Energy modernisation of Héhalom municipal building (Q3951155): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Changed an Item: Adding French translations)
(‎Removed claims)
Property / co-financing rate
84.999987 percent
Amount84.999987 percent
Unitpercent
 
Property / co-financing rate: 84.999987 percent / rank
Normal rank
 
Property / EU contribution
83,678.13 Euro
Amount83,678.13 Euro
UnitEuro
 
Property / EU contribution: 83,678.13 Euro / rank
Preferred rank
 
Property / EU contribution: 83,678.13 Euro / qualifier
exchange rate to Euro: 0.00276521 Euro
Amount0.00276521 Euro
UnitEuro
 
Property / EU contribution: 83,678.13 Euro / qualifier
point in time: 6 December 2021
Timestamp+2021-12-06T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0
 
Property / EU contribution
30,261,040 forint
Amount30,261,040 forint
Unitforint
 
Property / EU contribution: 30,261,040 forint / rank
Normal rank
 
Property / budget
97,320.416 Euro
Amount97,320.416 Euro
UnitEuro
 
Property / budget: 97,320.416 Euro / rank
Preferred rank
 
Property / budget: 97,320.416 Euro / qualifier
exchange rate to Euro: 0.0027336256 Euro
Amount0.0027336256 Euro
UnitEuro
 
Property / budget: 97,320.416 Euro / qualifier
point in time: 15 December 2021
Timestamp+2021-12-15T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0
 
Property / budget
35,601,223.529 forint
Amount35,601,223.529 forint
Unitforint
 
Property / budget: 35,601,223.529 forint / rank
Normal rank
 

Revision as of 17:02, 13 February 2022

Project Q3951155 in Hungary
Language Label Description Also known as
English
Energy modernisation of Héhalom municipal building
Project Q3951155 in Hungary

    Statements

    0 references
    1 April 2018
    0 references
    29 December 2020
    0 references
    HÉHALOM KÖZSÉG ÖNKORMÁNYZATA
    0 references
    Q3979275 (Deleted Item)
    0 references

    47°46'1.99"N, 19°35'38.72"E
    0 references
    A projekt megvalósítási időszakában, egy képzés keretében a beruházással érintett épület használói tájékoztatásban részesülnek (az alkalmazott megoldásokról, a helyes üzemeltetés szabályairól, valamint a beruházás környezeti hozadékairól), melyet a tervek szerint épületenergetikában jártas szakértő végez majd. Az előadott képzési anyagot az adott intézményen belül elérhetővé is tesszük. A projekt teljes megvalósítási időszakában egy energetikai szakértő is bevonásra kerül, az alábbi feladatokkal: - a kivitelezés közbeszerzési eljárás során energetikai kérdésekben szakmai konzultáció és tanácsadás a közbeszerzési eljárást lefolytató szakértő számára (pl. a kivitelezés energetikai vonatkozású műszaki kérdéseiről) - energetikai szakértői konzultáció biztosítása a pályázó képviselőjével és a bevonásra került műszaki ellenőrrel (pl. a beépített anyagok energetikai megfelelőségéről) - projekt fizikai befejezését követően záró energetikai auditori vizsgálat és tanúsítvány készítése. Emellett a projekt energetikai beruházásának kivitelezésével párhuzamosan energetikai szakértői szolgáltatás keretében felmérésre és vizsgálatra kerülnek a település intézményeinek épületenergetikai paraméterei, majd az adatfeldolgozás után ezek rögzítésre kerülnek NÉeR-ben. A felmérés célja, hogy egy későbbi térségi vagy megyei SEAP vagy SECAP tanulmány előkészítése során ezek a rögzített adatok strukturáltan, bázisadatként már rendelkezésre álljanak. A fejlesztés során Héhalom Község Önkormányzat Óvoda épülete kerül korszerűsítésre. Nyílászáró-csere A nyílászárók cseréje a 7/2006 TNM rendelet 5. mellékletének, azaz a költségoptimalizált követelményszintnek megfelelően szükséges (a követelményértékek a határoló szerkezetre vonatkozó javaslat után kiemelve megtalálhatóak). A meglévő (energetikai paramétereiben a követelményektől elmaradó) homlokzati nyílászárók cseréje Uwmax = 1,15 W/m2K hőátbocsátási tényezőjű nyílászárókra, a szükséges bontásokkal, helyreállításokkal és rendszer-kiegészítőkkel együtt. A korszerű, jó légzárású nyílászárók beépítése alacsonyabb légcsere számot és így friss levegő hiányt, páratechnikai problémákat okozhat. Ennek kiküszöbölésére a nyílászárókba páraszabályzott (valamint gázüzemű készüléket tartalmazó helyiségek esetén fix) légbeeresztők beépítését javasoljuk. Utólagos külső oldali hőszigetelések Az utólagos külső oldali hőszigetelések kialakítása a 7/2006 TNM rendelet 5. mellékletének, azaz a költségoptimalizált követelményszintnek megfelelően szükséges. A homlokzati falak hőszigetelése 15 cm vtg., ?=0,04 W/mK hővezetési tényező értékkel rendelkező kőzetgyapot hőszigetelő (kő fal miatt kell kőzetgyapot) rendszer alkalmazásával, a szükséges bontásokkal, helyreállításokkal és rendszer-kiegészítőkkel együtt, hőhídmentes (vagy maximum 0,002 W/K pontszerű hőhídveszteségi tényezőjű) műanyag dűbelezéssel. Padlásfödém hőszigetelése 25 cm vtg., ?=0,04 W/mK hővezetési tényező értékkel rendelkező üveggyapot hőszigetelő rendszer alkalmazásával. Épületgépészeti korszerűsítések Az épületben található korszerűtlen, állandó hőmérsékletű gázkazán cseréje kondenzációs gázkazánra, automatikával programozható fűtésszabályozással ellátva, valamint a teljesítmény és a hőigény pontatlansága miatti veszteségek csökkentése érdekében termosztatikus radiátorszelepek beszerelése. A jelenlegi használati meleg víz készítő berendezések cseréje, korszerűsítése költséghatékonysági okokból nem indokolt, az alacsony meleg víz fogyasztás miatt. Megújuló energia alapú rendszerek Az épület villamos energia fogyasztásának csökkentése/kiváltása érdekében hálózatra visszatápláló napelemes rendszer telepítése az alábbi paraméterekkel: A tervezett rendszer jellemzői: Csúcsteljesítmény (becsült): 5,5 kWp Fajlagos energiahozam (becsült): 965 kWh/kWp Éves energiahozam (becsült): 5310 kWh/év A kalkuláció 275 Wp csúcsteljesítményű polikristályos napelem modulokkal történt, a rendszernek tartalmaznia kell az áramszolgáltató által elfogadott invertereket, a napelemek tetőre rögzítéséhez szükséges tartószerkezeteket, egyen-, és váltakozó áram oldali túlfeszültség védelmeket. Megvalósítás során a pályázati előírásoknak megfelelően projektarányos akadálymentesítésre kerül sor. A tervezett projekt illeszkedik a Nemzeti Energiastratégia 2030, Magyarország II. Nemzeti Energiahatékonysági Cselekvési Terv, ill. Nemzeti Épületenergetikai Stratégiában megfogalmazottakhoz. A beruházás hozzájárul az önkormányzatok által működtetett intézmények ÜHG-kibocsátásának csökkentéséhez (Hungarian)
    0 references
    During the implementation period of the project, as part of a training course, the users of the building affected by the investment will receive information (on the solutions applied, the rules of proper operation and the environmental benefits of the project) which is planned to be carried out by an expert with experience in building energy. The training material presented will also be made available within the relevant institution. An energy expert will be involved throughout the project implementation period, with the following tasks: — professional consultation and advice on energy issues for the expert conducting the public procurement procedure during the construction procurement procedure (e.g. on the energy-related technical issues of construction) — provision of energy expert consultation with the representative of the applicant and the technical inspector involved (e.g. on the energy compliance of the built-in materials) — preparation of final energy audit and certification after the physical completion of the project. In addition, in parallel with the implementation of the project’s energy project, the building energy parameters of the institutions of the settlement will be assessed and tested in the framework of an energy expert service, and after the data processing they will be recorded in the NÉeR. The aim of the survey is to ensure that these recorded data are already available in a structured way as base data during the preparation of a future regional or county SEAP or SECAP study. In the course of the development, the nursery building of the Municipality of Héhalom will be upgraded. Replacement of doors and windows is necessary in accordance with Annex 5 of Decree No 7/2006, i.e. the cost-optimal requirement level (the criteria values can be found after the proposal for the delimitation structure). Replacement of existing facade doors and windows (which are below the requirements in its energy parameters) for windows with a heat transfer factor Uwmax = 1.15 W/m2K, together with necessary demolitions, restorations and system accessories. The installation of modern, well-sealed doors and windows can cause a lower number of air exchange and thus a lack of fresh air and humidity problems. In order to avoid this, we recommend the installation of air inlets that are vapor-controlled (and fixed in the case of rooms with gas-fired appliances). Retrospective external thermal insulation The design of ex-post thermal insulation on the external side is necessary in accordance with Annex 5 of Decree No 7/2006, i.e. the cost-optimal requirement level. The thermal insulation of facade walls is made of 15 cm vtg.,?=0.04 W/mK thermal conductivity factor, using a thermal insulation system (the stone wall requires rock wool) together with the necessary demolitions, restorations and system accessories, with a non-heat bridge (or maximum heat bridge loss factor of 0.002 W/K) plastic ensemble. Thermal insulation of the attic ceiling using a thermal insulation system of 25 cm vtg.,?=0.04 W/mK thermal conductivity factor. Replacement of an outdated, constant temperature gas boiler in the building for a condensation gas boiler with automatic programmable heating control and the installation of thermostatic radiator valves to reduce losses due to inaccuracy of performance and heat demand. The replacement and modernisation of the current domestic hot water production equipment is not justified for reasons of cost-effectiveness due to low hot water consumption. Renewable energy-based systems Installing a solar system regenerating to the grid to reduce/replace electricity in the building, with the following parameters: Characteristics of the intended system: Peak performance (estimated): 5,5 kWp Average energy yield (estimated): 965 kWh/kWp Annual energy yield (estimated): 5 310 kWh/year The calculation has been made with polycrystalline solar modules with a peak power of 275 Wp, the system shall include the inverters accepted by the power supplier, the support structures needed to attach the solar panels to the roof, the DC and AC overvoltage protections. During implementation, in accordance with the specifications of the project, the accessibility of the project will be carried out. The planned project fits the National Energy Strategy 2030, Hungary II. National Energy Efficiency Action Plan and National Building Energy Strategy. The investment contributes to the reduction of GHG emissions from institutions run by municipalities (English)
    9 February 2022
    0 references
    Au cours de la période de mise en œuvre du projet, dans le cadre d’une formation, les utilisateurs du bâtiment concerné par l’investissement recevront des informations (sur les solutions appliquées, les règles de bon fonctionnement et les avantages environnementaux du projet) qui seront réalisées par un expert ayant une expérience de l’énergie du bâtiment. Le matériel de formation présenté sera également mis à disposition au sein de l’institution concernée. Un expert en énergie sera associé tout au long de la période de mise en œuvre du projet, avec les tâches suivantes: — consultation professionnelle et conseils sur les questions énergétiques à l’intention de l’expert qui conduit la procédure de passation de marché pendant la procédure de passation de marché (par exemple, sur les questions techniques liées à l’énergie de la construction) — fourniture d’une consultation d’expert en énergie avec le représentant du demandeur et l’inspecteur technique concerné (par exemple, sur la conformité énergétique des matériaux incorporés) — préparation de l’audit énergétique final et de la certification après l’achèvement physique du projet. En outre, parallèlement à la mise en œuvre du projet énergétique du projet, les paramètres énergétiques du bâtiment des institutions du règlement seront évalués et testés dans le cadre d’un service d’experts en énergie, et après traitement des données, ils seront enregistrés dans le NÉeR. L’objectif de l’enquête est de s’assurer que ces données enregistrées sont déjà disponibles de manière structurée en tant que données de base lors de la préparation d’une future étude SEAP ou SECAP régionale ou départementale. Dans le cadre du développement, le bâtiment de la pépinière de la municipalité d’Héhalom sera modernisé. Le remplacement des portes et des fenêtres est nécessaire conformément à l’annexe 5 du décret no 7/2006, c’est-à-dire le niveau d’exigence optimale en fonction des coûts (les valeurs des critères peuvent être trouvées après la proposition de structure de délimitation). Remplacement des portes et fenêtres de façade existantes (qui sont inférieures aux exigences de ses paramètres énergétiques) pour les fenêtres par un facteur de transfert de chaleur Uwmax = 1,15 W/m2K, ainsi que les démolitions, les restaurations et les accessoires du système nécessaires. L’installation de portes et de fenêtres modernes et bien scellées peut entraîner une diminution du nombre d’échanges d’air et donc un manque d’air frais et de problèmes d’humidité. Pour éviter cela, nous recommandons l’installation d’entrées d’air commandées par la vapeur (et fixées dans le cas des locaux équipés d’appareils à gaz). Isolation thermique externe rétrospective La conception de l’isolation thermique ex post du côté extérieur est nécessaire conformément à l’annexe 5 du décret no 7/2006, c’est-à-dire le niveau d’exigence optimal en fonction des coûts. L’isolation thermique des murs de façade est faite de 15 cm vtg.,?=0,04 W/mK facteur de conductivité thermique, à l’aide d’un système d’isolation thermique (le mur de pierre nécessite de la laine de roche) ainsi que les démolitions, les restaurations et les accessoires du système nécessaires, avec un pont non thermique (ou facteur de perte de pont thermique maximal de 0,002 W/K) ensemble en plastique. Isolation thermique du plafond grenier à l’aide d’un système d’isolation thermique de 25 cm vtg.,?=0,04 W/mK facteur de conductivité thermique. Remplacement d’une chaudière à gaz à température constante et désuète dans le bâtiment pour une chaudière à gaz à condensation par une commande de chauffage programmable automatique et l’installation de vannes de radiateur thermostatiques pour réduire les pertes dues à l’inexactitude de la performance et de la demande de chaleur. Le remplacement et la modernisation des équipements actuels de production d’eau chaude domestique ne se justifient pas pour des raisons de rentabilité en raison de la faible consommation d’eau chaude. Systèmes basés sur les énergies renouvelables Installation d’un système solaire régénérant au réseau pour réduire/remplacer l’électricité dans le bâtiment, avec les paramètres suivants: Caractéristiques du système prévu: Performance maximale (estimée): 5,5 kWp Rendement énergétique moyen (estimé): 965 kWh/kWp Rendement énergétique annuel (estimé): 5 310 kWh/an Le calcul a été effectué avec des modules solaires polycristallins d’une puissance maximale de 275 Wp, le système doit inclure les onduleurs acceptés par le fournisseur d’énergie, les structures de support nécessaires pour fixer les panneaux solaires au toit, les protections contre les surtensions CC et AC. Au cours de la mise en œuvre, conformément aux spécifications du projet, l’accessibilité du projet sera réalisée. Le projet prévu correspond à la stratégie énergétique nationale 2030, Hongrie II. Plan d’action national pour l’efficacité énergétique et stratégie nationale pour l’énergie des bâtiments. L’investissement contribue à la ... (French)
    10 February 2022
    0 references
    Héhalom, Nógrád
    0 references

    Identifiers

    TOP-3.2.1-16-NG1-2017-00005
    0 references