanego granulatu - współczynnik przewodzenia 0,036 - 0,037. Okna zastosowano o współczynniku U = 0,7 W/m2/K, drzwi 1,2 W/m2/K. W wyniku realizacji projektu powstanie również system zarządzania energią, Dane zbierane z czujników i dane wprowadzane ręcznie będą przetwarzane w systemie i pozwolą zidentyfikować najbardziej krytyczne momenty produkcji czy zużycia. Grupą docelową są uczniowie, nauczyciele oraz mieszkańcy. Obiekt zostanie dostos. dla potrzeb osób niepełn. (Polish)
0 references
Identifiers
RPLU.05.02.00-06-0079/16
0 references