Revision as of 00:29, 9 June 2020
Project in Italy financed by DG Regio
Language | Label | Description | Also known as |
---|---|---|---|
English | (A19_093_2016_0930012_1011) EE WINDOW |
Project in Italy financed by DG Regio |
Statements
55,883.75 Euro
0 references
111,767.5 Euro
0 references
50.0 percent
0 references
1 August 2016
0 references
21 December 2018
0 references
11 January 2019
0 references
E.S.TR.A. S.P.A. ENERGIA SERVIZI TERRITORIO AMBIENTE
0 references
L'INTERVENTO PREVEDE INIZIALMENTE LO SMANTELLAMENTO COMPLETO DELLE 62 POMPE DI CALORE E DEI RELATIVI CIRCOLATORI TRADIZIONALI PRESENTI SULLA COPERTURA DELL'EDIFICIO. VERRANNO POI INSTALLATE, SU UNA NUOVA PLATEA NELLA ZONA DEI PARCHEGGI DELL'EDIFICIO, DUE POMPE DI CALORE SILENZIATE AD ALTA EFFICIENZA DA 363 KWF E 404 KWT TERMICI CIASCUNA. TALI MACCHINE VERRANNO COLLEGATE IDRAULICAMENTE IN PARALLELO E TRAMITE UNA TUBAZIONE INTERRATA E UN CIRCOLATORE GEMELLARE AD INVERTER, UNO PER MACCHINA, SARANNO COLLEGATE AD UN ACCUMULO INERZIALE CHE SEPARERA IL CIRCUITO PRIMARIO DALLA DISTRIBUZIONE DELL'IMPIANTO DI CLIMATIZZAZIONE DELL'EDIFICIO. IL SERBATOIO INERZIALE, INSTALLATO ALL'INTERNO DI UN NUOVO LOCALE TECNICO REALIZZATO ALL'INTERNO DI UN MAGAZZINO DELL'EDIFICIO IN PROSSIMITA DELLE DUE POMPE DI CALORE, AVRA LA DUPLICE FUNZIONE DI DISCONNETTORE IDRAULICO E DI VOLANO TERMICO. DALL'ACCUMULO INERZIALE SI SVILUPPERA POI IL NUOVO CIRCUITO DI DISTRIBUZIONE PRINCIPALE CHE, TRAMITE UN NUOVO CIRCOLATORE (Italian)
0 references
THE INTERVENTION INITIALLY FORESEES THE COMPLETE DISMANTLING OF THE 62 HEAT PUMPS AND THE ASSOCIATED TRADITIONAL CIRCULATORS ON THE BUILDING’S COVERAGE. TWO HIGHLY EFFICIENT 363 KWF AND 404 KWT THERMAL HEAT PUMPS EACH WILL BE INSTALLED ON A NEW FLOOR IN THE BUILDING PARKING AREA OF THE BUILDING. THESE MACHINES WILL BE CONNECTED IN PARALLEL WITH THE RUNNING OF AN UNDERGROUND PIPE AND A TWIN (TWINNING) TO TWIN, ONE PER MACHINE, WILL BE CONNECTED TO AN INERTIAL ACCUMULATION WHICH ARE CONNECTED TO THE PRIMARY CIRCUIT BY THE DISTRIBUTION OF THE AIR-CONDITIONING SYSTEM IN THE BUILDING. THE INERTIAL TANK, INSTALLED INSIDE A NEW TECHNICAL ROOM MADE WITHIN A BUILDING WAREHOUSE IN THE VICINITY OF THE TWO HEAT PUMPS, HAD THE DUAL FUNCTION OF DISTRIBUTED HYDRAULIC AND FLYWHEEL THERMAL POWER. FROM ACCUMULATED INERTIAL ACCUMULATION, THE NEW MAIN DISTRIBUTION CIRCUIT WHICH, THROUGH A NEW CIRCULATOR (English)
0 references
Identifiers
D58I16002090009
0 references