(‎Removed claim: summary (P836): As a result of the project, innovative technology will be put in place for the production of halogen electric cables for construction works with enhanced fire requirements.The new technology will allow the production of high-performance cables B2ca and Cca which, by virtue of the manufacturing technology and the materials used, will constitute a product in Poland and a cable that maintains their functions during a fire for a minimum of 120 min...)
(‎Created claim: summary (P836): As a result of the project, innovative technology of production of halogen-free power cables will be implemented for applications in buildings with increased fire protection requirements. Thanks to the new technology, it will be possible to manufacture cables with high fire resistance classes B2ca and Cca, which due to the technology of manufacturing and used materials will be a product innovation in Poland and cables that maintain their functio...)
Property / summary
 
As a result of the project, innovative technology of production of halogen-free power cables will be implemented for applications in buildings with increased fire protection requirements. Thanks to the new technology, it will be possible to manufacture cables with high fire resistance classes B2ca and Cca, which due to the technology of manufacturing and used materials will be a product innovation in Poland and cables that maintain their functions during the fire for at least 120 minutes, which are not produced in Poland at all. (English)
Property / summary: As a result of the project, innovative technology of production of halogen-free power cables will be implemented for applications in buildings with increased fire protection requirements. Thanks to the new technology, it will be possible to manufacture cables with high fire resistance classes B2ca and Cca, which due to the technology of manufacturing and used materials will be a product innovation in Poland and cables that maintain their functions during the fire for at least 120 minutes, which are not produced in Poland at all. (English) / rank
 
Normal rank
Property / summary: As a result of the project, innovative technology of production of halogen-free power cables will be implemented for applications in buildings with increased fire protection requirements. Thanks to the new technology, it will be possible to manufacture cables with high fire resistance classes B2ca and Cca, which due to the technology of manufacturing and used materials will be a product innovation in Poland and cables that maintain their functions during the fire for at least 120 minutes, which are not produced in Poland at all. (English) / qualifier
 
point in time: 14 October 2020
Timestamp+2020-10-14T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0

Revision as of 11:40, 14 October 2020

Project in Poland financed by DG Regio
Language Label Description Also known as
English
Non halogen cables for use in enhanced firefighting facilities
Project in Poland financed by DG Regio

    Statements

    0 references
    4,603,499.99 zloty
    0 references
    1,104,840.00 Euro
    13 January 2020
    0 references
    10,230,000.0 zloty
    0 references
    2,455,200.0 Euro
    13 January 2020
    0 references
    45.0 percent
    0 references
    1 May 2016
    0 references
    31 January 2019
    0 references
    TECHNOKABEL SPÓŁKA AKCYJNA
    0 references
    0 references
    W wyniku realizowanego projektu zostanie wdrożona innowacyjna technologia produkcji bezhalogenowych kabli elektroenergetycznych do zastosowań w obiektach budowlanych o podwyższonych wymaganiach przeciwpożarowych. Dzięki nowej technologii będzie możliwa produkcja kabli o wysokich klasach odporności ogniowej B2ca oraz Cca, które z racji technologii wytworzenia oraz użytych materiałów będą stanowić innowację produktową na terenie Polsce oraz kable utrzymujące swoje funkcje w trakcie pożaru przez minimum 120 minut, które nie są w Polsce w ogóle produkowane. (Polish)
    0 references
    As a result of the project, innovative technology of production of halogen-free power cables will be implemented for applications in buildings with increased fire protection requirements. Thanks to the new technology, it will be possible to manufacture cables with high fire resistance classes B2ca and Cca, which due to the technology of manufacturing and used materials will be a product innovation in Poland and cables that maintain their functions during the fire for at least 120 minutes, which are not produced in Poland at all. (English)
    14 October 2020
    0 references

    Identifiers

    POIR.03.02.02-00-0337/16
    0 references