Wastewater management in Garwollines (Q85283): Difference between revisions
Jump to navigation
Jump to search
(Changed an Item) |
(Changed an Item) |
||
Property / beneficiary | |||
Property / beneficiary: Q2514619 / rank | |||
Normal rank |
Revision as of 19:16, 9 June 2020
Project in Poland financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | Wastewater management in Garwollines |
Project in Poland financed by DG Regio |
Statements
22,597,001.49 zloty
0 references
50,313,109.43 zloty
0 references
85.0 percent
0 references
1 January 2014
0 references
31 December 2018
0 references
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ
0 references
Oczyszczalnia ścieków nie spełnia jakości ścieków oczyszczonych w zakresie azotu. Parametry azotu w uśrednionych badaniach za rok 2014 wynosiły 38,2 mg/l > 15 mg/l. Zakres modernizacji OŚ: rozbudowa i przebudowa części mechanicznej i biologicznej oczyszczalni ścieków;instalacja do przygotowania osadów do fermentacji – autotermiczna hydroliza; rozbudowa i przebudowa części osadowej oczyszczalni ścieków; instalacja biogazu; suszarnia niskotemperaturowa osadu. W ramach modernizacji OŚ zwiększana będzie również jej przepustowość do 41 250 RLM, co wynika z aktualnych potrzeb i dopływającego ładunku zanieczyszczeń. Dodatkowo w ramach projektu będzie realizowana: - budowa sieci kanalizacyjnej w ul. Andersa, Sławińska, Cicha, Maczka - 3,25 km - renowacja sieci kanalizacyjnej - 3,21 km, - budowa sieci kanalizacji deszczowej - 0,32km. (Polish)
0 references
The waste water treatment plant does not meet the quality of wastewater treated in the nitrogen range.The nitrogen parameters at the averaged 2014 tests were 38.2 mg/l > 15 mg/l.extension and reconstruction of the mechanical and biological parts of the waste water treatment plant; the installation for the preparation of the digestion sludge — the autothermal hydrolysis;extension and reconstruction of the sewage treatment plant portion of the sewage treatment plant;biogas plant;drying oven for low temperature sediment.As part of the modernisation process, the EP will also increase its capacity to 41 250 p.e., due to the current needs and the incoming load of the pollutants.In addition, the project will implement:Construction of the sewage system at ul.Anders, Słańska, cich, Maków — 3.25 km — renovation of the sewage network — 3.21 km — construction of the rainwater drainage network — 0.32 km. (English)
0 references
Identifiers
POIS.02.03.00-00-0072/16
0 references