Comprehensive thermal upgrade of the building of the Primary School of Saint Bran Albert in Sierrock (Q112282): Difference between revisions
Jump to navigation
Jump to search
(Changed an Item) |
(Removed claim: EU contribution (P835): 159,705.9048 euro) |
||||||||||||||
Property / EU contribution | |||||||||||||||
| |||||||||||||||
Property / EU contribution: 159,705.9048 Euro / rank | |||||||||||||||
Property / EU contribution: 159,705.9048 Euro / qualifier | |||||||||||||||
| |||||||||||||||
Property / EU contribution: 159,705.9048 Euro / qualifier | |||||||||||||||
|
Revision as of 08:42, 24 September 2020
Project in Poland financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | Comprehensive thermal upgrade of the building of the Primary School of Saint Bran Albert in Sierrock |
Project in Poland financed by DG Regio |
Statements
665,441.27 zloty
0 references
1,312,507.5 zloty
0 references
50.7 percent
0 references
1 February 2019
0 references
31 December 2019
0 references
GMINA BIAŁY DUNAJEC
0 references
W ramach realizacji projektu przewiduje się: -Ocieplenie ścian zewnętrznych budynku szkoły płytami styropianowymi metodą lekką-mokrą przy użyciu gotowych zapraw klejących - grubość płyt 15 cm, styropian grafitowy współczynnik przewodzenia ciepła 0,031 W/mK, uzyskany współczynnik przenikania ciepła ścian U = 0,19 W/(m2xK). -Ocieplenie dachu współczynnik przenikania ciepła U = 0,13 W/(m2xK ) (montaż wełny mineralnej, otynkowanie kominów), -Montaż paneli fotowoltaicznych polikrystalicznych na dachu łączna moc 8,4 kW -Remont wewnętrznej instalacji elektrycznej z wprowadzeniem automatycznych wyłączników, regulacje prowadzącą do utrzymania oświetlenia na poziomie wymaganym, ściemniacze fotokomórkowe z czułością na światło dzienne. -Kompleksowa modernizacja instalacji CO (piony, przewody rozprowadzające, grzejniki, zawory termostatyczne o działaniu proporcjonalno-całkującym PI z funkcjami adaptacyjną i optymalizującą, system zarządzania centralnym ogrzewaniem BMS). -Montaż głębinowej pompy ciepła o mocy 42 kW typu woda-woda wraz z odwiertami w gruncie do 30m. -Montaż i wpięcie do wewnętrznej instalacji elektrycznej paneli fotowoltaicznych na dachu – 30 paneli polikrystalicznych o mocy 280 W. Razem moc 8,4 kW. W wyniku realizacji przedsięwzięcia nastąpi zmniejszenie rocznego zapotrzebowanie na energię końcową do ogrzewania budynku z 446770 kWh/rok do 58742,23 kWh/rok. Łączna oszczędność energii końcowej dla budynku wynosi 86,85 %. W wyniku realizacji projektu osiągnięta zostanie 100 % obniżenia emisji pyłów PM 10 i PM 2,5 oraz 80,177707 % redukcji emisji CO2 jaka zostanie osiągnięta w projekcie w stosunku do stanu sprzed realizacji projektu. Zastosowane będą obowiązkowe urządzenia służące do rozliczania ciepła oraz utrzymujące zadaną temperaturę. Kubatura części ogrzewanej budynku wynosi 9089,46 m3, powierzchnia użytkowa netto 1754,63m2. (Polish)
0 references
As part of the implementation of the project, the following are foreseen: — the insulation of the outer wall of the styrofoam plate with a wet process method by means of a wet process by means of a wet process with the use of ready-to-use adhesive rights — the thickness of the plates 15 cm, a graphic contact factor of 0,031 W/mK, obtained by the heat penetration factor of the wall of U = 0,19 W/(m2xK). — thermal insulation of the U-roof = 0,13 W/(m2xK) (installation of mineral wool, washing chimneys), -installation of roof panels for solar photovoltaic panels on the roof with a combined effect of 8.4 kW — renovation of the internal electrical installation with the introduction of automatic circuit-breakers, regulations leading to the retention of lighting up to the required level, photolysis cell sensors and sensitivity to daylight. — A comprehensive modernisation of the CO (beer, distribution, radiators, radiators, thermostatic radiators, PI with adaptive and optimised functions, BMS central heating system). — Deep-sea waste of this heat pump with a water-water type of 42 kW with wells up to 30 m. — Installation and floor for internal electrical installation of solar panels on the roof — 30 polycrystalline panels with a power of 280 W. Total power 8.4 kW. The project will result in a reduction of the annual final energy demand for heating the building from 446 770 kWh/year to 58 742.23 kWh/year. The total final energy savings for the building is 86.85 %. The project will result in a 100 % reduction in PM 10 and PM 2,5 and a 80.177707 % reduction in CO2 emissions that will be achieved in the project compared to the situation prior to the project. Mandatory heat accounting equipment will be used and maintains the temperature. The volume of the building part of the heated building is 9 089.46 m³, with a net usable surface area of 1 754.63 m². (English)
0 references
Identifiers
RPMP.04.03.02-12-0320/16
0 references