(10360.14072017.115000171) ENERGY EFFICIENCY AND REGULATION OF THE MUNICIPALITY (Q4934461): Difference between revisions
Jump to navigation
Jump to search
(BatchIngestion) |
(Set a claim value: summary (P836): AS INTERVENÇÕES PROPOSTAS RELATIVAS À INTRODUÇÃO DE EDIFÍCIOS EM TODOS OS EDIFÍCIOS SÃO:? INSULAÇÃO DE PAREDE COM CASA EXTERIOR DE 4 CM COM ?= 0,0015 W/MQ?K PARA REALIZAR UMA TRANSMITÊNCIA GLOBAL INFERIOR A 0,24 W/MQ?K;? INSULAÇÃO DE PAVIMENTOS EM QUARTOS NÃO AQUECIDOS (ARMAZENAMENTO): 80 MM INTRADOX INSULATOR COM?=0,026 W/MQ?K, PARA REALIZAR UMA TRANSMITÊNCIA INFERIOR A 0,24 W/MQ?K;? INSULAR O EXTRADOXO DA TABELA SUPERIOR PARA ÁTICO NÃO MELHORADO,...) |
||||||
(One intermediate revision by the same user not shown) | |||||||
Property / summary: THE PROPOSED INTERVENTIONS CONCERNING THE BUILDING ENVELOPE OF BOTH BUILDINGS ARE:? WALL INSULATION WITH 4 CM OUTER COAT WITH?= 0.0015 W/MQ?K TO ACHIEVE AN OVERALL TRANSMITTANCE OF LESS THAN 0.24 W/MQ?K;? INSULATION OF FLOORS TO UNHEATED ROOMS (STORAGE): 80 MM INTRADOX INSULATOR WITH?=0.026 W/MQ?K, TO ACHIEVE A TRANSMITTANCE OF LESS THAN 0.24 W/MQ?K;? INSULATE THE EXTRADOX OF THE SUPERIOR SLAB TOWARDS UNHEATED ATTIC, WITH EXTRUDED FOAM POLYSTYRENE PANELS OF 100 MM THICKNESS AND CONDUCTIVITY? EQUAL TO 0.026 W/MQ?K, SO AS TO ACHIEVE A GLOBAL TRANSMITTANCE OF LESS THAN 0.24 W/MQ?K.? REPLACEMENT FIXTURES, WITH LOW EMISSION ONES WITH GLOBAL TRANSMITTANCE LESS THAN 1.0 W/MQ?K? REPLACEMENT OF DIESEL BOILER WITH DISTRICT HEATING NETWORK CONNECTION AND HEAT PUMP INSTALLATION? INSTALLATION OF ENERGY MONITORING SYSTEM? INSTALLATION OF LIGHTING MANAGEMENT SYSTEM? INSTALLATION OF PHOTOVOLTAIC SYSTEM COMP (English) / qualifier | |||||||
readability score: 0.2533919489791769
| |||||||
Property / summary | Property / summary | ||||||
AS INTERVENÇÕES PROPOSTAS RELATIVAS À INTRODUÇÃO DE EDIFÍCIOS EM TODOS OS EDIFÍCIOS SÃO:? INSULAÇÃO DE PAREDE COM CASA EXTERIOR DE 4 CM COM ?= 0,0015 W/MQ?K PARA REALIZAR UMA TRANSMITÊNCIA GLOBAL INFERIOR A 0,24 W/MQ?K;? INSULAÇÃO DE PAVIMENTOS EM QUARTOS NÃO AQUECIDOS (ARMAZENAMENTO): 80 MM INTRADOX INSULATOR COM?=0,026 W/MQ?K, PARA REALIZAR UMA TRANSMITÊNCIA INFERIOR A 0,24 W/MQ?K;? INSULAR O EXTRADOXO DA TABELA SUPERIOR PARA ÁTICO NÃO MELHORADO, COM PANÉIS EXTRUDIDOS DE POLISTIRENO DE ALMA DE 100 MM DE ESPESSURA E CONDUTIVIDADE? Igual a 0,026 W/MQ?K, de modo a alcançar uma transmissão global inferior a 0,24 W/MQ?K.? FIXAÇÕES DE SUBSTITUIÇÃO, COM LINHAS DE EMISSÕES COM TRANSMITÊNCIA GLOBAL INFERIOR A 1,0 W/MQ?K? Substituição da caldeira a diesel por uma ligação à rede de aquecimento distrital e instalação de bombas de calor? INSTALAÇÃO DO SISTEMA DE MONITORIZAÇÃO ENERGÉTICA? INSTALAÇÃO DO SISTEMA DE GESTÃO DA ILUMINAÇÃO? INSTALAÇÃO DO SISTEMA FOTOVOLTÁTICO COMP (Portuguese) |
Latest revision as of 19:27, 12 October 2024
Project Q4934461 in Italy
Language | Label | Description | Also known as |
---|---|---|---|
English | (10360.14072017.115000171) ENERGY EFFICIENCY AND REGULATION OF THE MUNICIPALITY |
Project Q4934461 in Italy |
Statements
95,112.1 Euro
0 references
213,126.97 Euro
0 references
44.63 percent
0 references
16 November 2018
0 references
16 November 2020
0 references
COMUNE DI CAREGGINE
0 references
GLI INTERVENTI PROPOSTI CHE RIGUARDANO L?INVOLUCRO EDILIZIO DI ENTRAMBI GLI EDIFICI SONO:? ISOLAMENTO DELLE PARETI CON CAPPOTTO ESTERNO DA 4 CM CON ?= 0.0015 W/MQ?K PER OTTENERE UNA TRASMITTANZA GLOBALE INFERIORE A 0.24 W/MQ?K;? ISOLAMENTO DEI SOLAI VERSO LOCALI NON RISCALDATI (MAGAZZINO): ISOLANTE INTRADOSSO DA 80 MM CON ?=0.026 W/MQ ?K, PER OTTENERE UNA TRASMITTANZA INFERIORE A 0.24 W/MQ ?K;? ISOLARE L?ESTRADOSSO DEL SOLAIO SUPERIOR VERSO SOTTOTETTO NON RISCALDATO, CON PANNELLI IN POLISTIRENE ESPANSO ESTRUSO DI SPESSORE 100 MM E DI CONDUTTIVIT? PARI A 0.026 W/MQ ?K, IN MODO DA RAGGIUNGERE UNA TRASMITTANZA GLOBALE INFERIORE A 0.24 W/MQ ?K.? SOSTITUZIONE INFISSI, CON QUELLI A BASSA EMISSIONE CON TRASMITTANZA GLOBALE INFERIORE A 1.0 W/MQ ?K? SOSTITUZIONE CALDAIA A GASOLIO CON ALLACCIO A RETE DI TELERISCALDAMENTO E INSTALLAZIONE POMPA DI CALORE? INSTALLAZIONE SISTEMA DI MONITORAGGIO ENERGETICO? INSTALLAZIONE SISTEMA DI GESTIONE DELL?ILLUMINAZIONE? INSTALLAZIONE IMPIANTO FOTOVOLTAICO COMP (Italian)
0 references
ПРЕДЛОЖЕНИТЕ ИНТЕРВЕНЦИИ ПО ОТНОШЕНИЕ НА ОГРАЖДАЩИТЕ ЕЛЕМЕНТИ НА ДВЕТЕ СГРАДИ СА: ИЗОЛАЦИЯ НА СТЕНИТЕ С 4 CM ВЪНШНО ПОКРИТИЕ С?= 0,0015 W/MQ?K ЗА ПОСТИГАНЕ НА ОБЩА ПРОПУСКЛИВОСТ ПО-МАЛКА ОТ 0,24 W/MQ?K; ИЗОЛАЦИЯ НА ПОДОВЕТЕ ДО НЕОТОПЛЯЕМИ ПОМЕЩЕНИЯ (СЪХРАНЕНИЕ): 80 MM ИНТРАДОКСОВ ИЗОЛАТОР С?=0,026 W/MQ?K, ЗА ДА СЕ ПОСТИГНЕ ПРОПУСКЛИВОСТ ПО-МАЛКА ОТ 0,24 W/MQ?K; ИЗОЛИРАЙТЕ ЕКСТРАДОКСА НА ПРЕВЪЗХОДНАТА ПЛОЧА КЪМ НЕОТОПЛЯЕМ ТАВАН, С ЕКСТРУДИРАНИ ПЕНОПОЛИСТИРОЛНИ ПАНЕЛИ С ДЕБЕЛИНА 100 ММ И ПРОВОДИМОСТ? РАВНО НА 0,026 W/MQ?K, ТАКА ЧЕ ДА СЕ ПОСТИГНЕ ГЛОБАЛНА ПРОПУСКЛИВОСТ ПО-МАЛКА ОТ 0,24 W/MQ? РЕЗЕРВНИ ТЕЛА С НИСКИ ЕМИСИИ С ГЛОБАЛНА ПРОПУСКЛИВОСТ ПО-МАЛКА ОТ 1,0 W/MQ?K? ПОДМЯНА НА ДИЗЕЛОВ КОТЕЛ С ТОПЛОФИКАЦИОННА МРЕЖА И ТЕРМОПОМПЕНА ИНСТАЛАЦИЯ? ИНСТАЛИРАНЕ НА СИСТЕМА ЗА ЕНЕРГИЕН МОНИТОРИНГ? ИНСТАЛИРАНЕ НА СИСТЕМА ЗА УПРАВЛЕНИЕ НА ОСВЕТЛЕНИЕТО? МОНТАЖ НА ФОТОВОЛТАИЧНА СИСТЕМА COMP (Bulgarian)
0 references
NAVRHOVANÉ ZÁSAHY TÝKAJÍCÍ SE OBVODOVÉHO PLÁŠTĚ OBOU BUDOV JSOU: IZOLACE STĚN S VNĚJŠÍM PLÁŠTĚM 4 CM S?= 0.0015 W/MQ?K PRO DOSAŽENÍ CELKOVÉ PROPUSTNOSTI MENŠÍ NEŽ 0,24 W/MQ?K;? IZOLACE PODLAH DO NEVYHŘÍVANÝCH MÍSTNOSTÍ (SKLADOVÁNÍ): 80 MM INTRADOXNÍ IZOLÁTOR S?=0.026 W/MQ?K, ABY BYLO DOSAŽENO PROPUSTNOSTI MENŠÍ NEŽ 0,24 W/MQ?K;? IZOLOVAT EXTRADOX VYNIKAJÍCÍ DESKY SMĚREM K NEZAHŘÁTÉ PODKROVÍ, S EXTRUDOVANÝMI PĚNOVÝMI POLYSTYRENOVÝMI PANELY O TLOUŠŤCE 100 MM A VODIVOSTI? ROVNÁ SE 0,026 W/MQ?K, ABY BYLO DOSAŽENO GLOBÁLNÍ PROPUSTNOSTI MENŠÍ NEŽ 0,24 W/MQ?K.? NÁHRADNÍ PŘÍSLUŠENSTVÍ S NÍZKÝMI EMISEMI S GLOBÁLNÍ PROPUSTNOSTÍ MENŠÍ NEŽ 1,0 W/MQ?K? VÝMĚNA DIESELOVÉHO KOTLE PŘIPOJENÍM SÍTĚ DÁLKOVÉHO VYTÁPĚNÍ A INSTALACÍ TEPELNÝCH ČERPADEL? INSTALACE SYSTÉMU MONITOROVÁNÍ ENERGIE? INSTALACE SYSTÉMU ŘÍZENÍ OSVĚTLENÍ? INSTALACE FOTOVOLTAICKÉHO SYSTÉMU COMP (Czech)
0 references
DE FORESLÅEDE INTERVENTIONER VEDRØRENDE KLIMARAMMEN FOR BEGGE BYGNINGER ER: VÆGISOLERING MED 4 CM YDERFRAKKE MED?= 0.0015 W/MQ?K FOR AT OPNÅ EN SAMLET TRANSMISSION PÅ MINDRE END 0,24 W/MQ?K;? ISOLERING AF GULVE TIL UOPVARMEDE RUM (OPBEVARING): 80 MM INTRADOX ISOLATOR MED?= 0,026 W/MQ?K, FOR AT OPNÅ EN TRANSMISSION PÅ MINDRE END 0,24 W/MQ?K;? ISOLERE EKSTRADOX AF DEN OVERLEGNE PLADE MOD UOPVARMEDE LOFTSRUM, MED EKSTRUDERET SKUM POLYSTYREN PANELER AF 100 MM TYKKELSE OG LEDNINGSEVNE? SVARENDE TIL 0,026 W/MQ?K, FOR AT OPNÅ EN GLOBAL TRANSMISSION PÅ MINDRE END 0,24 W/MQ?K.? UDSKIFTNINGSARMATURER, MED LAV EMISSION DEM MED GLOBAL TRANSMISSION MINDRE END 1,0 W/MQ?K? UDSKIFTNING AF DIESELKEDEL MED FJERNVARMENETTILSLUTNING OG VARMEPUMPEINSTALLATION? INSTALLATION AF ENERGIOVERVÅGNINGSSYSTEM? INSTALLATION AF BELYSNING MANAGEMENT SYSTEM? INSTALLATION AF SOLCELLEANLÆG COMP (Danish)
0 references
DIE VORGESCHLAGENEN MASSNAHMEN ZUR GEBÄUDEHÜLLE BEIDER GEBÄUDE SIND:? WANDDÄMMUNG MIT 4 CM AUSSENMANTEL MIT?= 0.0015 W/MQ?K, UM EINE GESAMTDURCHLÄSSIGKEIT VON WENIGER ALS 0,24 W/MQ?K ZU ERREICHEN;? ISOLIERUNG VON BÖDEN ZU UNBEHEIZTEN RÄUMEN (LAGER): 80 MM INTRADOXER ISOLATOR MIT? = 0,026 W/MQ?K, UM EINE DURCHLÄSSIGKEIT VON WENIGER ALS 0,24 W/MQ?K ZU ERREICHEN;? DAS EXTRADOX DER ÜBERLEGENEN PLATTE IN RICHTUNG UNBEHEIZTER DACHBODEN ISOLIEREN, MIT EXTRUDIERTEN POLYSTYROL-PLATTEN AUS SCHAUMSTOFF MIT EINER DICKE UND LEITFÄHIGKEIT VON 100 MM? ENTSPRICHT 0,026 W/MQ?K, UM EINE GLOBALE TRANSMISSION VON WENIGER ALS 0,24 W/MQ?K ZU ERREICHEN? ERSATZVORRICHTUNGEN, MIT EMISSIONSARMEN, MIT GLOBALER TRANSMISSION KLEINER ALS 1,0 W/MQ?K? ERSATZ VON DIESELKESSELN DURCH FERNWÄRMENETZANSCHLUSS UND WÄRMEPUMPENINSTALLATION? INSTALLATION EINES ENERGIEÜBERWACHUNGSSYSTEMS? INSTALLATION DES BELEUCHTUNGSMANAGEMENTSYSTEMS? INSTALLATION DER PHOTOVOLTAIKANLAGE COMP (German)
0 references
ΟΙ ΠΡΟΤΕΙΝΌΜΕΝΕΣ ΠΑΡΕΜΒΆΣΕΙΣ ΣΧΕΤΙΚΆ ΜΕ ΤΟ ΚΤΙΡΙΑΚΌ ΠΕΡΊΒΛΗΜΑ ΚΑΙ ΤΩΝ ΔΎΟ ΚΤΙΡΊΩΝ ΕΊΝΑΙ: ΜΌΝΩΣΗ ΤΟΊΧΩΝ ΜΕ ΕΞΩΤΕΡΙΚΌ ΠΑΛΤΌ 4 CM ΜΕ?= 0,0015 W/MQ? ΓΙΑ ΝΑ ΕΠΙΤΕΥΧΘΕΊ ΣΥΝΟΛΙΚΉ ΔΙΑΠΕΡΑΤΌΤΗΤΑ ΜΙΚΡΌΤΕΡΗ ΑΠΌ 0,24 W/MQ? ΜΌΝΩΣΗ ΔΑΠΈΔΩΝ ΣΕ ΜΗ ΘΕΡΜΑΙΝΌΜΕΝΑ ΔΩΜΆΤΙΑ (ΑΠΟΘΉΚΕΥΣΗ): 80 MM INSULATOR ΜΕ?=0,026 W/MQ? ΓΙΑ ΤΗΝ ΕΠΊΤΕΥΞΗ ΔΙΑΠΕΡΑΤΌΤΗΤΑΣ ΜΙΚΡΌΤΕΡΗ ΑΠΌ 0,24 W/MQ? ΜΟΝΏΣΤΕ ΤΟ EXTRADOX ΤΗΣ ΑΝΏΤΕΡΗΣ ΠΛΆΚΑΣ ΠΡΟΣ ΜΗ ΘΕΡΜΑΙΝΌΜΕΝΗ ΣΟΦΊΤΑ, ΜΕ ΕΞΩΘΗΜΈΝΑ ΠΆΝΕΛ ΑΠΌ ΑΦΡΏΔΕΣ ΠΟΛΥΣΤΥΡΈΝΙΟ ΠΆΧΟΥΣ ΚΑΙ ΑΓΩΓΙΜΌΤΗΤΑΣ 100 MM; ΊΣΗ ΜΕ 0,026 W/MQ?K, ΈΤΣΙ ΏΣΤΕ ΝΑ ΕΠΙΤΕΥΧΘΕΊ ΠΑΓΚΌΣΜΙΑ ΔΙΑΠΕΡΑΤΌΤΗΤΑ ΜΙΚΡΌΤΕΡΗ ΑΠΌ 0,24 W/MQ? ΑΝΤΑΛΛΑΚΤΙΚΆ ΦΩΤΙΣΤΙΚΆ, ΜΕ ΧΑΜΗΛΈΣ ΕΚΠΟΜΠΈΣ ΜΕ ΠΑΓΚΌΣΜΙΑ ΔΙΑΠΕΡΑΤΌΤΗΤΑ ΜΙΚΡΌΤΕΡΗ ΑΠΌ 1,0 W/MQ? ΑΝΤΙΚΑΤΆΣΤΑΣΗ ΛΈΒΗΤΑ ΝΤΊΖΕΛ ΜΕ ΣΎΝΔΕΣΗ ΔΙΚΤΎΟΥ ΤΗΛΕΘΈΡΜΑΝΣΗΣ ΚΑΙ ΕΓΚΑΤΆΣΤΑΣΗ ΑΝΤΛΙΏΝ ΘΕΡΜΌΤΗΤΑΣ; ΕΓΚΑΤΆΣΤΑΣΗ ΣΥΣΤΉΜΑΤΟΣ ΠΑΡΑΚΟΛΟΎΘΗΣΗΣ ΤΗΣ ΕΝΈΡΓΕΙΑΣ; ΕΓΚΑΤΆΣΤΑΣΗ ΣΥΣΤΉΜΑΤΟΣ ΔΙΑΧΕΊΡΙΣΗΣ ΦΩΤΙΣΜΟΎ; ΕΓΚΑΤΆΣΤΑΣΗ ΦΩΤΟΒΟΛΤΑΪΚΟΎ ΣΥΣΤΉΜΑΤΟΣ COMP (Greek)
0 references
THE PROPOSED INTERVENTIONS CONCERNING THE BUILDING ENVELOPE OF BOTH BUILDINGS ARE:? WALL INSULATION WITH 4 CM OUTER COAT WITH?= 0.0015 W/MQ?K TO ACHIEVE AN OVERALL TRANSMITTANCE OF LESS THAN 0.24 W/MQ?K;? INSULATION OF FLOORS TO UNHEATED ROOMS (STORAGE): 80 MM INTRADOX INSULATOR WITH?=0.026 W/MQ?K, TO ACHIEVE A TRANSMITTANCE OF LESS THAN 0.24 W/MQ?K;? INSULATE THE EXTRADOX OF THE SUPERIOR SLAB TOWARDS UNHEATED ATTIC, WITH EXTRUDED FOAM POLYSTYRENE PANELS OF 100 MM THICKNESS AND CONDUCTIVITY? EQUAL TO 0.026 W/MQ?K, SO AS TO ACHIEVE A GLOBAL TRANSMITTANCE OF LESS THAN 0.24 W/MQ?K.? REPLACEMENT FIXTURES, WITH LOW EMISSION ONES WITH GLOBAL TRANSMITTANCE LESS THAN 1.0 W/MQ?K? REPLACEMENT OF DIESEL BOILER WITH DISTRICT HEATING NETWORK CONNECTION AND HEAT PUMP INSTALLATION? INSTALLATION OF ENERGY MONITORING SYSTEM? INSTALLATION OF LIGHTING MANAGEMENT SYSTEM? INSTALLATION OF PHOTOVOLTAIC SYSTEM COMP (English)
0.2533919489791769
0 references
LAS INTERVENCIONES PROPUESTAS EN RELACIÓN CON LA ENVOLVENTE DEL EDIFICIO DE AMBOS EDIFICIOS SON: AISLAMIENTO DE PARED CON CAPA EXTERIOR DE 4 CM CON 0,0015 W/MQ?K PARA LOGRAR UNA TRANSMITANCIA TOTAL DE MENOS DE 0,24 W/MQ?K;? AISLAMIENTO DE SUELOS A HABITACIONES SIN CALEFACCIÓN (ALMACENAMIENTO): AISLADOR INTRADOX DE 80 MM CON?=0,026 W/MQ?K, PARA LOGRAR UNA TRANSMITANCIA INFERIOR A 0,24 W/MQ?K;? ¿AISLAR EL EXTRADOX DE LA LOSA SUPERIOR HACIA EL ÁTICO NO CALENTADO, CON PANELES DE POLIESTIRENO DE ESPUMA EXTRUIDA DE 100 MM DE ESPESOR Y CONDUCTIVIDAD? IGUAL A 0.026 W/MQ?K, PARA LOGRAR UNA TRANSMITANCIA GLOBAL DE MENOS DE 0,24 W/MQ?K.? ACCESORIOS DE REEMPLAZO, CON BAJAS EMISIONES CON TRANSMITANCIA GLOBAL INFERIOR A 1,0 W/MQ?K? ¿REEMPLAZO DE CALDERA DIESEL POR CONEXIÓN DE RED DE CALEFACCIÓN URBANA E INSTALACIÓN DE BOMBAS DE CALOR? ¿INSTALACIÓN DEL SISTEMA DE MONITOREO DE ENERGÍA? ¿INSTALACIÓN DEL SISTEMA DE GESTIÓN DE ILUMINACIÓN? INSTALACIÓN DEL SISTEMA FOTOVOLTAICO COMP (Spanish)
0 references
MÕLEMA HOONE HOONE VÄLISPIIRE KÄSITLEVAD KAVANDATUD SEKKUMISED ON JÄRGMISED: 4 CM VÄLISKIHIGA SEINAISOLATSIOONIGA?= 0,0015 W/MQ?K, ET SAAVUTADA ÜLDINE LÄBILASKVUS ALLA 0,24 W/MQ?K;? PÕRANDATE SOOJUSTAMINE SOOJENDAMATA RUUMIDESSE (LADUSTAMINE): 80 MM INTRADOKSISOLAATORIGA?=0,026 W/MQ?K, ET SAAVUTADA LÄBILASKVUS VÄHEM KUI 0,24 W/MQ?K;? ISOLEERIDA KÕRGEMA PLAADI EKSTRADOKSI KUUMUTAMATA PÖÖNINGU SUUNAS, 100 MM PAKSUSE JA JUHTIVUSEGA PRESSITUD VAHTPOLÜSTÜREENPANEELIDEGA? VÕRDNE 0,026 W/MQ?K, ET SAAVUTADA GLOBAALNE LÄBILASKVUS VÄHEM KUI 0,24 W/MQ?K.? ASENDUSSEADMED, MADALA EMISSIOONIGA, MILLE ÜLEMAAILMNE LÄBILASKVUS ON VÄIKSEM KUI 1,0 W/MQ?K? DIISELKATLA ASENDAMINE KAUGKÜTTEVÕRGU JA SOOJUSPUMPADE PAIGALDUSEGA? ENERGIASEIRESÜSTEEMI PAIGALDAMINE? VALGUSTUSE JUHTIMISSÜSTEEMI PAIGALDAMINE? FOTOGALVAANILISE SÜSTEEMI COMP PAIGALDAMINE (Estonian)
0 references
MOLEMPIEN RAKENNUSTEN VAIPPAA KOSKEVAT EHDOTETUT TOIMET OVAT SEURAAVAT: SEINÄERISTYKSEN 4 CM ULOMPI TAKKI?= 0,0015 W/MQ?K SAAVUTTAA KOKONAISLÄPÄISYKYKY ALLE 0,24 W/MQ?K;? LATTIOIDEN ERISTÄMINEN LÄMMITTÄMÄTTÖMIIN HUONEISIIN (VARASTOINTI): 80 MM: N INTRADOKSIERISTE, JONKA KANSSA?=0,026 W/MQ?K, SAAVUTTAA LÄPÄISEVYYS ALLE 0,24 W/MQ?K;? ERISTÄÄ YLIVOIMAISEN LAATAN EKSTRADOKSI KOHTI LÄMMITTÄMÄTÖNTÄ ULLAKKOA, SUULAKEPURISTETTUJA VAAHTOPOLYSTYREENIPANEELEJA, JOIDEN PAKSUUS ON 100 MM JA JOHTAVUUS? YHTÄ SUURI KUIN 0,026 W/MQ?K, JOTTA SAAVUTETAAN MAAILMANLAAJUINEN LÄPÄISYKYKY ALLE 0,24 W/MQ?K? KORVAAVAT KALUSTEET, JOISSA ON VÄHÄPÄÄSTÖISET, JOIDEN MAAILMANLAAJUINEN LÄPÄISYKYKY ON ALLE 1,0 W/MQ?K? DIESELKATTILAN KORVAAMINEN KAUKOLÄMPÖVERKOLLA JA LÄMPÖPUMPPUASENNUKSELLA? ENERGIANVALVONTAJÄRJESTELMÄN ASENTAMINEN? VALAISTUKSEN HALLINTAJÄRJESTELMÄN ASENNUS? AURINKOSÄHKÖJÄRJESTELMÄN ASENNUS COMP (Finnish)
0 references
LES INTERVENTIONS PROPOSÉES CONCERNANT L’ENVELOPPE IMMOBILIÈRE DES DEUX BÂTIMENTS SONT LES SUIVANTES:? ISOLATION MURALE AVEC COUCHE EXTÉRIEURE DE 4 CM AVEC?= 0,0015 W/MQ?K POUR OBTENIR UNE TRANSMISSION GLOBALE INFÉRIEURE À 0,24 W/MQ?K;? ISOLATION DES PLANCHERS AUX PIÈCES NON CHAUFFÉES (STOCKAGE): ISOLANT INTRADOX 80 MM AVEC?= 0,026 W/MQ?K, POUR OBTENIR UNE TRANSMISSION INFÉRIEURE À 0,24 W/MQ?K;? ISOLER L’EXTRADOX DE LA DALLE SUPÉRIEURE VERS LE GRENIER NON CHAUFFÉ, AVEC DES PANNEAUX EN POLYSTYRÈNE EN MOUSSE EXTRUDÉE D’ÉPAISSEUR ET DE CONDUCTIVITÉ DE 100 MM? ÉGAL À 0,026 W/MQ?K, AFIN D’OBTENIR UNE TRANSMISSION GLOBALE INFÉRIEURE À 0,24 W/MQ?K.? APPAREILS DE REMPLACEMENT, AVEC DES DISPOSITIFS À FAIBLE ÉMISSION AVEC TRANSMISSION GLOBALE INFÉRIEURE À 1,0 W/MQ?K? REMPLACEMENT DE LA CHAUDIÈRE DIESEL PAR RACCORDEMENT AU RÉSEAU DE CHAUFFAGE URBAIN ET INSTALLATION DE POMPES À CHALEUR? INSTALLATION D’UN SYSTÈME DE SURVEILLANCE DE L’ÉNERGIE? INSTALLATION D’UN SYSTÈME DE GESTION DE L’ÉCLAIRAGE? INSTALLATION D’UN SYSTÈME PHOTOVOLTAÏQUE COMP (French)
0 references
IS IAD SEO A LEANAS NA HIDIRGHABHÁLACHA ATÁ BEARTAITHE MAIDIR LE HIMCHLÚDACH FOIRGNIMH AN DÁ FHOIRGNEAMH:? INSLIÚ BALLA LE 4 CM CÓTA SEACHTRACH LE? = 0.0015 W/MQ?K A BHAINT AMACH TRANSMITTANCE FORIOMLÁN NÍOS LÚ NÁ 0.24 W/MQ?K;? URLÁR A INSLIÚ CHUIG SEOMRAÍ NEAMHTHÉITE (STÓRÁIL): 80 MM INTRADOX INSLITHEOIR LE? = 0.026 W/MQ?K, A BHAINT AMACH TRANSMITTANCE DE NÍOS LÚ NÁ 0.24 W/MQ?K;? DÉAN EXTRADOX AN LEAC NÍOS FEARR A INSLIÚ I DTREO ÁILÉIR NEAMHTHÉITE, LE PAINÉIL PHOLAISTIRÉIN CÚR EASBHRÚITE DE THIÚS AGUS SEOLTACHT 100 MM? COMHIONANN LE 0.026 W/MQ?K, IONAS GO MBAINFEAR TARCHUR DOMHANDA NÍOS LÚ NÁ 0.24 W/MQ?K.? DAINGNEÁIN ATHSHOLÁTHAIR, LE CINN ASTAÍOCHTAÍ ÍSLE LE TARCHUR DOMHANDA NÍOS LÚ NÁ 1.0 W/MQ?K? ATHSHOLÁTHAR COIRE DÍOSAIL LE NASC LÍONRA TÉIMH CEANTAIR AGUS SUITEÁIL CAIDÉIL TEASA? CÓRAS FAIREACHÁIN FUINNIMH A SHUITEÁIL? CÓRAS BAINISTÍOCHTA SOILSITHE A SHUITEÁIL? SUITEÁIL COMP CÓRAS FÓTAVOLTACH (Irish)
0 references
PREDLOŽENE INTERVENCIJE KOJE SE ODNOSE NA OVOJNICU ZGRADE OBIJU ZGRADA SU: ZIDNA IZOLACIJA S VANJSKIM SLOJEM OD 4 CM S?=0,0015 W/MQ?K KAKO BI SE POSTIGLA UKUPNA PROPUSNOST MANJA OD 0,24 W/MQ?K;? IZOLACIJA PODOVA U NEGRIJANE PROSTORIJE (SKLADIŠTENJE): 80 MM INTRADOX IZOLATOR S?=0,026 W/MQ?K, KAKO BI SE POSTIGLA PROPUSNOST MANJA OD 0,24 W/MQ?K;? IZOLIRATI EKSTRADOKS VRHUNSKE PLOČE PREMA NEGRIJANOM POTKROVLJU, S EKSTRUDIRANIM PJENASTIM POLISTIRENSKIM PLOČAMA DEBLJINE 100 MM I VODLJIVOSTI? JEDNAKA 0,066 W/MQ?K, KAKO BI SE POSTIGLA GLOBALNA PROPUSNOST MANJA OD 0,24 W/MQ? ZAMJENSKI UREĐAJI, S NISKIM EMISIJAMA S GLOBALNIM PRIJENOSOM MANJIM OD 1,0 W/MQ?K? ZAMJENA DIZELSKOG KOTLA S PRIKLJUČKOM NA MREŽU CENTRALIZIRANOG GRIJANJA I INSTALACIJOM DIZALICE TOPLINE? UGRADNJA SUSTAVA ZA PRAĆENJE ENERGIJE? INSTALACIJA SUSTAVA UPRAVLJANJA RASVJETOM? UGRADNJA FOTONAPONSKOG SUSTAVA COMP (Croatian)
0 references
A KÉT ÉPÜLET KÜLSŐ TÉRELHATÁROLÓJÁRA VONATKOZÓ JAVASOLT BEAVATKOZÁSOK A KÖVETKEZŐK:? FALSZIGETELÉS 4 CM KÜLSŐ BEVONATTAL?= 0,0015 W/MQ?K, HOGY A TELJES ÁTERESZTŐKÉPESSÉG KEVESEBB, MINT 0,24 W/MQ?K;? PADLÓK SZIGETELÉSE FŰTETLEN HELYISÉGEKBE (TÁROLÁS): 80 MM-ES INTRADOX SZIGETELŐ?=0,026 W/MQ?K, 0,24 W/MQ?K-NÁL KISEBB ÁTVITEL ELÉRÉSE ÉRDEKÉBEN;? SZIGETELJÜK AZ EXTRADOX A FELSŐ FÖDÉM FELÉ FŰTETLEN PADLÁS, EXTRUDÁLT HAB POLISZTIROL PANELEK 100 MM VASTAGSÁGÚ ÉS VEZETŐKÉPESSÉG? EGYENLŐ 0,026 W/MQ?K, HOGY A GLOBÁLIS ÁTVITEL KEVESEBB, MINT 0,24 W/MQ?K.? CSERETESTEK, ALACSONY KIBOCSÁTÁSÚAK, AMELYEK GLOBÁLIS ÁTERESZTŐKÉPESSÉGE KEVESEBB, MINT 1,0 W/MQ?K? DÍZELKAZÁN CSERÉJE TÁVFŰTÉSI HÁLÓZATI CSATLAKOZÁSSAL ÉS HŐSZIVATTYÚ TELEPÍTÉSSEL? ENERGIAFIGYELŐ RENDSZER TELEPÍTÉSE? VILÁGÍTÁSKEZELŐ RENDSZER TELEPÍTÉSE? A COMP FOTOVOLTAIKUS RENDSZER TELEPÍTÉSE (Hungarian)
0 references
SIŪLOMOS INTERVENCIJOS, SUSIJUSIOS SU ABIEJŲ PASTATŲ PASTATO APVALKALU, YRA ŠIOS: SIENŲ IZOLIACIJA SU 4 CM IŠORINIU SLUOKSNIU SU 0,0015 W/MQ?K, KAD BENDRAS PRALAIDUMAS BŪTŲ MAŽESNIS NEI 0,24 W/MQ?K;? GRINDŲ IZOLIACIJA NEŠILDOMUOSE KAMBARIUOSE (SANDĖLIAVIMAS): 80 MM INTRADOX IZOLIATORIUS SU?=0,026 W/MQ?K, KAD BŪTŲ PASIEKTAS MAŽESNIS NEI 0,24 W/MQ?K PRALAIDUMAS;? IZOLIUOTI AUKŠČIAUSIOS PLOKŠTĖS EKSTRADOKSAS Į NEŠILDOMĄ MANSARDĄ, SU EKSTRUZINIO PUTPLASČIO POLISTIRENO PLOKŠTĖMIS, KURIŲ STORIS IR LAIDUMAS YRA 100 MM? LYGUS 0,026 W/MQ?K, KAD BŪTŲ PASIEKTAS MAŽESNIS NEI 0,24 W/MQ?K VISUOTINIS PRALAIDUMAS? PAKAITINIAI ŠVIESTUVAI SU MAŽAI TERŠALŲ IŠMETANČIAIS ĮRENGINIAIS, KURIŲ VISUOTINIS PRALAIDUMAS MAŽESNIS NEI 1,0 W/MQ?K? DYZELINIO KATILO PAKEITIMAS CENTRALIZUOTO ŠILDYMO TINKLO PRIJUNGIMU IR ŠILUMOS SIURBLIŲ ĮRENGIMU? ENERGIJOS MONITORINGO SISTEMOS ĮRENGIMAS? APŠVIETIMO VALDYMO SISTEMOS ĮRENGIMAS? FOTOELEKTROS SISTEMOS ĮRENGIMAS COMP (Lithuanian)
0 references
IEROSINĀTIE INTERVENCES PASĀKUMI ATTIECĪBĀ UZ ĒKU NOROBEŽOJOŠĀM KONSTRUKCIJĀM ABĀS ĒKĀS IR ŠĀDI: SIENU IZOLĀCIJA AR 4 CM ĀRĒJO PĀRKLĀJUMU AR?= 0,0015 W/MQ?K, LAI SASNIEGTU KOPĒJO CAURLAIDĪBU, KAS MAZĀKA PAR 0,24 W/MQ?K;? GRĪDAS SILTINĀŠANA NEAPSILDĪTĀM TELPĀM (UZGLABĀŠANA): 80 MM INTRADOKSĀLS IZOLATORS AR?=0,026 W/MQ?K, LAI PANĀKTU CAURLAIDĪBU, KAS MAZĀKA PAR 0,24 W/MQ?K;? IZOLĒT AUGSTĀKĀS PLĀTNES EKSTRADOKSU PRET NEAPSILDĪTU BĒNIŅU, AR EKSTRUDĒTA PUTU POLISTIROLA PANEĻIEM, KURU BIEZUMS IR 100 MM UN VADĪTSPĒJA? VIENĀDS AR 0,026 W/MQ?K, LAI SASNIEGTU GLOBĀLO CAURLAIDĪBU, KAS MAZĀKA PAR 0,24 W/MQ?K? REZERVES ĶERMEŅI, AR ZEMU EMISIJU TIEM, KURU GLOBĀLĀ CAURLAIDĪBA IR MAZĀKA PAR 1,0 W/MQ?K? DĪZEĻDEGVIELAS KATLA NOMAIŅA AR CENTRALIZĒTĀS SILTUMAPGĀDES TĪKLA PIESLĒGUMU UN SILTUMSŪKŅU UZSTĀDĪŠANU? ENERĢIJAS MONITORINGA SISTĒMAS UZSTĀDĪŠANA? APGAISMOJUMA VADĪBAS SISTĒMAS UZSTĀDĪŠANA? FOTOELEMENTU SISTĒMAS UZSTĀDĪŠANA COMP (Latvian)
0 references
L-INTERVENTI PROPOSTI LI JIKKONĊERNAW L-INVOLUKRU TAL-BINI TAŻ-ŻEWĠ BINJIET HUMA:? INSULAZZJONI TAL-ĦAJT B’KISJA TA ‘BARRA 4 CM MA’? = 0.0015 W/MQ?K BIEX TINKISEB TRAŻMISSJONI GLOBALI TA ‘INQAS MINN 0.24 W/MQ?K;? IŻOLAMENT TAL-ART FI KMAMAR MHUX IMSAĦĦNA (ĦŻIN): 80 MM IŻOLATUR INTRADOX MA?=0.026 W/MQ?K, BIEX TINKISEB TRASMISSJONI TA ‘INQAS MINN 0.24 W/MQ?K;? INSULATE L-ESTRADOSS TAĊ-ĊANGATURA SUPERJURI LEJN ATTIC MHUX IMSAĦĦAN, B’PANNELLI TAL-POLISTIRENE TAL-FOWM ESTRUŻ TA’ ĦXUNA U KONDUTTIVITÀ TA’ 100 MM? UGWALI GĦAL 0.026 W/MQ?K, SABIEX TINKISEB TRAŻMISSJONI GLOBALI TA ‘INQAS MINN 0.24 W/MQ?K.? TAGĦMIR TA’ SOSTITUZZJONI, B’EMISSJONIJIET BAXXI BI TRAŻMISSJONI GLOBALI INQAS MINN 1.0 W/MQ?K? SOSTITUZZJONI TAL-BOJLER TAD-DIŻIL B’KONNESSJONI TAN-NETWERK TAT-TISĦIN DISTRETTWALI U INSTALLAZZJONI TAL-POMPA TAS-SĦANA? INSTALLAZZJONI TA’ SISTEMA TA’ MONITORAĠĠ TAL-ENERĠIJA? INSTALLAZZJONI TA’ SISTEMA TA’ ĠESTJONI TAD-DAWL? INSTALLAZZJONI TA’ SISTEMA FOTOVOLTAJKA COMP (Maltese)
0 references
DE VOORGESTELDE INTERVENTIES MET BETREKKING TOT DE BOUWSCHIL VAN BEIDE GEBOUWEN ZIJN: WANDISOLATIE MET 4 CM BUITENLAAG MET?= 0,0015 W/MQ?K OM EEN TOTALE TRANSMISSIE TE BEREIKEN VAN MINDER DAN 0,24 W/MQ?K;? ISOLATIE VAN VLOEREN TOT ONVERWARMDE RUIMTES (OPSLAG): 80 MM INTRADOX-ISOLATOR MET? = 0,026 W/MQ?K, OM EEN TRANSMISSIE TE BEREIKEN VAN MINDER DAN 0,24 W/MQ?K;? ISOLEREN DE EXTRADOX VAN DE SUPERIEURE PLAAT NAAR ONVERWARMDE ZOLDER, MET GEËXTRUDEERD SCHUIM POLYSTYREEN PANELEN VAN 100 MM DIKTE EN GELEIDBAARHEID? GELIJK AAN 0,026 W/MQ?K, OM EEN WERELDWIJDE TRANSMISSIE TE BEREIKEN VAN MINDER DAN 0,24 W/MQ?K.? VERVANGINGSARMATUREN, MET EEN LAGE EMISSIE MET EEN WERELDWIJDE TRANSMISSIE VAN MINDER DAN 1,0 W/MQ?K? VERVANGING VAN DIESELKETEL DOOR STADSVERWARMINGSNETAANSLUITING EN WARMTEPOMPINSTALLATIE? INSTALLATIE VAN ENERGIEBEWAKINGSSYSTEEM? INSTALLATIE VAN VERLICHTINGSMANAGEMENTSYSTEEM? INSTALLATIE VAN FOTOVOLTAÏSCHE SYSTEEM COMP (Dutch)
0 references
AS INTERVENÇÕES PROPOSTAS RELATIVAS À INTRODUÇÃO DE EDIFÍCIOS EM TODOS OS EDIFÍCIOS SÃO:? INSULAÇÃO DE PAREDE COM CASA EXTERIOR DE 4 CM COM ?= 0,0015 W/MQ?K PARA REALIZAR UMA TRANSMITÊNCIA GLOBAL INFERIOR A 0,24 W/MQ?K;? INSULAÇÃO DE PAVIMENTOS EM QUARTOS NÃO AQUECIDOS (ARMAZENAMENTO): 80 MM INTRADOX INSULATOR COM?=0,026 W/MQ?K, PARA REALIZAR UMA TRANSMITÊNCIA INFERIOR A 0,24 W/MQ?K;? INSULAR O EXTRADOXO DA TABELA SUPERIOR PARA ÁTICO NÃO MELHORADO, COM PANÉIS EXTRUDIDOS DE POLISTIRENO DE ALMA DE 100 MM DE ESPESSURA E CONDUTIVIDADE? Igual a 0,026 W/MQ?K, de modo a alcançar uma transmissão global inferior a 0,24 W/MQ?K.? FIXAÇÕES DE SUBSTITUIÇÃO, COM LINHAS DE EMISSÕES COM TRANSMITÊNCIA GLOBAL INFERIOR A 1,0 W/MQ?K? Substituição da caldeira a diesel por uma ligação à rede de aquecimento distrital e instalação de bombas de calor? INSTALAÇÃO DO SISTEMA DE MONITORIZAÇÃO ENERGÉTICA? INSTALAÇÃO DO SISTEMA DE GESTÃO DA ILUMINAÇÃO? INSTALAÇÃO DO SISTEMA FOTOVOLTÁTICO COMP (Portuguese)
0 references
INTERVENȚIILE PROPUSE PRIVIND ANVELOPA DE CONSTRUCȚIE A AMBELOR CLĂDIRI SUNT:? IZOLAȚIE DE PERETE CU STRAT EXTERIOR DE 4 CM CU 0.0015 W/MQ?K PENTRU A OBȚINE O TRANSMISIE GLOBALĂ MAI MICĂ DE 0,24 W/MQ?K;? IZOLAREA PODELELOR ÎN ÎNCĂPERI NEÎNCĂLZITE (DEPOZITARE): IZOLATOR INTRADOX DE 80 MM CU 0,026 W/MQ?K, PENTRU A OBȚINE O TRANSMISIE MAI MICĂ DE 0,24 W/MQ?K;? IZOLAȚI EXTRADOXUL PLĂCII SUPERIOARE SPRE MANSARDA NEÎNCĂLZITĂ, CU PANOURI EXTRUDATE DIN POLISTIREN DE 100 MM GROSIME ȘI CONDUCTIVITATE? EGAL CU 0.026 W/MQ?K, ASTFEL ÎNCÂT SĂ SE OBȚINĂ O TRANSMISIE GLOBALĂ MAI MICĂ DE 0,24 W/MQ?K.? CORPURI DE SCHIMB, CU EMISII SCĂZUTE, CU TRANSMISIE GLOBALĂ MAI MICĂ DE 1,0 W/MQ?K? ÎNLOCUIREA CAZANULUI DIESEL CU RACORDAREA LA REȚEAUA DE ÎNCĂLZIRE CENTRALIZATĂ ȘI INSTALAREA POMPEI DE CĂLDURĂ? INSTALAREA SISTEMULUI DE MONITORIZARE A ENERGIEI? INSTALAREA SISTEMULUI DE MANAGEMENT AL ILUMINATULUI? INSTALAREA SISTEMULUI FOTOVOLTAIC COMP (Romanian)
0 references
NAVRHOVANÉ ZÁSAHY TÝKAJÚCE SA PLÁŠŤA BUDOV OBOCH BUDOV SÚ:? IZOLÁCIA STIEN S VONKAJŠÍM PLÁŠŤOM 4 CM S?= 0,0015 W/MQ?K NA DOSIAHNUTIE CELKOVEJ PRIEPUSTNOSTI MENEJ AKO 0,24 W/MQ?K;? IZOLÁCIA PODLÁH DO NEVYKUROVANÝCH MIESTNOSTÍ (SKLADOVANIE): 80 MM INTRADOXOVÝ IZOLÁTOR S?=0,026 W/MQ?K, NA DOSIAHNUTIE PRIEPUSTNOSTI MENŠEJ AKO 0,24 W/MQ?K;? IZOLOVAŤ EXTRADOX VYNIKAJÚCEJ DOSKY SMEROM K NEVYKUROVANÉMU PODKROVÍ, S EXTRUDOVANÝMI PENOVÝMI POLYSTYRÉNOVÝMI PANELMI S HRÚBKOU 100 MM A VODIVOSŤOU? ROVNÁ SA 0,026 W/MQ?K, ABY SA DOSIAHLA GLOBÁLNA PRIEPUSTNOSŤ MENEJ AKO 0,24 W/MQ?K.? NÁHRADNÉ SVIETIDLÁ S NÍZKYMI EMISIAMI S GLOBÁLNOU PRIEPUSTNOSŤOU MENŠOU AKO 1,0 W/MQ?K? VÝMENA NAFTOVÉHO KOTLA ZA PRIPOJENIE SIETE DIAĽKOVÉHO VYKUROVANIA A INŠTALÁCIU TEPELNÝCH ČERPADIEL? INŠTALÁCIA SYSTÉMU MONITOROVANIA ENERGIE? INŠTALÁCIA SYSTÉMU RIADENIA OSVETLENIA? INŠTALÁCIA FOTOVOLTAICKÉHO SYSTÉMU COMP (Slovak)
0 references
PREDLAGANI UKREPI V ZVEZI Z OVOJEM STAVB OBEH STAVB SO: STENSKA IZOLACIJA Z ZUNANJIM SLOJEM 4 CM Z?= 0,0015 W/MQ?K, DA SE DOSEŽE SPLOŠNA PREPUSTNOST MANJ KOT 0,24 W/MQ?K;? IZOLACIJA TAL V NEOGREVANE PROSTORE (SKLADIŠČENJE): 80 MM IZOLATOR INTRADOKSA Z?=0,026 W/MQ?K, DA SE DOSEŽE PREPUSTNOST MANJ KOT 0,24 W/MQ? IZOLIRATI EKSTRADOKS VRHUNSKE PLOŠČE PROTI NEOGREVANEMU PODSTREŠJU, Z EKSTRUDIRANIMI POLISTIRENSKIMI PLOŠČAMI DEBELINE 100 MM IN PREVODNOSTI? ENAKO 0,026 W/MQ?K, DA BI DOSEGLI GLOBALNO PREPUSTNOST MANJ KOT 0,24 W/MQ? NADOMESTNE NAPELJAVE Z NIZKIMI EMISIJAMI Z GLOBALNO PREPUSTNOSTJO MANJ KOT 1,0 W/MQ?K? ZAMENJAVA DIZELSKEGA KOTLA Z OMREŽNIM PRIKLJUČKOM ZA DALJINSKO OGREVANJE IN NAMESTITVIJO TOPLOTNIH ČRPALK? NAMESTITEV SISTEMA ZA SPREMLJANJE ENERGIJE? NAMESTITEV SISTEMA ZA UPRAVLJANJE RAZSVETLJAVE? NAMESTITEV FOTONAPETOSTNEGA SISTEMA COMP (Slovenian)
0 references
DE FÖRESLAGNA INSATSERNA FÖR BÅDA BYGGNADERNAS KLIMATSKAL ÄR FÖLJANDE:? VÄGGISOLERING MED 4 CM YTTERSKIKT MED?= 0.0015 W/MQ?K FÖR ATT UPPNÅ EN TOTAL TRANSMITTANS PÅ MINDRE ÄN 0,24 W/MQ?K;? ISOLERING AV GOLV TILL OUPPVÄRMDA RUM (LAGRING): 80 MM INTRADOX ISOLATOR MED?=0.026 W/MQ?K, FÖR ATT UPPNÅ EN TRANSMITTANS PÅ MINDRE ÄN 0,24 W/MQ?K;? ISOLERA DEN ÖVERLÄGSNA PLATTANS EXTRADOXA MOT OUPPVÄRMD VIND, MED EXTRUDERADE SKUMPOLYSTYRENPANELER MED 100 MM TJOCKLEK OCH KONDUKTIVITET? LIKA MED 0,026 W/MQ?K, FÖR ATT UPPNÅ EN GLOBAL TRANSMITTANS PÅ MINDRE ÄN 0,24 W/MQ?K.? ERSÄTTNINGSARMATURER MED LÅGA UTSLÄPP MED GLOBAL TRANSMITTANS MINDRE ÄN 1,0 W/MQ?K? ERSÄTTNING AV DIESELPANNA MED FJÄRRVÄRMENÄTSANSLUTNING OCH VÄRMEPUMPSINSTALLATION? INSTALLATION AV ENERGIÖVERVAKNINGSSYSTEM? INSTALLATION AV BELYSNINGSSYSTEM? INSTALLATION AV SOLCELLSSYSTEM COMP (Swedish)
0 references
CAREGGINE
0 references
10 April 2023
0 references